Skip to main content
Log in

Improved visualization of superficial temporal artery using segmented time-of-flight MR angiography with venous suppression at 7T

  • Short Report
  • Published:
Neuroradiology Aims and scope Submit manuscript

Abstract

Purpose

To evaluate the quality of time-of-flight MR angiography (TOF-MRA) with venous suppression at 7T on imaging superficial temporal artery (STA).

Methods

A recently developed segmented TOF technique with reduced specific absorption rate (SAR) of venous suppression (VS) module was employed to achieve high-resolution arterial angiography without the contamination of venous signal. Images of segmented TOF with VS at 7T, TOF without VS at 7T, and TOF with VS at 3T were collected on 17 healthy volunteers. The number of STA branches and their local contrast achieved by the three methods were quantified and compared using paired t test.

Results

Segmented TOF with VS at 7T successfully suppressed venous signal without reducing the contrast of arterial angiography. The numbers of STA branches in 7T images were significantly higher than that in 3T images (5.79 vs. 4.50, p < 0.001). The contrast of 7T segmented TOF was significantly higher than 3T TOF (7.21 vs. 5.56, p = 0.006).

Conclusion

Segmented TOF with VS at 7T displayed more branches of STA, while eliminating the signal of superficial temporal vein (STV). The improved visualization of STA will potentially facilitate the pre-operative assessment of STA in STA-MCA bypass surgery.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2

References

  1. von Morze C, Xu D, Purcell DD, Hess CP, Mukherjee P, Saloner D, Kelley DAC, Vigneron DB (2007) Intracranial time-of-flight MR angiography at 7T with comparison to 3T. J Magn Reson Imaging 26:900–904. https://doi.org/10.1002/jmri.21097

    Article  Google Scholar 

  2. Kang CK, Park CW, Han JY, Kim SH, Park CA, Kim KN, Hong SM, Kim YB, Lee KH, Cho ZH (2009) Imaging and analysis of lenticulostriate arteries using 7.0-Tesla magnetic resonance angiography. Magn Reson Med 61:136–144. https://doi.org/10.1002/mrm.21786

    Article  PubMed  Google Scholar 

  3. Cho ZH, Kang CK, Han JY, Kim SH, Kim KN, Hong SM, Park CW, Kim YB (2008) Observation of the lenticulostriate arteries in the human brain in vivo using 7.0T MR angiography. Stroke 39:1604–1606. https://doi.org/10.1161/STROKEAHA.107.508002

    Article  PubMed  Google Scholar 

  4. Duyn JH (2012) The future of ultra-high field MRI and fMRI for study of the human brain. NeuroImage 62:1241–1248. https://doi.org/10.1016/j.neuroimage.2011.10.065

    Article  PubMed  Google Scholar 

  5. Oh BH, Moon HC, Baek HM, Lee YJ, Kim SW, Jeon YJ, Lee GS, Kim HR, Choi JH, Min KS, Lee MS, Kim YG, Kim DH, Kim WS, Park YS (2017) Comparison of 7 T and 3 T MRI in patients with moyamoya disease. Magn Reson Imaging 37:134–138. https://doi.org/10.1016/j.mri.2016.11.019

    Article  PubMed  Google Scholar 

  6. Deng X, Zhang Z, Zhang Y, Zhang D, Wang R, Ye X, Xu L, Wang B, Wang K, Zhao J (2016) Comparison of 7.0- and 3.0-T MRI and MRA in ischemic-type moyamoya disease: preliminary experience. J Neurosurg 124:1716–1725. https://doi.org/10.3171/2015.5.JNS15767

    Article  PubMed  Google Scholar 

  7. Dengler NF, Madai VI, Wuerfel J, von Samson-Himmelstjerna FC, Dusek P, Niendorf T, Sobesky J, Vajkoczy P (2016) Moyamoya vessel pathology imaged by ultra–high-field magnetic resonance imaging at 7.0 T. J Stroke Cerebrovasc Dis 25:1544–1551. https://doi.org/10.1016/j.jstrokecerebrovasdis.2016.01.041

    Article  PubMed  Google Scholar 

  8. Park CA, Kang CK, Kim YB, Cho Z-H (2018) Advances in MR angiography with 7T MRI: from microvascular imaging to functional angiography. NeuroImage 168:269–278. https://doi.org/10.1016/j.neuroimage.2017.01.019

    Article  PubMed  Google Scholar 

  9. Zhang Z, Deng X, Weng D, An J, Zuo Z, Wang B, Wei N, Zhao J, Xue R (2015) Segmented TOF at 7 T MRI: technique and clinical applications. Magn Reson Imaging 33:1043–1050. https://doi.org/10.1016/j.mri.2015.07.002

    Article  PubMed  Google Scholar 

  10. Wrede KH, Johst S, Dammann P, Özkan N, Mönninghoff C, Kraemer M, Maderwald S, Ladd ME, Sure U, Umutlu L, Schlamann M (2014) Improved cerebral time-of-flight magnetic resonance angiography at 7 tesla – feasibility study and preliminary results using optimized venous saturation pulses. PLoS One 9:e106697. https://doi.org/10.1371/journal.pone.0106697

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  11. Rosset A, Spadola L, Ratib O (2004) OsiriX: an open-source software for navigating in multidimensional DICOM images. J Digit Imaging 17:205–216. https://doi.org/10.1007/s10278-004-1014-6

    Article  PubMed  PubMed Central  Google Scholar 

  12. Van de Moortele P-F, Auerbach EJ, Olman C et al (2009) T1 weighted brain images at 7 Tesla unbiased for proton density, T2⁎ contrast and RF coil receive B1 sensitivity with simultaneous vessel visualization. NeuroImage 46:432–446. https://doi.org/10.1016/j.neuroimage.2009.02.009

    Article  PubMed  PubMed Central  Google Scholar 

  13. Hosoda Y, Ikeda E, Hirose S (1997) Histopathological studies on spontaneous occlusion of the circle of Willis (cerebrovascular moyamoya disease). Clin Neurol Neurosurg 99:S203–S208. https://doi.org/10.1016/S0303-8467(97)00044-9

    Article  PubMed  Google Scholar 

  14. Hartkamp NS, van Osch MJP, Kappelle J, Bokkers RPH (2014) Arterial spin labeling magnetic resonance perfusion imaging in cerebral ischemia. Curr Opin Neurol 27:42–53. https://doi.org/10.1097/WCO.0000000000000051

    Article  PubMed  Google Scholar 

  15. Chalela JA, Alsop DC, Gonzalez-Atavales JB, Maldjian JA, Kasner SE, Detre JA (2000) Magnetic resonance perfusion imaging in acute ischemic stroke using continuous arterial spin labeling. Stroke 31:680–687. https://doi.org/10.1161/01.STR.31.3.680

    Article  CAS  PubMed  Google Scholar 

  16. Wang DJJ, Alger JR, Qiao JX, Hao Q, Hou S, Fiaz R, Gunther M, Pope WB, Saver JL, Salamon N, Liebeskind DS, for the UCLA Stroke Investigators (2012) The value of arterial spin-labeled perfusion imaging in acute ischemic stroke: comparison with dynamic susceptibility contrast-enhanced MRI. Stroke 43:1018–1024. https://doi.org/10.1161/STROKEAHA.111.631929

    Article  PubMed  PubMed Central  Google Scholar 

  17. Togao O, Hiwatashi A, Obara M, Yamashita K, Momosaka D, Nishimura A, Arimura K, Hata N, Yoshimoto K, Iihara K, van Cauteren M, Honda H (2018) 4D ASL-based MR angiography for visualization of distal arteries and leptomeningeal collateral vessels in moyamoya disease: a comparison of techniques. Eur Radiol. https://doi.org/10.1007/s00330-018-5462-7

    Article  Google Scholar 

  18. Iryo Y, Hirai T, Nakamura M, Kawano T, Kaku Y, Ohmori Y, Kai Y, Azuma M, Nishimura S, Shigematsu Y, Kitajima M, Yamashita Y (2016) Evaluation of intracranial arteriovenous malformations with four-dimensional arterial-spin labeling–based 3-T magnetic resonance angiography. J Comput Assist Tomogr 40:290–296. https://doi.org/10.1097/RCT.0000000000000346

    Article  PubMed  Google Scholar 

  19. Togao O, Hiwatashi A, Obara M, Yamashita K, Kikuchi K, Kamei R, Nishimura A, Arimura K, Yoshimoto K, Iihara K, van Cauteren M, Honda H (2018) Acceleration-selective arterial spin-labeling MR angiography used to visualize distal cerebral arteries and collateral vessels in moyamoya disease. Radiology 286:611–621. https://doi.org/10.1148/radiol.2017162279

    Article  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Zihao Zhang.

Ethics declarations

Funding

This study was funded by the Beijing Municipal Natural Science Foundation (7184226) Young Elite Scientists Sponsorship Program by CAST (2017QNRC001), and a Ministry of Science and Technology of China grant (No. 2015CB351701).

Conflict of interest

The authors declare that they have no conflict of interest.

Ethical approval

All procedures performed in the studies involving human participants were in accordance with the ethical standards of the institutional and/or national research committee and with the 1964 Helsinki Declaration and its later amendments or comparable ethical standards.

Informed consent

Informed consent was obtained from all individual participants included in the study.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Wei, N., Zhang, Z., An, J. et al. Improved visualization of superficial temporal artery using segmented time-of-flight MR angiography with venous suppression at 7T. Neuroradiology 60, 1243–1246 (2018). https://doi.org/10.1007/s00234-018-2099-9

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00234-018-2099-9

Keywords

Navigation