Abstract
Critical hypoxemia soon after birth is the most critical preoperative determinant of neurological outcomes and survival in newborns with Dextro Transposition of the Great Arteries and Intact Ventricular Septum (D-TGAIVS). Our study aimed to define fetal echocardiographic aspects that can better predict neonates with D-TGAIVS at risk for restricted interatrial communication after birth. 31 fetuses with a prenatal diagnosis of D-TGAIVS were included in our study. We divided patients with D-TGAIVS according to the timing of balloon atrial septostomy: Urgent, Not-Urgent and no BAS. We identified five fetal echocardiographic aspects of the interatrial septum (redundant, aneurysmal, flat, fixed, hypermobile). No significant differences in these fetal echocardiographic features were found between the three different groups of D-TGAIVS according to the timing of balloon atrial septostmy. However, only two patients showed flat appearance of interatrial communication: both needed Urgent balloon atrial septostomy. The prevalence of hypermobile septum primum was significantly lower in the control group compared to patients with D-TGAIVS. Fetal echocardiographic aspects cannot predict patients with D-TGAIVS who will not need Urgent balloon atrial septostomy. Therefore, we recommended a delivery in a tertiary center, equipped for Urgent balloon atrial septostomy, for all patients with D-TGAIVS regardless of fetal echocardiographic features.
Similar content being viewed by others
References
Calderon J, Angeard N, Moutier S, Plumet M-H, Jambaqué I, Bonnet D (2012) Impact of prenatal diagnosis on neurocognitive outcomes in children with transposition of the great arteries. J Pediatr 161(1):94-98.e1
Blyth M, Howe D, Gnanapragasam J, Wellesley D (2008) The hidden mortality of transposition of the great arteries and survival advantage provided by prenatal diagnosis. BJOG Int J Obstet Gynaecol 115(9):1096–1100
Bonnet D, Coltri A, Butera G, Fermont L, Le Bidois J, Kachaner J et al (1999) Detection of transposition of the great arteries in fetuses reduces neonatal morbidity and mortality. Circulation 99(7):916–918
van Velzen CL, Haak MC, Reijnders G, Rijlaarsdam MEB, Bax CJ, Pajkrt E et al (2015) Prenatal detection of transposition of the great arteries reduces mortality and morbidity. Ultrasound Obstet Gynecol 45(3):320–325
Kumar RK, Newburger JW, Gauvreau K, Kamenir SA, Hornberger LK (1999) Comparison of outcome when hypoplastic left heart syndrome and transposition of the great arteries are diagnosed prenatally versus when diagnosis of these two conditions is made only postnatally. Am J Cardiol 83(12):1649–1653
Maeno YV, Kamenir SA, Sinclair B, van der Velde ME, Smallhorn JF, Hornberger LK (1999) Prenatal features of ductus arteriosus constriction and restrictive foramen ovale in d-transposition of the great arteries. Circulation 99(9):1209–1214
Jouannic J-M, Gavard L, Fermont L, Le Bidois J, Parat S, Vouhé PR et al (2004) Sensitivity and specificity of prenatal features of physiological shunts to predict neonatal clinical status in transposition of the great arteries. Circulation 110(13):1743–1746
Soongswang J, Adatia I, Newman C, Smallhorn JF, Williams WG, Freedom RM (1998) Mortality in potential arterial switch candidates with transposition of the great arteries. J Am Coll Cardiol settembre 32(3):753–757
Punn R, Silverman NH (2011) Fetal predictors of urgent balloon atrial septostomy in neonates with complete transposition. J Am Soc Echocardiogr 24(4):425–430
Vigneswaran TV, Zidere V, Miller OI, Simpson JM, Sharland GK (2017) Usefulness of the prenatal echocardiogram in fetuses with isolated transposition of the great arteries to predict the need for balloon atrial septostomy. Am J Cardiol 119(9):1463–1467
Tuo G, Paladini D, Montobbio G, Volpe P, Cheli M, Calevo MG et al (2017) Prenatal echocardiographic assessment of foramen ovale appearance in fetuses with D-transposition of the great arteries and impact on neonatal outcome. Fetal Diagn Ther 42(1):48–56
Słodki M, Axt-Fliedner R, Zych-Krekora K, Wolter A, Kawecki A, Enzensberger C et al (2018) New method to predict need for Rashkind procedure in fetuses with dextro-transposition of the great arteries. Ultrasound Obstet Gynecol 51(4):531–536
Wilson AD, Rao PS, Aeschlimann S (1990) Normal fetal foramen flap and transatrial Doppler velocity pattern. J Am Soc Echocardiogr 3(6):491–494
Brossard-Racine M, du Plessis A, Vezina G, Robertson R, Donofrio M, Tworetzky W et al (2016) Brain injury in neonates with complex congenital heart disease: what is the predictive value of mri in the fetal period? AJNR Am J Neuroradiol 37(7):1338–1346
Andropoulos DB, Hunter JV, Nelson DP, Stayer SA, Stark AR, McKenzie ED et al (2010) Brain immaturity is associated with brain injury before and after neonatal cardiac surgery with high-flow bypass and cerebral oxygenation monitoring. J Thorac Cardiovasc Surg 139(3):543–556
Beca J, Gunn JK, Coleman L, Hope A, Reed PW, Hunt RW et al (2013) New white matter brain injury after infant heart surgery is associated with diagnostic group and the use of circulatory arrest. Circulation 127(9):971–979
Block AJ, McQuillen PS, Chau V, Glass H, Poskitt KJ, Barkovich AJ et al (2010) Clinically silent preoperative brain injuries do not worsen with surgery in neonates with congenital heart disease. J Thorac Cardiovasc Surg 140(3):550–557
Dimitropoulos A, McQuillen PS, Sethi V, Moosa A, Chau V, Xu D et al (2013) Brain injury and development in newborns with critical congenital heart disease. Neurology 81(3):241–248
Mukherjee D, Lindsay M, Zhang Y, Lardaro T, Osen H, Chang DC et al (2010) Analysis of 8681 neonates with transposition of the great arteries: outcomes with and without Rashkind balloon atrial septostomy. Cardiol Young 20(4):373–380
Donofrio MT, Bremer YA, Moskowitz WB (2004) Diagnosis and management of restricted or closed foramen ovale in fetuses with congenital heart disease. Am J Cardiol 94(10):1348–1351
Rudolph AM (2007) Aortopulmonary transposition in the fetus: speculation on pathophysiology and therapy. Pediatr Res 61(3):375–380
Funding
This research did not receive any specific grant from funding agencies in the public, commercial, or not-for-profit sectors.
Author information
Authors and Affiliations
Contributions
AT: study design, LP: coordinated study, MM, TA: major contributors in writing the manuscript; MM, TA, AT: analyzed and interpreted patient data. All authors read and approved the final manuscript. All authors contributed to the design, data analysis and critically read the final manuscript.
Corresponding author
Ethics declarations
Conflict of interest
The authors declare that they have no conflict of interest.
Ethical Approval
The study was approved by the Institution Review Board.
Additional information
Publisher's Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Supplementary Information
Below is the link to the electronic supplementary material.
Supplementary file1 (AVI 80104 kb)
Supplementary file2 (AVI 28453 kb)
Supplementary file3 (AVI 33528 kb)
Supplementary file4 (AVI 89215 kb)
Rights and permissions
About this article
Cite this article
Masci, M., Pasquini, L., Alsaied, T. et al. Reliability of Fetal Echocardiography in Predicting Postnatal Critical Hypoxia in Patients with Transposition of Great Arteries and Intact Ventricular Septum. Pediatr Cardiol 42, 1575–1584 (2021). https://doi.org/10.1007/s00246-021-02642-w
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00246-021-02642-w