In vitro Mechanical and Cellular Responses of Neonatal Mouse Bones to Loading Using a Novel Micromechanical-Testing Device

  • Published:
Calcified Tissue International Aims and scope Submit manuscript

Mechanical stimulation is critical for the maintenance of bone architecture and bone mass. These effects are dependent on the magnitude, duration, and rate of the mechanical stimuli. The goals of the present study were to develop and optimize a micromechanical-testing device for in vitro mechanical stimulation of whole viable bones, and to identify the physical parameters of loading that elicit maximal anabolic responses. The model was the 7–8-day-old neonatal CD-1 mouse tibia. A range of cyclic strain magnitudes [500–7000 microstrain (me)] and frequencies [0.2–30 hertz (Hz)] were applied to the neonatal bones. Incremental cyclic compression tests showed that the bones were nonlinearly viscoelastic. Bone stiffness and hysteresis energy dissipation were dependent on the maximum load magnitude. DNA and protein synthesis were significantly enhanced in bones that were cyclically loaded at 0.5 Hz/1000 me, 0.5 Hz/2000 me, or l Hz/1000 me, compared to nonloaded controls. Anabolic responses were maximal at a peak load of 100 mN at l Hz/1000 me. Autoradiography of the bones loaded under these conditions showed proliferation of cells at periosteal surfaces. Hysteresis energy per cycle was greatest at loads that caused the largest anabolic responses. The parameters of strain and load that elicit optimal effects on the neonatal bones are comparable to those in other systems, validating the use of the instrumentation for studying the mechanisms of the anabolic responses. The findings also suggest that hysteresis energy per cycle may be a determinant of the anabolic response of bones to mechanical stimulation.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Subscribe and save

Springer+ Basic
$34.99 /Month
  • Get 10 units per month
  • Download Article/Chapter or eBook
  • 1 Unit = 1 Article or 1 Chapter
  • Cancel anytime
Subscribe now

Buy Now

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Kunnel, J., Gilbert, J. & Stern, P. In vitro Mechanical and Cellular Responses of Neonatal Mouse Bones to Loading Using a Novel Micromechanical-Testing Device . Calcif Tissue Int 71, 499–507 (2002). https://doi.org/10.1007/s00223-001-1073-3

Download citation

  • Received:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00223-001-1073-3

Keywords

Navigation