Abstract
We evaluated the usefulness of patent ductus arteriosus (PDA) occlusion using a new catheter that combines good angiographic properties, easy manipulation across the duct, documentation of aortic and pulmonary artery pressure, and coil delivery for percutaneous transaortic ductal occlusion. Thirty patients (13 females and 17 males) who met the clinical and echocardiographic criteria for the percutaneous closure of PDA were catheterized. The patients selected for this study had a small to moderate PDA with a conal or tubular shape, adequate aortic ampula, and normal or mildly elevated pulmonary artery pressure. The median age was 4.8 years (range, 10 months–20 years). Patients were catheterized by the transaortic approach using the new angiographic and coil delivery catheter specially designed for this procedure. A PDA was closed in every case. A single DuctOcclud pfm coil was delivered in 28 patients, and 2 patients had NitOcclud pfm coils for ductal occlusion. The screening time was measured and found to be 50% less than the measured screening time using other catheters in our laboratory. Only one catheter and one guidewire were used per procedure, with no need for exchange wires or the establishment of an arteriovenous loop. The procedure time was also reduced by 50%. A minimal residual shunt, demonstrated by color-flow Doppler mapping, was present in 2 patients. The new combined angiographic and coil delivery catheter is most suitable for transaortic PDA coil occlusion, significantly decreasing the procedure and screening time.
Similar content being viewed by others
References
RE Gross JP Hubbard (1939) ArticleTitleDuctus arteriosus: surgical ligation of a patent ductus arteriosus. J Am Med Assoc 8 729
JC Munro (1907) ArticleTitleLigation of the ductus arteriosus. Ann Surg 46 335
T Podnar P Gavora J Masura (2000) ArticleTitlePercutaneous closure of patent ductus arteriosus: complementary use of detachable Cook patent ductus arteriosus coils and Amplatzer duct occluders. Eur J Pediatr 159 293–296 Occurrence Handle10.1007/s004310050073 Occurrence Handle1:STN:280:DC%2BD3c3kvVOquw%3D%3D Occurrence Handle10789937
T Podnar J Masura (1997) ArticleTitlePercutaneous closure of patent ductus arteriosus using a special screwing detachable coils. Cathet Cardiovasc Diagn 41 386–391 Occurrence Handle10.1002/(SICI)1097-0304(199708)41:4<386::AID-CCD7>3.0.CO;2-1 Occurrence Handle1:STN:280:ByiH3czhtFQ%3D Occurrence Handle9258479
W Portsmann L Wierny H Warnke G Gerstberger PA Romaniuk (1971) ArticleTitleCatheter closure of patent ductus arteriosus. 62 cases treated without thoracotomy. Radiol Clin North Am 9 203–218
WJ Rashkind (1983) ArticleTitleTranscatheter treatment of congenital heart disease. Circulation 67 11–16 Occurrence Handle6183020
WJ Rashkind CC Cuaso (1979) ArticleTitleTranscatheter closure of patent ductus arteriosus. Successful use in a 3.5 kg infant. Pediatr Cardiol 1 3–7
A Rothman VW Lucas MS Sklanski MW Cocalis IA Kashani (1997) ArticleTitlePercutaneous coil occlusion of patent ductus arteriosus. J Pediatr 130 447–454 Occurrence Handle1:STN:280:ByiB3MjktVY%3D Occurrence Handle9063423
K Sato M Fujino T Kozuka et al. (1975) ArticleTitleTransfemoral plug closure of patent ductus arteriosus. Experiences in 61 consecutive cases treated without thoracotomy. Circulation 51 337–341 Occurrence Handle1:STN:280:CSqD1M3jsVQ%3D Occurrence Handle1112014
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Lorber, A., Gazit, A., Khoury, A. et al. Percutaneous Transaortic Occlusion of Patent Ductus Arteriosus Using a New Versatile Angiographic and Delivery Catheter . Pediatr Cardiol 24, 482–483 (2003). https://doi.org/10.1007/s00246-002-0235-z
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00246-002-0235-z