Determination of procaine hydrochloride by ion-pairing flow injection analysis with piezoelectric detection

  • Short communication
  • Published:
Fresenius' Journal of Analytical Chemistry Aims and scope Submit manuscript

Abstract

A fast and simple method for the determination of procaine hydrochloride by ion-pairing flow injection analysis has been developed. It is based on the formation of an ion-pair with sodium dodecyl phenylsulphonate and piezoelectric detection. The calibration curve was linear between 0.02 and 2.00 mg/mL, with a detection limit of 0.01 mg/mL, a relative standard deviation of 0.3% (10 replicates) and a sampling frequency of 120/h. The proposed method has been satisfactorily applied to the determination of procaine hydrochloride in pharmaceutical preparations.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Author information

Authors and Affiliations

Authors

Additional information

Received: 19 August 1996 / Revised: 6 November 1996 / Accepted: 12 December 1996

Rights and permissions

Reprints and permissions

About this article

Cite this article

Mo, Z., Luo, J., Long, X. et al. Determination of procaine hydrochloride by ion-pairing flow injection analysis with piezoelectric detection. Fresenius J Anal Chem 358, 556–558 (1997). https://doi.org/10.1007/s002160050469