Skip to main content
Log in

Precision-grip force changes in the anatomical and prosthetic limb during predictable load increases

  • Research Note
  • Published:
Experimental Brain Research Aims and scope Submit manuscript

Abstract.

This study examined precision-grip force applied to an instrumented test object held aloft while the weight of the object was predictably varied by transporting and placing loads (50, 100, or 200 g) atop the test object. Transport of the loads was performed either by the subject or the experimenter. Grip force was examined in four non-amputee control subjects and in the anatomical and prosthetic hand of a subject with a prosthetic device. As subjects transported the load, anticipatory grip-force changes occurred in the anatomical hands and prosthetic hand, which were scaled in relation to the load. When the experimenter transported the load to the anatomical hands of control subjects or the prosthetic user, anticipatory increases in grip force occurred that also were scaled in relation to load. However, when the experimenter transported the load to the prosthetic hand, anticipatory grip-force adjustments were absent. During the phase in which the load was being assumed by the postural hand, grip forces in the anatomical hands and prosthetic hand were further scaled to load demands. Ability to adapt grip force in the prosthetic hand during this phase suggested that the subject was utilizing sensory information from the residual limb to adjust grip force. Thus, while anticipatory changes precede the process of adaptation to load changes, actual sensory consequences resulting from added weight remain necessary to fully adapt grip force to load demands, even for the prosthetic user.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Author information

Authors and Affiliations

Authors

Additional information

Electronic Publication

Rights and permissions

Reprints and permissions

About this article

Cite this article

Weeks, D., Wallace, S. & Noteboom, J. Precision-grip force changes in the anatomical and prosthetic limb during predictable load increases. Exp Brain Res 132, 404–410 (2000). https://doi.org/10.1007/s002210000337

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s002210000337