Normal Reference Ranges for Pulmonary Artery Diameters in Preterm Infants

  • Lulu Abushaban
  • Mariappa Thinakar Vel
  • Jebaraj Rathinasamy
  • Prem N. Sharma
Original Article
  • 138 Downloads

Abstract

To establish normal reference ranges and Z-scores for pulmonary artery diameters in preterm infants and their correlation with body surface area, body weight, and chronological age. In a prospective study, 268 preterm infants, who fulfilled the inclusion criteria were examined. Echocardiograms were performed to measure the main pulmonary artery, right pulmonary artery, and left pulmonary artery diameters on day(s) 0 to −6 of life and at weekly intervals until they reached 36 weeks of age. Body surface area was divided into thirteen groups from 0.07 to 0.19 m2. The mean gestational age was 29.8 (±2.38 SD) weeks, ranging between 24 and 35, the mean body weight was 1479 (±413 SD) grams, ranging between 588 and 3380, and the mean body surface area was 0.13 m2, ranging between 0.07 and 0.19 m2. All the pulmonary artery diameters correlated well with both body weight and body surface area. Reference ranges, with mean ± SD, range, and Z-scores for aortic diameters according to body surface area were calculated. A significant gradual increase was observed in main and branch pulmonary artery diameters with increasing body surface area. Overall, a progressive and significant increase for main and branch pulmonary artery diameters was observed during the first nine weeks of life. The main and branch pulmonary artery diameters were found to have significant correlation with body surface area. The study also provides reference data with Z-scores, which can be used as a normal reference tool for measuring the main pulmonary artery, right, and left pulmonary artery diameters of preterm infants against body surface area.

Keywords

Pulmonary artery diameters Body surface area Preterm infants babies Reference ranges Z-scores 

Notes

Acknowledgements

The authors would like to thank Dr.Niran Al Naqeeb and Dr.Majda Sabri, both neonatologists, for facilitating access to the preterm infants.

Funding

The study was funded by a grant from the Kuwait Foundation for the Advancement of Sciences (KFAS). (Grant Number: 2003-1302-05).

Compliance with Ethical Standards

Conflict of interest

The authors declares that they have no competing interest.

Ethical Standards

Ethical approval was obtained from the ethical committees of both the, Ministry of Health, Kuwait and the Faculty of Medicine of Kuwait University. The parents were informed that the infant would be enrolled in an observational study and not in any therapeutic trial.

Informed Consent

Prior written consent was obtained from the parents.

References

  1. 1.
    Elder I, Hertz CH (1954) Use of ultrasonic reflectoscope for the continuous recording of movements of heart walls. Kungl Fysiogr Sallsk Lund Forhandl 24:5Google Scholar
  2. 2.
    Solinger R, Elbl F, Minkas K (1973) Echocardiography in the normal neonate. Circulation 47:108–117CrossRefPubMedGoogle Scholar
  3. 3.
    Abushaban L, Vel MT, Rathinasamy J et al (2014) Normal reference ranges for left ventricular dimensions in preterm infants. Ann Pediatr Cardiol 7:180–186CrossRefPubMedPubMedCentralGoogle Scholar
  4. 4.
    Abushaban L, Vel MT, Rathinasamy J et al (2015) Normal reference ranges for cardiac valve annulus in preterm infants. Pediatr Cardiol 37(1):112–119CrossRefPubMedGoogle Scholar
  5. 5.
    Henry WL, Demaria A, Gramiak et al (1980) Report of the American society of Echocardiography Committee on nomenclature and standards in two-dimensional echocardiography. Circulation 62:212–217CrossRefPubMedGoogle Scholar
  6. 6.
    Silverman N (1993) Quantitative methods to enhance morphological information using M-mode Doppler and cross sectional ultrasound. In: Silverman N (ed) Paediatric echocardiography, vol 1, 1st edn. Williams and Wilkins, London, pp 35–36Google Scholar
  7. 7.
    Wyman WL, Geva T, Girish SS et al (2006) Guidelines and standards for performance of a pediatric echocardiogram: a report from the Task Force of the Pediatric Council of the American Society of Echocardiography. J Am Soc Echocardiogr 19:1413–1430CrossRefGoogle Scholar
  8. 8.
    Snider AR, Enderlein MA, Teitel DF, Juster RP (1984) Two-dimensional echocardiographic determination of aortic and pulmonary artery sizes from infancy to adulthood in normal subjects. Am J Cardiol 53:218–224CrossRefPubMedGoogle Scholar
  9. 9.
    DuBois D, DuBois EF (1916) A formula to estimate the approximate surface area if height and weight be known. Arch Intern Med 17:863–871CrossRefGoogle Scholar
  10. 10.
    Dyar D. Z-scores and reference values for pediatric echocardiography. http://www.parameterz.com. Accessed April 2016
  11. 11.
    Blackstone EH, Weintraub RG et al (1999) Relationship of the dimension of cardiac structures to body size: an echocardiographic study in normal infants and children. Cardiol Young 9(4):402–410PubMedGoogle Scholar
  12. 12.
    Pettersen MD, Du W, Skeens ME, Humes RA (2008) Regression equations for calculation of z scores of cardiac structures in a large cohort of healthy infants, children, and adolescents: an echocardiographic study. J Am Soc Echocardiogr 21:922–934CrossRefPubMedGoogle Scholar
  13. 13.
    Mawad W, Drolet C, Dahdah N, Dallaire F (2013) A review and critique of the statistical methods used to generate reference values in pediatric echocardiography. J Am Soc Echocardiogr 26:29–37CrossRefPubMedGoogle Scholar
  14. 14.
    Colan SD (2013) The why and how of Z scores. J Am Soc Echocardiogr 26:38–40CrossRefPubMedGoogle Scholar
  15. 15.
    Lopez L (2012) Pediatric echocardiography quality improvement. J Am Soc Echocardiogr 25:22A–23APubMedGoogle Scholar
  16. 16.
    Sluysmans T, Colan SD (2005) Theoretical and empirical derivation of cardiovascular allometric relationships in children. J Appl Physiol 99:445–457CrossRefPubMedGoogle Scholar
  17. 17.
    Haycock GB, Schwartz GJ, Wisotsky DH (1978) Geometric method for measuring body surface area: a height-weight formula validated in infants, children, and adults. J Pediatr 93:62–66CrossRefPubMedGoogle Scholar
  18. 18.
    Musteller RD (1987) Simplified calculation of body surface area. N Engl J Med 317:1098Google Scholar
  19. 19.
    Dreyer G, Ray W (1912) Further experiments upon the blood volume of mammals and its relation to the surface area of the body. Philos Trans R Soc Lond 202:191–212CrossRefGoogle Scholar
  20. 20.
    Boyd E (1935) The growth of the surface area of the human body. Greenwood, WestportGoogle Scholar
  21. 21.
    Gehan EA, George SL (1970) Estimation of human body surface area from height and weight. Cancer Chemother Rep 54:225–235PubMedGoogle Scholar
  22. 22.
    Ahn Y, Garruto RM (2008) Estimations of body surface area in newborns. Acta Paediatr 97:366–370CrossRefPubMedGoogle Scholar
  23. 23.
    Lofland GK, McCrindle BW, Williams WG, Blackstone EH, Tchervenkov CI, Sittiwangkul R et al (2001) Congenital Heart Surgeons Society. Critical aortic stenosis in the neonate: a multi-institutional study of management, outcomes, and risk factors. J Thorac Cardiovasc Surg 121:10–27CrossRefPubMedGoogle Scholar
  24. 24.
    Manlhiot C, Millar K, Golding F, McCrindle BW (2010) Improved classification of coronary artery abnormalities based only on coronary artery Z-scores after Kawasaki disease. Pediatr Cardiol 31:242–249CrossRefPubMedGoogle Scholar
  25. 25.
    Tan TH, Heng JT, Wong KY (2001) Pulmonary artery diameters in preterm infants: normal ranges. Singap Med J 42(3):102–106Google Scholar
  26. 26.
    Toshiro I, Satomi Gengi, Satoshi Y et al (1995) Normal values for cardiac and great arterial dimensions in premature infants by crosssectional echocardiography. Cardiol Young 5:319–325CrossRefGoogle Scholar
  27. 27.
    de waal K, Kluckow M, Evans N (2013) Weight corrected percentiles for blood vessel diameters used in flow measurements in preterm infants. J Early Hum Dev 89(12):939–942CrossRefGoogle Scholar
  28. 28.
    McGoon C, Baird DK, Davis GD (1975) Surgical management of large bronchial collateral arteries with pulmonary stenosis or atresia. Circulation 52:109–118CrossRefPubMedGoogle Scholar
  29. 29.
    Nakata S, Imai Y, Takanashi Y et al (1984) A new method for the quantitative standardization of cross-sectional areas of the pulmonary arteries in congenital heart disease with decreased pulmonary blood flow. J Thorac Cardiovasc Surg 88(4):610–619PubMedGoogle Scholar
  30. 30.
    Trowitzsch E, Berger T, Stute M (1991) The diameter of the large arteries in the first 3 years of life: an echocardiographic study. Monatsschr Kinderheikd 139:355–359Google Scholar
  31. 31.
    Cantinotti M, Scalese M, Murzi B et al (2014) Echocardiographic nomograms for ventricular, valvular and arterial dimensions in Caucasian children with a special focus on neonates, infants and toddlers. J Am Soc Echocardiogr 27:179–191CrossRefPubMedGoogle Scholar
  32. 32.
    Cantinotti M, Scalese M, Murzi B et al (2012) Limitations of current Echocardiographic nomograms for left ventricular, valvular and arterial dimensions in children: a critical review. J Am Soc Echocardiogr 25:142–152CrossRefPubMedGoogle Scholar

Copyright information

© Springer Science+Business Media, LLC 2017

Authors and Affiliations

  • Lulu Abushaban
    • 1
    • 2
  • Mariappa Thinakar Vel
    • 3
  • Jebaraj Rathinasamy
    • 3
  • Prem N. Sharma
    • 4
  1. 1.Chest Diseases HospitalKuwaitKuwait
  2. 2.Kuwait UniversityKuwaitKuwait
  3. 3.Chest Diseases Hospital, Ministry of HealthKuwaitKuwait
  4. 4.Faculty of Medicine, Health Sciences CenterKuwait UniversityKuwaitKuwait

Personalised recommendations