Abstract
Introduction
There has been concern regarding the usefulness of diffusion-weighted imaging (DWI) to evaluate the ischemic lesions associated with carotid artery stent placement (CAS). Some small lesions may be detected not by standard DWI but by thin-slice DWI alone, since most of the cerebral lesions are very small in size and clinically silent.
The purpose of this study is to compare the detectability of the small ischemic lesions after CAS by standard and thin-slice DWI.
Methods
Both standard DWI with slice thickness of 6 mm and thin-slice DWI with slice thickness of 2 mm were obtained at the same MR examination within 2 to 7 days after 20 procedures of CAS in 17 patients. Number and measured diameter size of the detected lesions on both DWI were compared.
Results
All CAS procedures in 17 patients were successfully completed. The focal ischemic lesions were detected in 14 of 20 on thin-slice DWI and seven examinations on standard DWI. The total numbers of hyperintense lesions were 31 on thin-slice DWI and ten on standard DWI (p < 0.001). The sizes of these ten lesions on thin-slice DWI were larger than those of standard DWI, and the mean size of the thin-slice DWI and that of standard DWI were significantly different (p < 0.005).
Conclusion
Thin-slice DWI was able to detect small cortical lesions better than standard DWI. Thin-slice DWI may be useful to evaluate small silent ischemic lesions after CAS.
Similar content being viewed by others
References
Pinero P, Gonzalez A, Mayol A et al (2006) Silent ischemia after neuroprotected percutaneous carotid stenting: a diffusion-weighted MR study. AJNR Am J Neuroradiol 27:1338–1345
Beauchamp NJ, Ulug AM, Passe TJ et al (1998) MR diffusion imaging in stroke: review and controversies. RadioGraphics 18:1269–1285
Crisostomo RA, Garcia MM, Tong DC (2003) Detection of diffusion-weighted MRI abnormalities in patients with transient ischemic attacks: correlation clinical characteristics. Stroke 34:932–937
Hauth E, Jansen C, Drescher R et al (2005) MR and clinical follow-up of diffusion-weighted cerebral lesions after carotid artery stenting. AJNR Am J Neuroradiol 26:2336–2341
Kidwell CS, Alger JR, Di Salle F et al (1999) Diffusion MRI in patients with transient ischemic attacks. Stroke 30:1174–1180
Lovblad KO, Plushke W, Remonda L et al (2000) Diffusion-weighted MRI for monitoring neurovascular interventions. Neuroradiology 42:134–138
Klotzsch C, Nahser HC, Henkes H et al (1998) Detection of microemboli distal to cerebral aneurysms before and after therapeutic embolization. AJNR Am J Neuroradiol 19:1315–1318
Roh HG, Byun HS, Ryoo JW et al (2005) Prospective analysis of cerebral infarction after carotid endarterectomy and carotid artery stent placement by using diffusion-weighted imaging. AJNR Am J Neuroradiol 26:376–384
Derdeyn CP (2001) Diffusion-weighted imaging as a surrogate marker for stroke as a complication of cerebrovascular procedures and devices. AJNR Am J Neuroradiol 22:1234–1235
Weber J, Mattle HP, Heid O et al (2000) Diffusion-weighted imaging in ischemic stroke: a follow-up study. Neuroradiol 42:184–191
Kruger K, Kugel H, Grond M et al (2000) Late resolution of diffusion-weighted MRI changes in a patient with prolonged reversible ischemic neurological deficit after thrombolytic therapy. Stroke 31:2715–2718
Schluter M, Tubler T, Steffens JC et al (2003) Focal ischemia of the brain after neuroprotected carotid artery stenting. JACC 42:1007–1013
Zwenneke H, Ouhlous M, Hendriks J et al (2004) Cerebral ischemia after carotid intervention. J Endovasc Ther 11:251–257
Jaeger HJ, Mathias KD, Hauth E et al (2002) Cerebral ischemia detected with diffusion-weighted MR imaging after stent implantation in the carotid artery. AJNR Am J Neuroradiol 23:200–207
Cosottini M, Michelassi MC, Puglioli M et al (2005) Silent cerebral ischemia detected with diffusion-weighted imaging in patients treated with protected and unprotected carotid artery stenting. Stroke 36:2389–2393
Conflict of interest statement
We declare that we have no conflict of interest.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Yamatogi, S., Furukawa, M., Iida, E. et al. Evaluation of small ischemic lesions after carotid artery stenting: the usefulness of thin-slice diffusion-weighted MR imaging. Neuroradiology 53, 255–260 (2011). https://doi.org/10.1007/s00234-010-0730-5
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00234-010-0730-5