Abstract
Background
Due to its unpredictable retention rate, using autologous fat alone for the enhancement of breast volume is often unsatisfactory. To overcome this limitation, fat transfer has been proposed as an immediate adjuvant procedure to aesthetic breast surgery, creating the concept of hybrid mammoplasty.
Fat transfer has already been shown to correct minor defects with good clinical outcome, but the amount of fat that can be safely transferred has not yet been identified. Our hypothesis is that contour improvement with small-volume fat transfer as a primary adjuvant treatment can lead to a better patient outcome.
Methods
A retrospective single-centre uncontrolled case series study was conducted on 70 patients who underwent hybrid mammoplasties for aesthetic purposes only. Primary and secondary cases were included and divided into corresponding groups. An ad-hoc outcome scale based on clinical parameters was created to standardise results; results were analysed after a follow-up period of at least 12 months.
Results
The overall results were reported as good in 48.7% of cases, moderate in 32.8%, and sufficient in 18.5%. Primary cases with small deformities showed a better outcome on our scale compared to revisional ones (57.4% good compared to 29%; p = 0.038). A transferred volume of fat up to 100 ml was associated with a higher retention rate (OR = 2.3; p = 0.032).
Conclusions
Small breast contour deformities or prosthesis coverage can be easily corrected with fat transfer. Based on our score system, this technique is indicated for volume enhancement up to 100 ml; beyond that the outcome quality decreases, and further corrections would be needed.
Level of evidence: Level IV, Therapeutic.
Similar content being viewed by others
Data availability
Not applicable.
References
Hoon SY, Cui CX, Cao J, Hong ZR (2020) Better clinical outcome for autologous fat transplant combined with silicone gel prosthesis for breast augmentation: evidence from meta-analysis. Asian J Surg 43(1):166–180
Bravo FG (2015) Parasternal infiltration composite breast augmentation. Plast Reconstr Surg 135(4):1010–1018
Auclair E, Blondeel P, Del Vecchio DA (2013) Composite breast augmentation: soft-tissue planning using implants and fat. Plast Reconstr Surg 132(3):558–568
Graf RM, Closs Ono MC, Pace D, Balbinot P, Pazio ALB, de Paula DR (2019) Breast auto-augmentation (mastopexy and lipofilling): an option for quitting breast implants. Aesthetic Plast Surg 43(5):1133–1141
Coleman SR, Saboeiro AP (2015) Primary breast augmentation with fat grafting. Clin Plast Surg 42(3):301–306
Krastev TK, Alshaikh GAH, Hommes J, Piatkowski A, van der Hulst RRWJ (2018) Efficacy of autologous fat transfer for the correction of contour deformities in the breast: a systematic review and meta-analysis. J Plast Reconstr Aesthet Surg 71(10):1392–1409
Del Vecchio DA, Bucky LP (2011) Breast augmentation using preexpansion and autologous fat transplantation: a clinical radiographic study. Plast Reconstr Surg 127(6):2441–2450
Kerfant N, Marchac A, Auclair E (2019) Fat grafting in composite breast augmentation with round implants: a new concept for breastreshaping. Aesthetic Plast Surg 43(2):550–551
Serra-Mestre JM, Fernandez Peñuela R, Foti V, D’Andrea F, Serra-Renom JM (2017) Breast cleavage remodeling with fat grafting: a safe way to optimize symmetry and to reduce intermammary distance. Plast Reconstr Surg 140(5):665e–672e
Tepper OM, Unger JG, Small KH, Feldman D, Kumar N, Choi M, Karp NS (2010) Mammometrics: the standardization of aesthetic and reconstructive breast surgery. Plast Reconstr Surg 125:393–400
Hall-Findlay EJ (2010) The three breast dimensions: analysis and effecting change. Plast Reconstr Surg 125:1632–1642
Mallucci P, Branford OA (2014) Population analysis of the perfect breast: a morphometric analysis. Plast Reconstr Surg 134:436–447
Mallucci P, Branford OA (2015) Shapes, proportions, and variations in breast aesthetic ideals: the definition of breast beauty, analysis, and surgical practice. Clin Plast Surg 42:451–464
Murillo WL (2004) Buttock augmentation: case studies of fat injection monitored by magnetic resonance imaging. Plast Reconstr Surg 114(6):1606–1614
C.rdenas-Camarena L, Arenas-Quintana R, Robles-Cervantes JA (2011) Buttocks fat grafting: 14 years of evolution and experience. Plast Reconstr Surg 128(2):545–555
Auclair E, Anavekar N (2015) Combined use of implant and fat grafting for breast augmentation. Clin Plast Surg 42(3):307–314
Yoshimura K, Sato K, Aoi N, Kurita M, Hirohi T, Harii K (2008) Cell-assisted lipotransfer for cosmetic breast augmentation: supportive use of adipose-derived stem/stromal cells. Aesthetic Plast Surg 32(1):48–55
Munhoz AM, de Azevedo Marques Neto A, Maximiliano J (2021) Subfascial ergonomic axillary hybrid (SEAH) breast augmentation: a surgical approach combining the advantages of incision, pocket, silicone gel, and fat grafting in primary and revision breast augmentation surgery. Aesthet Surg J 41(6):NP364–NP384
Munhoz AM, de Azevedo Marques Neto A, Maximiliano J (2022) Optimizing surgical outcomes with small-volume silicone implants associated with autogenous fat grafting in primary and revision breast augmentationsurgery: soft weight hybrid (SWEH) concept. Aesthetic Plast Surg 46(3):1087–1103
Maximiliano J, Munhoz AM, Pedron M, de Oliveira ACP, Duarte DW, Neto R, Portinho CP, Collares MVM (2020) Hybrid breast augmentation: a reliable formula for preoperative assessment of fat graft volume based on implant volume and projection. Aesthet Surg J 40(8):NP438–NP452
Largo RD, Tchang LA, Mele V, Scherberich A, Harder Y, Wettstein R, Schaefer DJ (2014) Efficacy, safety and complications of autologous fat grafting to healthy breast tissue: a systematic review. J Plast Reconstr Aesthet Surg 67:437–448
Guo X, Jin X (2019) Management of fat necrosis after autologous fat transplantation for breast augmentation. Plast Reconstr Surg 144(4):700e–701e
Funding
The authors declare that no funds, grants, or other support were received during the preparation of this manuscript.
Author information
Authors and Affiliations
Contributions
All authors contributed to the study conception and design. Material preparation, data collection, and analysis were performed by Zoccali, Pompei, and Farhadi. The first draft of the manuscript was written by Zoccali, and all authors commented on previous versions of the manuscript. All authors read and approved the final manuscript.
Corresponding author
Ethics declarations
Ethical Approval
Local Ethical Committee approved the study protocol. All procedures performed in studies involving human participants were in accordance with the ethical standards of the institutional and/or national research committee and with the 1964 Helsinki Declaration and its later amendments or comparable ethical standards.
Consent to participate
Informed consent was obtained from all individual participants included in the study.
Conflict of interest
Giovanni Zoccali, Barbara Pompei, and Jian Farhadi declare no competing interests.
Additional information
Publisher's note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
Springer Nature or its licensor (e.g. a society or other partner) holds exclusive rights to this article under a publishing agreement with the author(s) or other rightsholder(s); author self-archiving of the accepted manuscript version of this article is solely governed by the terms of such publishing agreement and applicable law.
About this article
Cite this article
Zoccali, G., Pompei, B. & Farhadi, J. Primary—but not secondary—adjuvant fat transfer is associated with good patient satisfaction in mammoplasty: a single centre retrospective case series. Eur J Plast Surg 46, 351–360 (2023). https://doi.org/10.1007/s00238-022-02011-7
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00238-022-02011-7