Reversal of Fenestration Flow During Ventricular Systole in Fontan Patients in Junctional or Ventricular Paced Rhythm

  • Published:
Pediatric Cardiology Aims and scope Submit manuscript

Abstract

Sinus node dysfunction is relatively common in patients with Fontan palliation for single ventricle congenital heart disease, and such patients often are in junctional rhythm or may have pacemaker systems for bradycardia. Because the physiologic determinants of left atrial pressure play a major role in determining pulmonary blood flow and therefore cardiac output in Fontan patients, the loss of atrioventricular (AV) synchrony in junctional rhythm or demand ventricular pacing in these patients might be expected to influence cardiac output. We report two cases of Fontan patients with the absence of AV synchrony that resulted in reversal of flow through the Fontan fenestration during ventricular systole. In both cases, restoration of AV synchrony by atrial pacing resulted in the elimination of retrograde fenestration flow, increased cardiac output, and improved clinical status.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2

Similar content being viewed by others

References

  1. Cohen MI, Rliodes LA, Wernovsky G, et al. (2001) Atrial pacing: an alternative treatment for protein-losing enteropathy after the Fontan operation. J Thorac Cardiovasc Surg 121:582–583

    PubMed  CAS  Google Scholar 

  2. Cohen MI, Wernovsky G, Vetter VL, et al. (1998) Sinus node function after a systemically staged Fontan procedure. Circulation 98(Suppl 2):352–359

    Google Scholar 

  3. Fishberger SB, Wernovsky G, Gentles TL, et al. (1996) Long-term outcome in patients with pacemakers following the Fontan operation. Am J Cardiol 77:887–889

    Article  PubMed  CAS  Google Scholar 

  4. Manning PB, Mayer JE Jr, Wernovski G, Fishberger SB, Walsh EP (1996) Staged operation to Fontan increases the incidence of sinoatrial node dysfunction. J Thorac Cardiovasc Surg 111:833–840

    PubMed  CAS  Google Scholar 

  5. Rychik J, Fogel MA, Donofrio MT, et al. (1997) Comparison of patterns of pulmonary venous blood flow in the functional single ventricle heart after operative aortopulmonary shunt versus superior cavopulmonary shunt. Am J Cardiol 80:922–926

    Article  PubMed  CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to D. Schneider.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Hasselman, T., Schneider, D., Madan, N. et al. Reversal of Fenestration Flow During Ventricular Systole in Fontan Patients in Junctional or Ventricular Paced Rhythm. Pediatr Cardiol 26, 638–641 (2005). https://doi.org/10.1007/s00246-005-0879-6

Download citation

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00246-005-0879-6

Keywords

Navigation