Abstract
A flow injection method was developed for the determination of palladium, based on the reaction of palladium with DBOK-chlorophosphonazo with a detection limit of 0.07 μg/mL and a linear calibration range from 0.1 to 3.2 μg/mL of palladium. The reaction product has a maximum absorption at 630 nm. The method was applied to determine Pd2+ in catalysts and in anode mud samples. The relative error is less than 3% and the recovery of palladium is in the range 95% to 105%