Abstract
Microcystins are cyclic heptapeptide hepatotoxins produced by cyanobacteria in freshwater. Sample preparation for the analysis of these cyanotoxins in water from algal blooms can take up to several days due to the matrix complexity and the low detection limits required to comply with current legislation. Moreover, there is a large number of unknown microcystins that could potentially exist in the environment resulting from different amino acid substitutions into the microcystin skeletal structure. To tackle these problems, the present study involved the development of a high throughput method based on on-line solid phase extraction coupled to liquid chromatography that could provide quantitative results for 12 microcystin variants (LR, YR, RR, HtyR, HilR, WR, LW, LA, LF, LY, Dha7-LR, and Dha7-RR) and anatoxin-A in less than 3 h with detection limits between 0.004 and 0.01 μg L−1 and expanded uncertainty between 4 and 14%. Data-dependent acquisition was employed for the non-targeted analysis of these cyanotoxins. Filtering the data based on structure diagnostic fragments, two unknown microcystin variants not previously reported in the literature were detected. The structures Leu1-microcystin-Met(O)R and Leu1-microcystin-LY were fully characterized by accurate mass measurement, collision-induced dissociation, and fragmentation prediction software.
Similar content being viewed by others
References
Loftin KA, Graham JL, Hilborn ED, Lehmann SC, Meyer MT, Dietze JE, Griffith CB. Cyanotoxins in inland lakes of the United States: occurrence and potential recreational health risks in the EPA National Lakes Assessment 2007. Harmful Algae. 2016;56:77–90.
Catherine A, Bernard C, Spoof L, Bruno M. Microcystins and nodularins. In: Meriluoto J, Spoof S, Codd GA, editors. Handbook of cyanobacterial monitoring and cyanotoxin analysis, vol. 11; 2017. p. 109–18.
Yuan M, Carmichael WW, Hilborn ED. Microcystin analysis in human sera and liver from human fatalities in Caruaru, Brazil 1996. Toxicon. 2008;48:627–40.
Azevedo S, Carmichael WW, Jochimsen EM, Rinehart KL, Lau S, Shaw GR, Eaglesham GK. Human intoxication by microcystins during renal dialysis treatment in Caruaru—Brazil. Toxicology. 2002;181-182:441–6.
Carmichael WW, Boyer GL. Health impacts from cyanobacteria harmful algae blooms: implications for the North American Great Lakes. Harmful Algae. 2016;54:194–212.
Osswald J, Rellán S, Gago A, Vasconcelos V. Toxicology and detection methods of the alkaloid neurotoxin produced by cyanobacteria, anatoxin-a. Environ Int. 2007;33:1070–89.
Niedermeyer T. Microcystin congeners described in the literature. Available online: doi:10.6084/m9.figshare.880756. Accessed 13 Feb 2017.
Cyanobacterial toxins: microcystin-LR in drinking-water. Background document for development of WHO guidelines for drinking-water quality. Originally published in Guidelines for drinking-water quality, 2nd ed. Addendum to Vol. 2. Health criteria and other supporting information. World Health Organization, Geneva; 1998.
Ontario drinking water quality standards, schedule 2, chemical standards, Ontario Safe Drinking Water Act; 2002.
Samdal IA, Ballot A, Lovberg KE, Miles CO. Multihapten approach leading to a sensitive ELISA with broad cross-reactivity to microcystins and nodularin. Environ. Sci. Technol. 2014;48(14):8035–43.
Miles CO, Sandvik M, Hezron EN, Rundberget T, Alistair L, Rise F, Ballot A. Thiol derivatization for LC-MS identification of microcystins in complex matrices. Environ Sci Technol. 2012;46(12):8937–44.
Shoemaker JA, Tettenhorst DR, de la Cruz A. EPA method 544: determination of microcystins and nodularin in drinking water by solid phase extraction and liquid chromatography/tandem mass spectrometry (LC/MS/MS). EPA Document #: EPA/600/R-14/474. 2015, version 1.0.
Taguchi V, Jenkins S. The determination of microcystins and anatoxin-A in water by liquid chromatography–(electrospray ionization) tandem mass spectrometry [LC-(ESI) MS/MS]. Ministry of the Environment and Climate Change, LaSB Method E3450. 2016, version 5.1.
Mashile GP, Nomngongo PN. Recent application of solid phase based techniques for extraction and preconcentration of cyanotoxins in environmental matrices. Cr rev Anal Chem. 2017;47(2):119–26.
Foss AJ, Aubel MT. Using the MMPB technique to confirm microcystin concentrations in water measured by ELISA and HPLC (UV, MS, MS/MS). Toxicon. 2015;104:91–101.
Kaloudir T, Zervou SK, Tsimeli K, Triantis TM, Fotiou T, Hiskia A. Determination of microcystins and nodularin (cyanobacterial toxins) in water by LC–MS/MS monitoring of Lake Marathonas, a water reservoir of Athens, Greece. J Hazard Mater. 2013;263:105–15.
Balest L, Murgolo S, Sciancalepore L, Montemurro P, Abis PP, Pastore C, Mascolo G. Ultra-trace levels analysis of microcystins and nodularin in surface water by on-line solid-phase extraction with high-performance liquid chromatography tandem mass spectrometry. Anal Bioanal Chem. 2016;408:4063–71.
Fayad PB, Roy-Lachapelle A, Duy SV, Prévost M, Sauvé S. On-line solid-phase extraction coupled to liquid chromatography tandem mass spectrometry for the analysis of cyanotoxins in algal blooms. Toxicon. 2015;108:167–75.
Beltrán E, Ibáñez M, Sancho JV, Hernández F. Determination of six microcystins and nodularin in surface and drinking waters by on-line solid phase extraction–ultra high pressure liquid chromatography tandem mass spectrometry. J. Chrom. A. 2012;1266:61–8.
Lee HS, Jeong CK, Lee HM, Choi SJ, Do KS, Kim K, Kim YH. On-line trace enrichment for the simultaneous determination of microcystins in aqueous samples using high-performance liquid chromatography with diode-array detection. J Chrom A. 1999; 179–84.
Shan Y, Shi X, Dou A, Zou C, He H, Yang Q, Zhao S, Lu X, Xu G. A fully automated system with on-line micro solid-phase extraction combined with capillary liquid chromatography–tandem mass spectrometry for high throughput analysis of microcystins and nodularin-R in tap water and lake water. J. Chrom. A. 2011;1218:1743–8.
Ortielli D, Edder P, Cognard E, Jan P. Fast screening and quantitation of microcystins in microalgae dietary supplement products and water by liquid chromatography coupled to time of flight mass spectrometry. Anal Chim Acta. 2008; 230–37.
Flores C, Caixach J. An integrated strategy for rapid and accurate determination of free and cell-bound microcystins and related peptides in natural blooms by liquid chromatography–electrospray-high resolution mass spectrometry and matrix-assisted laser desorption/ionization time-of-flight/time-of-flight mass spectrometry using both positive and negative ionization modes. J Chrom a. 2015;1407:76–89.
Hollingdale C, Thomas K, Lewis N, Békri K, McCarron P, Quilliam MA. Feasibility study on production of a matrix reference material for cyanobacterial toxins. Anal Bioanal Chem. 2015;407:5353–63.
Kim IS, Nguyen GH, Kim S, Lee J, Yu HW. Evaluation of methods for cyanobacterial cell lysis and toxin (microcystin-LR) extraction using chromatographic and mass spectrometric analyses. Environ Eng res. 2009;14(4):250–4.
Van den Oetelaar PJM, Mentink IM, Brinks GJ. Loss of peptides and proteins upon sterile filtration due to adsorption to membrane filters. Drug Dev Ind Pharm. 1989;1:96–106.
Matthiensen A, Beattie KA, Yunes JS, Kaya K, Codd GA. [D-Leu1] microcystin-LR, from the cyanobacterium Microcystis RST 9501 and from a Microcystis bloom in the Patos lagoon estuary, Brazil. Phytochemistry. 2000;55(5):383–7.
Molview v2.2 online version: http://molview.org/. Accessed 16 Feb 2017.
Acknowledgements
The authors would like to thank Adam Ladak and Lauren Mullin from Waters for their support and assistance with UNIFI software.
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
The present study did not involve human or animal participants.
Conflict of interest
The authors declare that they have no conflict of interest.
Electronic supplementary material
ESM 1
(PDF 133 kb)
Rights and permissions
About this article
Cite this article
Ortiz, X., Korenkova, E., Jobst, K.J. et al. A high throughput targeted and non-targeted method for the analysis of microcystins and anatoxin-A using on-line solid phase extraction coupled to liquid chromatography–quadrupole time-of-flight high resolution mass spectrometry. Anal Bioanal Chem 409, 4959–4969 (2017). https://doi.org/10.1007/s00216-017-0437-0
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00216-017-0437-0