Abstract
Fractures of the orbital floor often need to be reconstructed with rigid materials that provide a stable orbital floor and reestablish the correct orbital volume. In addition to autologous bone grafts, many alloplastic materials are available such as hydroxyapatite and, recently, expanded polytetrafluoroethylene reinforced with fluorinated ethylene propylene also known as reinforced SAM Gore-Tex. This study compared the efficacy and biocompatibility of reinforced and nonreinforced SAM Gore-Tex to those of hydroxyapatite and autogenous bone graft for reconstructing the orbital floor. A defect measuring 1.5×1.0 cm was created in the left orbital floor in 24 short-hair cats while the right side served as the control. The cats were divided into four groups, the defect being reconstructed with an autogenous iliac crest corticocancellous bone graft (group A), hydroxyapatite (group B), nonreinforced Gore-Tex (group C), or reinforced Gore-Tex (group D). Computed tomography was performed postoperatively at 1 and 8 weeks, and at the conclusion of the study specimens from the left orbit were harvested to evaluate the histological biocompatibility of each material. Reinforced SAM Gore-Tex possessed excellent physical properties. It was malleable yet firm enough and therefore easily contoured during repair of the defect while strong enough to support the orbital contents. It could even be sutured to the orbital rim or a fixating plate to ensure further stabilization, if necessary. Additionally, the material demonstrated exemplary biocompatibility as it initiated a minimal inflammatory response. As healing progressed, a growth of host tissue into the material was noted in all histological specimens, thereby augmenting the stability of the implant and reducing the incidence of extrusion.
Similar content being viewed by others
References
Bagatin M (1987) Reconstruction of orbital defects with autogenous bone from mandibular symphysis. J Craniomaxillofac Surg 15:103
Browing C, Walker R (1965) The use of alloplastics in 45 cases of orbital floor reconstruction. Am J Ophthalmol 60:684
Chen JM, Zingg M, Laedrach K, Raveh J (1992) Early surgical intervention for orbital floor fracture. J Oral Maxillofac Surg 50:935
Crikelair GF, Rein JM, Potter GD (1972) A critical look at blowout fractures. Plast Reconstr Surg 49:374
Graham L, Bergan J (1982) Biologic and synthetic vascular prostheses. New York, Grune & Stratton
Guerra MFM, Perez JS, Rodriguez-Campo FJ, Gias LN (2000) Reconstruction of orbital fractures with dehydrated human dura matter. J Oral Maxillofac Surg 58:1361
Hanson LJ, Donovan MG, Hellstien JW, Dicrson NC (1994) Experimental evaluation of expanded polytetrafluoroethylene for reconstruction of orbital floor defects. J Oral Maxillofac Surg 52:1050
Hes J, de Man K (1998) Use of blocks of hydroxyapatite for secondary reconstruction of the orbital floor. Int J Oral Maxillofac Surg 19:275
Jordan DR, St. Onge P, Anderson RL, et al (1992) Complications associated with alloplastic implants used in orbital fracture repair. Ophthalmology 99:1600
Karesh JW (1987) Polytetrafluoroethylene as a graft material in ophthalmic plastic and reconstructive surgery. Ophthal Plast Reconstr Surg 3:179
Kinnuen I, Aitasalo K, Pollonen M, Vorpula M (2000) Reconstruction of orbital floor fracture using bioactive glass. J Craniomaxillofac Surg 28:229
Kirkeguar J, Greison O, Hojslet P (1986) Orbital floor fractures: Early repair and results. Clin Otolaryngol 11:69
Lee HH, Alcarar N, Reino A, Lawson W (1998) Reconstruction of orbital floor fractures with maxillary bone. Arch Otolaryngol Head Neck Surg 124:56
Lizuka T, Mikkonen P, Paukkua P, et al (1991) Reconstruction of orbital floor with Polydioxamone plate. Int J Oral Maxillofac Surg 20:83
Loftfield K, Jordan DR, Fowler J, Anderson RL (1987) Orbital cyst formation associated with Gelfilm use. Ophthal Plast Reconstr Surg 3:187
Ma L, Wong S, Wu C, et al (1987) Orbital reconstruction with Proplast. Ophthal Plast Reconstr Surg 3:151
Mathog RH (1991) Management of orbital blow out fractures. Otolaryngol Clin North Am 24:79
Mauriello J, McShane R, Voglino J (1990) Use of Vicryl (Polyglactin-910) mesh implant for correcting enophthalmos and hypo-ophthalmos: a study of 16 patients. Ophthalmol Plast Reconstr Surg 6:247
Meritt K, Shafer JW, Brown SA (1979) Implant site infection rates with porous and dense materials. J Biomed Mater Res 13:101
Meyers A (1991) Recent advances in the management of orbital trauma: reconstruction and complications. Arch Otolaryngol Head Neck Surg 117:593
Morain W, Colby E, Stuffer M, et al (1987) Reconstruction of orbital wall fenestration with Polyglactin 910 film. Plast Reconstr Surg 80:769
Nguyen P, Sullivan P (1992) Advances in the management of Orbital fractures. Clin Plast Surg 19:87
Rosen HM (1991) The response of porous hydroxyapatite to contiguous tissue infection. Plast Reconstr Surg 88:1076
Roy DM, Linnenhan SK (1974) Hydroxyapatite formed from coral skeletal carbonate by hydrothermal exchange. Nature 247:220
Rubin PAD, Bilyk JR, Shore JW (1994) Orbital reconstruction using polyethylene sheets. Ophthalmology 101:1697
Scapini D, Mathog R (1987) Repair of orbital floor fractures with Marlex mesh. Laryngoscope 99:697
Sewall S, Pernoud F, Pernoud M (1986) Late reaction to silicone following reconstruction of an orbital floor fracture. J Oral Maxillofac Surg 14:821
Smith B, Putterman AM (1970) Fixation of orbital floor implants. Description of a simple technique. Arch Ophthalmol 83:598
Thaller S, Zarem H, Kawamoto H (1987) Surgical correction of late sequelae from facial bone fractures. Am J Surg 154:149
Tse DT (1986) Cyanoacrylate tissue adhesive in securing orbital implants. Ophthalmic Surg 17:577
Visscher J de, Van der Wal K (1988) Medial orbital wall fracture with enophthalmos. J Craniomaxillofac Surg 16:55
Waite P, Clanton J (1988) Orbital floor reconstruction with lyophilized dura. J Oral Maxillofac Surg 46:727
White RA, Weber JN, White EW (1972) Replamineform: a new process for preparing porous ceramic, metal, and polymer prosthetic materials. Science 176:922
Wilkins RB, Havins WE (1982) Current treatment of blowout fractures. Am Acad Ophthal 89:464
Yaremchuk M (1992) Changing concepts in the management of secondary orbital deformities. Clin Plast Surg 19:113
Acknowledgements
This research was presented at the 12th Annual Meeting of the North American Skull Base Society, 3–6 March 2001 in Orlando, Fla., and the Annual Meeting of the Midwestern Association of Plastic Surgeons, 21–22 April 2001 in Chicago, Ill.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Elmazar, H., Jackson, I.T., Degner, D. et al. The efficacy of Gore-Tex vs. hydroxyapatite and bone graft in reconstruction of orbital floor defects. Eur J Plast Surg 25, 362–368 (2003). https://doi.org/10.1007/s00238-002-0448-7
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00238-002-0448-7