Skip to main content
Log in

Online SAXS investigations of polymeric hollow fibre membranes

  • Special Issue Paper
  • Published:
Analytical and Bioanalytical Chemistry Aims and scope Submit manuscript

Abstract

Polymeric membranes are used in industrial and analytical separation techniques. In this study small-angle X-ray scattering (SAXS) with synchrotron radiation has been applied for in-situ characterisation during formation of polymeric membranes. The spinning of a polyetherimide (PEI) hollow fibre membrane was chosen for investigation of dynamic aggregation processes during membrane formation, because it allows the measurement of the dynamic equilibrium at different distances from the spinning nozzle. With this system it is possible to resolve structural changes in the nm-size range which occur during membrane formation on the time-scale of milliseconds. Integral structural parameters, like radius of gyration and pair-distance distribution, were determined. Depending on the chosen spinning parameters, e.g. the flow ratio between polymer solution and coagulant water, significant changes in the scattering curves have been observed. The data are correlated with the distance from the spinning nozzle in order to get information about the kinetics of membrane formation which has fundamental influence on structure and properties of the membrane.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1.
Fig. 2.
Fig. 3.
Fig. 4.
Fig. 5.
Fig. 6.
Fig. 7.
Fig. 8.
Fig. 9.

Similar content being viewed by others

References

  1. Nunes SP, Peinemann KV (2001) (eds) Membrane technology in the chemical industry. Wiley–VCH, Weinheim

  2. Strathmann H (2001) AICHE J 47:1077–1087

    CAS  Google Scholar 

  3. Anon (2002) Filtr Sep 39:26–27

    Google Scholar 

  4. Mulder MHV (1991) Basic principles of membrane technology. Kluwer, London

  5. Albrecht W, Weigel T, Schossig-Tiedemann M, Kneifel K, Peinemann KV, Paul D (2001) J Membr Sci 192:217–230

    Article  CAS  Google Scholar 

  6. Nunes SP (1997) TRIP 5:187–192

    CAS  Google Scholar 

  7. Nunes SP, Inoue T (1996) J Membr Sci 111:93–103

    Article  CAS  Google Scholar 

  8. Glatter O, Kratky O (1982) Small-angle X-ray scattering. Academic Press, New York

  9. Russell TP (1991) In: Brown GS, Moncton DE (ed) Handbook of synchrotron radiation, vol 3. North–Holland, Amsterdam

  10. Elsner G, Riekel C, Zachmann HG (1985) Adv Polym Sci 67:1–57

    CAS  Google Scholar 

  11. Gehrke R (1992) Rev Sci Instrum 63:455–458

    Article  Google Scholar 

  12. Kneifel K, Peinemann KV (1992) J Membr Sci 65:295–307

    Article  CAS  Google Scholar 

  13. Svergun DI, Semenyuk AV (1991) J Appl Cryst 24:537

    Article  Google Scholar 

Download references

Acknowledgments

The authors express thanks to Sabine Cunis and Andreas Meyer for their important support during the measuring times at HASYLAB/DESY and to Michael Schossig for provision of the SEM picture of the hollow fibre membrane.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to P. Klaus Pranzas.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Pranzas, P.K., Knöchel, A., Kneifel, K. et al. Online SAXS investigations of polymeric hollow fibre membranes. Anal Bioanal Chem 376, 602–607 (2003). https://doi.org/10.1007/s00216-003-1986-y

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00216-003-1986-y

Keywords

Navigation