Skip to main content
Log in

Nonmetals in the argon–inductively coupled plasma–optical emission spectrometry: I. Phosphorus, sulfur and carbon

  • Special Issue Paper
  • Published:
Fresenius' Journal of Analytical Chemistry Aims and scope Submit manuscript

Abstract

The behavior of phosphorus, sulfur and carbon in the argon–ICP–OES was systematically investigated for a wide range of nebulizer gas flows and observation heights. Five lines of phosphorus, four lines of sulfur and three lines of carbon, which have analytical usable detection limits, were taken into consideration. The further parameter set was inspired by the needs of every-day-analysis in the laboratory, especially the low integration time that is necessary for analysis of large amounts of samples. For each element line a signal-to-noise plot was obtained with a method described earlier. The optimum conditions for the combined analysis were determined from signal-to-noise plots of those element lines with the lowest detection limits. The lowest detection limits for phosphorus (0.13 mg/L) and carbon (0.01 mg/L) are useful for solving many analytical problems. However, even the best detection limit for sulfur (2.97 mg/L) is only of limited use without further preconcentration. A major problem was the background of carbon, most probably from carbon dioxide, which increased the available detection limit to about 0.04 mg/L. Surprisingly, the best detection limits were obtained at very low observation heights, which were only a couple of millimeters above the load coil. Fortunately, all elements showed a similar behavior and so the detection limits at compromise conditions were only slightly higher compared with the single-element detection limits.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Subscribe and save

Springer+
from $39.99 /Month
  • Starting from 10 chapters or articles per month
  • Access and download chapters and articles from more than 300k books and 2,500 journals
  • Cancel anytime
View plans

Buy Now

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Explore related subjects

Discover the latest articles and news from researchers in related subjects, suggested using machine learning.

Author information

Authors and Affiliations

Authors

Additional information

Electronic Publication

Rights and permissions

Reprints and permissions

About this article

Cite this article

Knauthe, B., Otto, M. Nonmetals in the argon–inductively coupled plasma–optical emission spectrometry: I. Phosphorus, sulfur and carbon. Fresenius J Anal Chem 371, 1052–1056 (2001). https://doi.org/10.1007/s00216-001-1103-z

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00216-001-1103-z

Keywords