Abstract
The aim of this study was to assess the use of aldehyde indicator pads for detection of glutaraldehyde and alkaline glutaraldehyde permeation through chemical protective gloves under simulated in-use conditions. The quantitative analysis of glutaraldehyde permeation through a glove material was determined for Metricide, Wavicide, and 50% glutaraldehyde following a solvent-desorption process and gas chromatographic analysis. All glutaraldehyde solutions exhibited >99% adsorption (including both the glutaraldehyde oligomers of the reaction product and the excess glutaraldehyde) on the pads over the spiking range 0.05–5.0 μL. Breakthrough times for protective gloves were determined using the Thermo-Hand test method, and found to range from 76 to 150, from 170 to 230, and from 232 to 300 min for Metricide, Wavicide, and 50% glutaraldehyde, respectively. Glutaraldehyde recovery was calculated and ranged from 61 to 80% for all glutaraldehyde solutions. The mass of glutaraldehyde in these solutions at the time of breakthrough detection ranged from 17 to 18, from 18 to 19, and from 19 to 20 μg/cm2 for Wavicide, 50% glutaraldehyde solution, and Metricide, respectively. Aldehyde indicator pads and the Thermo-Hand test method together should find utility in detecting, collecting, and quantitatively analyzing glutaraldehyde permeation samples through chemical protective gloves under simulated in-use conditions.
Similar content being viewed by others
References
Boeniger M, Klingner T (2002) In-use testing and interpretation of chemical-resistant glove performance. Appl Occup Environ Hyg 17:368–378. doi:10.1080/10473220252864978
Ehntholt D, Bodek I, Valentine JR (1989) The effects of solvent type and concentration on the permeation of pesticide formulations through chemical protective glove materials. In: Perkins JL, Stull JO (eds) Chemical protective clothing performance in chemical emergency response, ASTM STP 1037. American Society of Testing and Materials, Philadelphia, PA
Fisher AA (1981) Reaction of glutaraldehyde with particular reference to radiologists and X-ray technicians. Cutis 28:113–122
Goncalo S, Brandao M, Pecegueiro M, Moreno A, Sousa I (1984) Occupational contact dermatitis to glutaraldehyde. Contact Dermat 10:183–184. doi:10.1111/j.1600-0536.1984.tb00033.x
Hansen KS (1983) Glutaraldehyde occupational dermatitis. Contact Dermat 9:81–82. doi:10.1111/j.1600-0536.1983.tb04639.x
Hathaway GJ, Proctor NH, Hughes JP (1996) Proctor and Hughes’ chemical hazards of the workplace, 4th edn. John Wiley and Sons, New York
Klingner T (1999) Device and method for detecting chemical breakthrough of protective clothing. US Patent 5,976,881, 2 Nov 1999
OSHA (1994) U.S. Occupational Safety and Health Administration: personal protective equipment for general industry, final rule. CFR 59, No. 66, pp. 16334–16364
Rowell FJ, Fletcher A, Pachham C (1997) Recovery of some common solvents from an adhesive commercial skin adsorption pad by thermal desorption-gas chromatography. Analyst 122:793–796. doi:10.1039/a700917h
Vo E (2002) A new technique to determine organic and inorganic acid contamination. Analyst 127:178–182. doi:10.1039/b106282b
Vo E (2004) Application of colorimetric indicators and thermo-hand method to determine base permeation through chemical protective gloves. J Occup Environ Hyg 1:799–805. doi:10.1080/15459620490887048
Vo E, Berardinelli S (1999) Determination of alkylamine permeation through protective gloves using aliphatic amine pads. J Environ Monit 1:545–548. doi:10.1039/a906477j
Vo E, Berardinelli S, Hall R (1999) Recovery of some common solvents from protective clothing breakthrough indicator pads by microwave-solvent extraction and gas chromatography. Analyst 124:941–944. doi:10.1039/a809248f
Vo E, Berardinelli S, Hall R, Ayouby N (2000) A quantitative study of aromatic amine permeation through protective glove using amine adsorptive pads. Am Ind Hyg Assoc J 61:837–841. doi:10.1202/0002-8894(2000)061<0837:AQSOAA>2.0.CO;2
Vo E, Berardinelli S, Boeniger M (2001) The use of 3M porous polymer extraction discs in assessing protective clothing chemical permeation. J Appl Occup Environ Hyg 16:729–735. doi:10.1080/10473220152403655
Vo E, Murray D, Scott T, Attar A (2007) Development of a novel colorimetric indicator for detecting aldehydes. Talanta 73:87–94. doi:10.1016/j.talanta.2007.03.014
Zellers E, Sulewski R (1993) Modeling the temperature dependence of N-methylpyrrolidone permeation through butyl-and natural rubber gloves. Am Ind Hyg Assoc J 54:465–479. doi:10.1080/15298669391354991
Acknowledgments
This work was conducted as part of the National Occupational Research Agenda (NORA) Dermal Exposure Research Program. The authors express their sincere appreciation to Quynh-Giao Nguyen, Jennifer Nguyen Vo, and Elaine Nguyen Vo for their valuable support.
Author information
Authors and Affiliations
Corresponding author
Additional information
The findings and conclusions in this paper are those of the authors and do not necessarily represent the views of the National Institute for Occupational Safety and Health (NIOSH). Mention of company names or products does not constitute endorsement by the NIOSH.
Rights and permissions
About this article
Cite this article
Vo, E., Zhuang, Z. The Use of Aldehyde Indicators to Determine Glutaraldehyde and Alkaline Glutaraldehyde Contamination in Chemical Protective Gloves. Arch Environ Contam Toxicol 57, 185–192 (2009). https://doi.org/10.1007/s00244-009-9316-9
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00244-009-9316-9