Predictions of the operating liquid level in the evaporator of a closed two-phase thermosyphon (gravity heat pipe) are given throughout a simplified analysis which takes the influence of the dimension and condensation heat transfer in the condenser of the heat pipe into account. In order to verify the accuracy of our model comparison of the present study with some published results is made by means of computational examples.

Keywords

Heat Pipe Void Fraction Slug Flow Filling Ratio Liquid Pool 
These keywords were added by machine and not by the authors. This process is experimental and the keywords may be updated as the learning algorithm improves.

References

  1. 1.
    Tang ZW, Ma CF, Jiang ZY (2002) Retrospect and prospect about industrial heat pipes. J Beijing Polytech Univ 28(4):465–471 (in Chinese)Google Scholar
  2. 2.
    Roesler S, Groll M (1992) Flow visualization and analytical modeling of interaction phenomena in closed two-phase flow systems. In: Proceedings of the 8th international heat pipe conference, pp 26–32Google Scholar
  3. 3.
    Jiang ZY, Ma TZ, Qin J (1992) Heat transfer and incipient boiling of saturated falling liquid films. In: Proceedings of the 8th international heat pipe conference, pp 77–82Google Scholar
  4. 4.
    Moezawa S, Gi K, Matsumura S (1992) Laminar film condensation on inclined two-phase thermosyphon. In: Proceedings of the 8th international heat pipe conference, pp 214–219Google Scholar
  5. 5.
    Tang ZW, Ma CF, Jiang ZY (2002) Some characteristics of falling liquid film flow boiling. In: Proceedings of the 12th international heat transfer conference, pp 273–278Google Scholar
  6. 6.
    Wallis GB (1969) One-dimensional two-phase flow. McGraw-Hill Book Company, New ZealandGoogle Scholar
  7. 7.
    Liu X, Ma TZ, Zhao JQ (1988) Effects of the filling ratio of working fluids on operating characteristics of the two-phase closed thermosyphon. In: Proceedings of international symposium on phase change heat transfer, pp 551–556Google Scholar
  8. 8.
    He JL, Ma TZ, Zhang ZF (1992) Investigation of boiling liquid pool height of a two-phase closed thermosyphon. In: Proceedings of the 8th international heat pipe conference, pp 154–159Google Scholar