Skip to main content
Log in

Combination of temporary bridging device (Comaneci) and permanent stenting in the treatment of unruptured wide neck bifurcation aneurysms

  • Short Report
  • Published:
Neuroradiology Aims and scope Submit manuscript

Abstract

The double stent-assisted techniques for the treatment of wide neck bifurcation aneurysms (WNBAs) may be more complicating than single stent-assisted or balloon-assisted coiling. The Comaneci device (Rapid Medical, Yokneam, Israel) is a new temporary bridging device developed for covering the aneurysm neck during coiling. This new design enabled us to treat unruptured WNBAs with the use of single stent-assisted coiling instead of double stent in eight patients. At the 1-year angiographic follow-up, there was no filling in any aneurysm. There was no mortality or morbidity cases related to the procedure. In this study, we are reporting our experience of using single stent-assisted coiling combined with a Comaneci device in the treatment of unruptured WNBAs.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3

Similar content being viewed by others

References

  1. Bhogal P, Udani S, Cognard C et al (2018) Endosaccular flow disruption: where are we now? J Neurointerv Surg 11:1024–1025. https://doi.org/10.1136/neurintsurg-2018-014623

    Article  Google Scholar 

  2. Oushy S, Rinaldo L, Brinjikji W et al (2020) Recent advances in stent-assisted coiling of cerebral aneurysms. Expert Rev Med Devices 17:519–532. https://doi.org/10.1080/17434440.2020.1778463.

    Article  CAS  PubMed  Google Scholar 

  3. Samaniego EA, Mendez AA, Nguyen TN et al (2018) LVIS Jr Device for Y-stent-assisted coil embolization of wide-neck intracranial aneurysms: a multicenter experience. Interv Neurol 7:271–283. https://doi.org/10.1159/000487545.

    Article  PubMed  PubMed Central  Google Scholar 

  4. Ciccio G, Robert T, Smajda S et al (2019) Double-stent assisted coiling of intracranial aneurysms in Y and X configurations with Neuroform ATLAS stent: immediate and mid-term angiographic and clinical follow-up. J Neurointerv Surg 11:1239–1242. https://doi.org/10.1136/neurintsurg-2019-015175.

    Article  PubMed  Google Scholar 

  5. Fischer S, Weber A, Carolus A et al (2017) Coiling of wide-necked carotid artery aneurysms assisted by a temporary bridging device (Comaneci): preliminary experience. J Neurointerv Surg 9:1039–1097. https://doi.org/10.1136/neurintsurg-2016-012664.

    Article  CAS  PubMed  Google Scholar 

  6. Zhao KJ, Young PF, Huang QH et al (2012) Y-Configuration stent placement (crossing and kissing) for endovascular treatment of wide neck cerebral aneurysms located at 4 different bifurcation sites. Am J Neuroradiol 33:1310–1316. https://doi.org/10.3174/ajnr.A2961.

    Article  PubMed  Google Scholar 

  7. Islak C, Kizilkilic O, Kocak B et al (2014) Use of buddy wire to facilitate Y-configured stent placement in middle cerebral artery bifurcation aneurysms with daughter branches arising from the sac: a technical note. Neurosurgery 10(Suppl 1):E167–E171. https://doi.org/10.1227/NEU.0000000000000130.

    Article  PubMed  Google Scholar 

  8. Mascitelli JR, Moyle H, Oermann EK et al (2014) An update to the Raymond-Roy occlusion classification of intracranial aneurysms treated with coil embolization. J Neurointerv Surg 7:496–502. https://doi.org/10.1136/neurintsurg-2014-011258

    Article  PubMed  Google Scholar 

  9. Jeon P, Kim BM, Kim DJ et al (2014) Y-configuration double-stent-assisted coiling using two closed-cell stents for wide-neck basilar tip aneurysms. Acta Neurochir 156:1677–1686. https://doi.org/10.1007/s00701-014-2163-0.

    Article  PubMed  Google Scholar 

  10. Machi P, Costata V, Lobotesis K et al (2015) LEO Baby Stent use following balloon-assisted coiling: single- and dual-stent technique--Immediate and midterm results of 29 consecutive patients. AJNR Am J Neuroradiol 36:2096–2103. https://doi.org/10.3174/ajnr.A4413.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Batuhan Kara.

Ethics declarations

Conflict of interest

The authors declare that they have no conflict of interest.

Ethical approval

All procedures performed in the studies involving human participants were in accordance with the ethical standards of the institutional and/or national research committee and with the 1964 Helsinki Declaration and its later amendments or comparable ethical standards.

Informed consent

Informed consent was obtained from all individual participants included in the study.

Additional information

Publisher’s note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Kara, B., Selcuk, H., Kilinc, F. et al. Combination of temporary bridging device (Comaneci) and permanent stenting in the treatment of unruptured wide neck bifurcation aneurysms. Neuroradiology 63, 975–980 (2021). https://doi.org/10.1007/s00234-021-02677-z

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00234-021-02677-z

Keywords

Navigation