Abstract
A hydrophilic interaction high-performance liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS) method for determination of 2-pyrrolidinone in swine liver was developed and validated. After the fortification of 2-pyrrolidinone-d6 as the internal standard, 2-pyrrolidinone in swine liver was extracted by acetonitrile, and the supernatant was led through a C18 + WAX mixed-mode solid phase extraction (SPE) cartridge. Furthermore, the eluate was adjusted to pH 5.0 and then led through a strong cationic exchange SPE cartridge. 2-Pyrrolidinone and 2-pyrrolidinone-d6 were concentrated and eluted by acetonitrile containing 2% ammonium hydroxide. The final eluate was acidified and then injected for hydrophilic interaction LC-MS/MS analysis. Mass spectrometry detection was carried using positive turbo-ion spray ionization mode. The multiple reaction monitoring transitions were 86 → 69 for 2-pyrrolidinone and 92 → 75 for 2-pyrrolidinone-d6. The C18 + WAX mixed-mode SPE cleanup greatly prevented the rapid contamination of mass spectrometer. The further SCX SPE cleanup thoroughly eliminated the absolute matrix effect. Solvent calibration standards could be readily used for quantitative analysis of 2-pyrrolidinone with excellent precision and accuracy. Endogenous levels of 2-pyrrolidinone in some blank matrices was readily determined. Full recoveries were readily achieved by the optimize extraction protocol, and thus the role of 2-pyrrolidinone-d6 was to just compensate the variation of the injections. The detection limit was 5 ng g−1 swine liver. The validated method was applied to a depletion study of 2-pyrrolidinone in swine liver following intramuscular administration of a drug 2-pyrrolidinone formulation. The matrix effect from tissue samples usually represented a technical challenge for LC-MS/MS analysis, and a very small molecule such as 2-pyrrolidinone also represented a technical barrier for LC-MS/MS analysis. However, the extraction protocol developed in the present study reached the best outcome: zero matrix effect and full recovery.



Similar content being viewed by others
References
Wikipedia. Available at: http://en.wikipedia.org/wiki/Poly_vinyl_pyrrolidone#Uses
Barry BW (1987) Mode of action of penetration enhancer in human skin. J Control Release 6:85–87
Carnerup MA, Åkesson B, Jönsson BAG (2001) Determination of 5-hydroxy-N-methyl-2-pyrrolidone and 2-hydroxy-N-methylsuccinimide in human plasma and urine using liquid chromatography–electrospray tandem mass spectrometry. J Chromatogr B 761:107–113
Carnerup MA, Saillenfait AM, Jönsson BAG (2005) Concentrations of N-methyl-2-pyrrolidone (NMP) and its metabolites in plasma and urine following oral administration of NMP to rats. Food Chem Toxicol 43:1441–1447
Carnerup MA, Spanne M, Jönsson BAG (2006) Levels of N-methyl-2-pyrrolidone (NMP) and its metabolites in plasma and urine from volunteers after experimental exposure to NMP in dry and humid air. Toxicol Lett 162:139–145
Cohen AS, Jönsson BAG (2007) Automated solid-phase extraction and liquid chromatography tandem mass spectrometry determination of N-methyl-2-pyrrolidone and its metabolites in urine and plasma. Chromatographia 65:407–412
Kubota R, Endo Y, Takeuchi A, Inoue Y, Ogata H, Ogawa M, Nakagawa T, Onda N, Endo G (2007) SPE-GC/FTD determination of N-methyl-2-pyrrolidone and its metabolites in urine. J Chromatogr B 854:204–210
Mehdinia A, Ghassempour A, Rafati H, Heydari R (2007) Determination of N-vinyl-2-pyrrolidone and N-methyl-2-pyrrolidone in drugs using polypyrrole-based headspace solid-phase microextraction and gas chromatography-nitrogen-phosphorous detection. Anal Chim Acta 587:82–88
Schenck FJ, Lehotay SJ (2000) Does further clean-up reduce the matrix enhancement effect in gas chromatographic analysis of pesticide residues in food? J Chromatogr A 868:51–61
He Y, Liu YH (2007) Assessment of primary and secondary amine adsorbents and elution solvents with or without graphitized carbon for the SPE clean-up of food extracts in pesticide residue analysis. Chromatographia 65:581–589
Matuszewski BK, Constanzer ML, Chavez-Eng CM (2003) Strategies for the assessment of matrix effect in quantitative bioanalytical methods based on HPLC-MS/MS. Anal Chem 75:3019–3030
Shen JX, Motyka RJ, Roach JP, Hayes RN (2005) Minimization of ion suppression in LC–MS/MS analysis through the application of strong cation exchange solid-phase extraction (SCX-SPE). J Pharm Biomed Anal 37:359–367
Muller C, Schafer P, Stortzel M, Vogt S, Weinmann W (2002) Ion suppression effects in liquid chromatography–electrospray-ionisation transport-region collision induced dissociation mass spectrometry with different serum extraction methods for systematic toxicological analysis with mass spectra libraries. J Chromatogr B 773:47–52
Franke JP, de Zeeuw RA (1998) Solid-phase extraction procedures in systematic toxicological analysis. J Chromatogr B 713:51–59
Liu YH (2006) Use of an improved version of C-8 + SCX mixed mode solid phase extraction material for clean extraction and recovery of basic and zwitterionic compounds from biological fluids. J Liq Chromatogr Relat Technol 29:1405–1429
Liu YH, Zhang WH, Yang YH (2008) Validated hydrophilic interaction LC–MS/MS method for simultaneous quantification of dacarbazine and 5-amino-4-imidazole-carboxamide in human plasma. Talanta 77:412–421
Bennett P, van Horne KC (2003) Identification of the major endogenous and persistent compounds in plasma, serum, and tissue that cause matrix effects with electrospray LC/MS techniques. AAPS Annual Meeting and Exposition, Salt Lake City
Author information
Authors and Affiliations
Corresponding authors
Rights and permissions
About this article
Cite this article
Liu, Y., Chen, X., Ji, Y. et al. Validated hydrophilic interaction LC-MS/MS method for determination of 2-pyrrolidinone residue: applied to a depletion study of 2-pyrrolidinone in swine liver. Anal Bioanal Chem 399, 1371–1380 (2011). https://doi.org/10.1007/s00216-010-4395-z
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00216-010-4395-z