Skip to main content

Advertisement

Log in

The efficacy of Gore-Tex vs. hydroxyapatite and bone graft in reconstruction of orbital floor defects

  • Original Paper
  • Published:
European Journal of Plastic Surgery Aims and scope Submit manuscript

Abstract

Fractures of the orbital floor often need to be reconstructed with rigid materials that provide a stable orbital floor and reestablish the correct orbital volume. In addition to autologous bone grafts, many alloplastic materials are available such as hydroxyapatite and, recently, expanded polytetrafluoroethylene reinforced with fluorinated ethylene propylene also known as reinforced SAM Gore-Tex. This study compared the efficacy and biocompatibility of reinforced and nonreinforced SAM Gore-Tex to those of hydroxyapatite and autogenous bone graft for reconstructing the orbital floor. A defect measuring 1.5×1.0 cm was created in the left orbital floor in 24 short-hair cats while the right side served as the control. The cats were divided into four groups, the defect being reconstructed with an autogenous iliac crest corticocancellous bone graft (group A), hydroxyapatite (group B), nonreinforced Gore-Tex (group C), or reinforced Gore-Tex (group D). Computed tomography was performed postoperatively at 1 and 8 weeks, and at the conclusion of the study specimens from the left orbit were harvested to evaluate the histological biocompatibility of each material. Reinforced SAM Gore-Tex possessed excellent physical properties. It was malleable yet firm enough and therefore easily contoured during repair of the defect while strong enough to support the orbital contents. It could even be sutured to the orbital rim or a fixating plate to ensure further stabilization, if necessary. Additionally, the material demonstrated exemplary biocompatibility as it initiated a minimal inflammatory response. As healing progressed, a growth of host tissue into the material was noted in all histological specimens, thereby augmenting the stability of the implant and reducing the incidence of extrusion.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1.
Fig. 2.
Fig. 3.

Similar content being viewed by others

References

  1. Bagatin M (1987) Reconstruction of orbital defects with autogenous bone from mandibular symphysis. J Craniomaxillofac Surg 15:103

    CAS  PubMed  Google Scholar 

  2. Browing C, Walker R (1965) The use of alloplastics in 45 cases of orbital floor reconstruction. Am J Ophthalmol 60:684

    PubMed  Google Scholar 

  3. Chen JM, Zingg M, Laedrach K, Raveh J (1992) Early surgical intervention for orbital floor fracture. J Oral Maxillofac Surg 50:935

    CAS  PubMed  Google Scholar 

  4. Crikelair GF, Rein JM, Potter GD (1972) A critical look at blowout fractures. Plast Reconstr Surg 49:374

    CAS  PubMed  Google Scholar 

  5. Graham L, Bergan J (1982) Biologic and synthetic vascular prostheses. New York, Grune & Stratton

  6. Guerra MFM, Perez JS, Rodriguez-Campo FJ, Gias LN (2000) Reconstruction of orbital fractures with dehydrated human dura matter. J Oral Maxillofac Surg 58:1361

    Article  CAS  PubMed  Google Scholar 

  7. Hanson LJ, Donovan MG, Hellstien JW, Dicrson NC (1994) Experimental evaluation of expanded polytetrafluoroethylene for reconstruction of orbital floor defects. J Oral Maxillofac Surg 52:1050

    CAS  PubMed  Google Scholar 

  8. Hes J, de Man K (1998) Use of blocks of hydroxyapatite for secondary reconstruction of the orbital floor. Int J Oral Maxillofac Surg 19:275

    Google Scholar 

  9. Jordan DR, St. Onge P, Anderson RL, et al (1992) Complications associated with alloplastic implants used in orbital fracture repair. Ophthalmology 99:1600

    CAS  PubMed  Google Scholar 

  10. Karesh JW (1987) Polytetrafluoroethylene as a graft material in ophthalmic plastic and reconstructive surgery. Ophthal Plast Reconstr Surg 3:179

    CAS  PubMed  Google Scholar 

  11. Kinnuen I, Aitasalo K, Pollonen M, Vorpula M (2000) Reconstruction of orbital floor fracture using bioactive glass. J Craniomaxillofac Surg 28:229

    PubMed  Google Scholar 

  12. Kirkeguar J, Greison O, Hojslet P (1986) Orbital floor fractures: Early repair and results. Clin Otolaryngol 11:69

    PubMed  Google Scholar 

  13. Lee HH, Alcarar N, Reino A, Lawson W (1998) Reconstruction of orbital floor fractures with maxillary bone. Arch Otolaryngol Head Neck Surg 124:56

    CAS  PubMed  Google Scholar 

  14. Lizuka T, Mikkonen P, Paukkua P, et al (1991) Reconstruction of orbital floor with Polydioxamone plate. Int J Oral Maxillofac Surg 20:83

    PubMed  Google Scholar 

  15. Loftfield K, Jordan DR, Fowler J, Anderson RL (1987) Orbital cyst formation associated with Gelfilm use. Ophthal Plast Reconstr Surg 3:187

    CAS  PubMed  Google Scholar 

  16. Ma L, Wong S, Wu C, et al (1987) Orbital reconstruction with Proplast. Ophthal Plast Reconstr Surg 3:151

    CAS  PubMed  Google Scholar 

  17. Mathog RH (1991) Management of orbital blow out fractures. Otolaryngol Clin North Am 24:79

    CAS  PubMed  Google Scholar 

  18. Mauriello J, McShane R, Voglino J (1990) Use of Vicryl (Polyglactin-910) mesh implant for correcting enophthalmos and hypo-ophthalmos: a study of 16 patients. Ophthalmol Plast Reconstr Surg 6:247

    Google Scholar 

  19. Meritt K, Shafer JW, Brown SA (1979) Implant site infection rates with porous and dense materials. J Biomed Mater Res 13:101

    CAS  PubMed  Google Scholar 

  20. Meyers A (1991) Recent advances in the management of orbital trauma: reconstruction and complications. Arch Otolaryngol Head Neck Surg 117:593

    PubMed  Google Scholar 

  21. Morain W, Colby E, Stuffer M, et al (1987) Reconstruction of orbital wall fenestration with Polyglactin 910 film. Plast Reconstr Surg 80:769

    CAS  PubMed  Google Scholar 

  22. Nguyen P, Sullivan P (1992) Advances in the management of Orbital fractures. Clin Plast Surg 19:87

    CAS  PubMed  Google Scholar 

  23. Rosen HM (1991) The response of porous hydroxyapatite to contiguous tissue infection. Plast Reconstr Surg 88:1076

    CAS  PubMed  Google Scholar 

  24. Roy DM, Linnenhan SK (1974) Hydroxyapatite formed from coral skeletal carbonate by hydrothermal exchange. Nature 247:220

    CAS  PubMed  Google Scholar 

  25. Rubin PAD, Bilyk JR, Shore JW (1994) Orbital reconstruction using polyethylene sheets. Ophthalmology 101:1697

    Google Scholar 

  26. Scapini D, Mathog R (1987) Repair of orbital floor fractures with Marlex mesh. Laryngoscope 99:697

    Google Scholar 

  27. Sewall S, Pernoud F, Pernoud M (1986) Late reaction to silicone following reconstruction of an orbital floor fracture. J Oral Maxillofac Surg 14:821

    Google Scholar 

  28. Smith B, Putterman AM (1970) Fixation of orbital floor implants. Description of a simple technique. Arch Ophthalmol 83:598

    CAS  PubMed  Google Scholar 

  29. Thaller S, Zarem H, Kawamoto H (1987) Surgical correction of late sequelae from facial bone fractures. Am J Surg 154:149

    CAS  PubMed  Google Scholar 

  30. Tse DT (1986) Cyanoacrylate tissue adhesive in securing orbital implants. Ophthalmic Surg 17:577

    CAS  PubMed  Google Scholar 

  31. Visscher J de, Van der Wal K (1988) Medial orbital wall fracture with enophthalmos. J Craniomaxillofac Surg 16:55

    PubMed  Google Scholar 

  32. Waite P, Clanton J (1988) Orbital floor reconstruction with lyophilized dura. J Oral Maxillofac Surg 46:727

    CAS  PubMed  Google Scholar 

  33. White RA, Weber JN, White EW (1972) Replamineform: a new process for preparing porous ceramic, metal, and polymer prosthetic materials. Science 176:922

    CAS  PubMed  Google Scholar 

  34. Wilkins RB, Havins WE (1982) Current treatment of blowout fractures. Am Acad Ophthal 89:464

    CAS  Google Scholar 

  35. Yaremchuk M (1992) Changing concepts in the management of secondary orbital deformities. Clin Plast Surg 19:113

    CAS  PubMed  Google Scholar 

Download references

Acknowledgements

This research was presented at the 12th Annual Meeting of the North American Skull Base Society, 3–6 March 2001 in Orlando, Fla., and the Annual Meeting of the Midwestern Association of Plastic Surgeons, 21–22 April 2001 in Chicago, Ill.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to I. T. Jackson.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Elmazar, H., Jackson, I.T., Degner, D. et al. The efficacy of Gore-Tex vs. hydroxyapatite and bone graft in reconstruction of orbital floor defects. Eur J Plast Surg 25, 362–368 (2003). https://doi.org/10.1007/s00238-002-0448-7

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00238-002-0448-7

Keywords

Navigation