Electrical Engineering

, Volume 100, Issue 2, pp 581–605 | Cite as

A review of condition monitoring techniques and diagnostic tests for lifetime estimation of power transformers

  • Md Mominul Islam
  • Gareth Lee
  • Sujeewa Nilendra Hettiwatte
Original Paper

Abstract

Power transformers are a key component of electrical networks, and they are both expensive and difficult to upgrade in a live network. Many utilities monitor the condition of the components that make up a power transformer and use this information to minimize the outage and extend the service life. Routine and diagnostic tests are currently used for condition monitoring and appraising the ageing and defects of the core, windings, bushings and tap changers of power transformers. To accurately assess the remaining life and failure probability, methods have been developed to correlate results from different routine and diagnostic tests. This paper reviews established tests such as dissolved gas analysis, oil characteristic tests, dielectric response, frequency response analysis, partial discharge, infrared thermograph test, turns ratio, power factor, transformer contact resistance, and insulation resistance measurements. It also considers the methods widely used for health index, lifetime estimation, and probability of failure. The authors also highlight the strengths and limitations of currently available methods. This paper summarizes a wide range of techniques drawn from industry and academic sources and contrasts them in a unified frame work.

Keywords

Power transformers Condition monitoring Asset management Diagnostic tests Residual life 

References

  1. 1.
    Jahromi A et al (2009) An approach to power transformer asset management using health index. IEEE Electr Insul Mag 2(25):20–34CrossRefGoogle Scholar
  2. 2.
    Saha TK, Purkait P (2004) Investigation of an expert system for the condition assessment of transformer insulation based on dielectric response measurements. IEEE Trans Power Deliv 19(3):1127–1134CrossRefGoogle Scholar
  3. 3.
    Gockenbach E, Borsi H (2008) Condition monitoring and diagnosis of power transformers. In: International conference on condition monitoring and diagnosis, 2008. CMD 2008. IEEEGoogle Scholar
  4. 4.
    Zhang X, Gockenbach E (2008) Asset-management of transformers based on condition monitoring and standard diagnosis [feature article]. IEEE Electr Insul Mag 24(4):26–40CrossRefGoogle Scholar
  5. 5.
    Florian Predl MR (2015) Case studies on tap changer diagonostics using dynamic winding resistance measurement. Omicron Seminar, Perth, WAGoogle Scholar
  6. 6.
    Ashkezari AD et al (2011) Evaluating the accuracy of different DGA techniques for improving the transformer oil quality interpretation. In: Universities power engineering conference (AUPEC) 2011 21st AustralasianGoogle Scholar
  7. 7.
    Arakelian V (2002) Effective diagnostics for oil-filled equipment. IEEE Electr Insul Mag 6(18):26–38CrossRefGoogle Scholar
  8. 8.
    Guidelines for life management techniques for power transformers, CIGRE. Technical Brochure 227 (2003)Google Scholar
  9. 9.
    IEEE guide for the interpretation of gases generated in oil-immersed transformers. IEEE Std C57.104 (2008)Google Scholar
  10. 10.
    Tenbohlen S, Figel F (2000) On-line condition monitoring of power transformers. In: Power engineering society winter meeting, 2000. IEEEGoogle Scholar
  11. 11.
    IEEE guide for the interpretation of gases generated in oil-immersed transformer. IEEE Std C57.104 (1991)Google Scholar
  12. 12.
    Akbari A et al (2008) A software implementation of the Duval Triangle method. In: Conference record of the 2008 IEEE international symposium on electrical insulation, 2008. ISEI 2008Google Scholar
  13. 13.
    IEC International Standard for Mineral oil-impregnated electrical equipment in service—guide to the interpretation of dissolved and free gas analysis. International Electrotechnical Commission, IEC60599:2.1 (2007)Google Scholar
  14. 14.
    Hettiwatte SN, Fonseka HA (2012) Analysis and interpretation of dissolved gases in transformer oil: a case study. In: 2012 International conference on condition monitoring and diagnosis (CMD)Google Scholar
  15. 15.
    Islam MM, Lee G, Hettiwatte SN (2016) A nearest neighbour clustering approach for incipient fault diagnosis of power transformers. Electr Eng. doi: 10.1007/s00202-016-0481-3
  16. 16.
    Abu-Elanien AEB, Salama MMA, Ibrahim M (2011) Determination of transformer health condition using artificial neural networks. In: 2011 International symposium on innovations in intelligent systems and applications (INISTA)Google Scholar
  17. 17.
    Pal M, Foody GM (2010) Feature selection for classification of hyperspectral data by SVM. IEEE Trans Geosci Remote Sens 48(5):2297–2307CrossRefGoogle Scholar
  18. 18.
    Abu-Elanien AEB, Salama MMA, Ibrahim M (2012) Calculation of a health index for oil-immersed transformers rated under 69 kV using fuzzy logic. IEEE Trans Power Deliv 27(4):2029–2036CrossRefGoogle Scholar
  19. 19.
    Bakar NA, Abu-Siada A (2016) Fuzzy logic approach for transformer remnant life prediction and asset management decision. IEEE Trans Dielectr Electr Insul 23(5):3199–3208CrossRefGoogle Scholar
  20. 20.
    Islam MM, Lee G, Hettiwatte SN (2016) Incipient fault diagnosis in power transformers by clustering and adapted KNN. In: 2016 Australasian Universities power engineering conference (AUPEC)Google Scholar
  21. 21.
    IEC, Measurement of relative permittivity, dielectric dissipation factor and d.c. resistivity of insulating liquids, IEC 60247 Ed. 2.0 (2004)Google Scholar
  22. 22.
    Ashkezari AD et al (2013) Application of fuzzy support vector machine for determining the health index of the insulation system of in-service power transformers. IEEE Trans Dielectr Electr Insul 20(3):965–973CrossRefGoogle Scholar
  23. 23.
    IEC, Insulating liquids—Determination of acidity—Part 1: automatic potentiometric titration, IEC 62021-1 (2003)Google Scholar
  24. 24.
    Rouse TO (1998) Mineral insulating oil in transformers. IEEE Electr Insul Mag 14(3):6–16CrossRefGoogle Scholar
  25. 25.
    Baka NA et al (2015) A new technique to measure interfacial tension of transformer oil using UV-Vis spectroscopy. IEEE Trans Dielectr Electr Insul 22(2):1275–1282CrossRefGoogle Scholar
  26. 26.
    Li Y et al (2016) Molecular dynamics simulation of temperature impact on the viscosity of transformer oil-based nanofluids. In: 2016 International conference on condition monitoring and diagnosis (CMD)Google Scholar
  27. 27.
    IEEE guide for the reclamation of insulating oil and criteria for its use, IEEE Std. 637 (2007)Google Scholar
  28. 28.
    Utami N et al (2009) Evaluation condition of transformer based on infrared thermography results. In: IEEE 9th international conference on the properties and applications of dielectric materials, 2009. ICPADM 2009. IEEEGoogle Scholar
  29. 29.
    Saha T, Purkait P (2008) Understanding the impacts of moisture and thermal ageing on transformer’s insulation by dielectric response and molecular weight measurements. IEEE Trans Dielectr Electr Insul 15(2):568–582CrossRefGoogle Scholar
  30. 30.
    IEEE guide for loading mineral–oil-immersed transformers, IEEE Std. C57.91 (2002)Google Scholar
  31. 31.
    Wang M, Vandermaar A, Srivastava KD (2002) Review of condition assessment of power transformers in service. IEEE Electr Insul Mag 18(6):12–25CrossRefGoogle Scholar
  32. 32.
    IEEE standard test code for liquid-immersed distribution, power, and regulating transformers, IEEE Std. C57.12.90 (2006)Google Scholar
  33. 33.
    Malik H, Azeem A, Jarial R (2012) Application research based on modern-technology for transformer health index estimation. In: 2012 9th International multi-conference on systems, signals and devices (SSD). IEEEGoogle Scholar
  34. 34.
    Torkaman H, Karimi F (2015) Measurement variations of insulation resistance/polarization index during utilizing time in HV electrical machines—a survey. Measurement 59:21–29CrossRefGoogle Scholar
  35. 35.
    Xiao L et al (2013) Influence of aging degree on polarization and depolarization currents of oil-paper insulation. In: 2013 Annual report conference on electrical insulation and dielectric phenomenaGoogle Scholar
  36. 36.
    Baral A, Chakravorti S (2014) Prediction of moisture present in cellulosic part of power transformer insulation using transfer function of modified debye model. IEEE Trans Dielectr Electr Insul 21(3):1368–1375CrossRefGoogle Scholar
  37. 37.
    Florkowski M, Furgal J (2003) Detection of transformer winding deformations based on the transfer function—measurements and simulations. Meas Sci Technol 14(11):1986CrossRefGoogle Scholar
  38. 38.
    Leibfried T, Feser K (1999) Monitoring of power transformers using the transfer function method. IEEE Trans Power Deliv 14(4):1333–1341CrossRefGoogle Scholar
  39. 39.
    Bigdeli M, Vakilian M, Rahimpour E (2011) A new method for detection and evaluation of winding mechanical faults in transformer through transfer function measurements. Adv Electr Comput Eng 11(2):23–30CrossRefGoogle Scholar
  40. 40.
    Jakob F et al (2003) Use of gas concentration ratios to interpret LTC and OCB dissolved gas data. In: Electrical insulation conference and electrical manufacturing and coil winding technology conference, 2003. Proceedings. IEEEGoogle Scholar
  41. 41.
    Sans JR, Bilgin KM, Kelly JJ (1998) Large-scale survey of furanic compounds in operating transformers and implications for estimating service life. In: Conference record of the 1998 IEEE international symposium on electrical insulation, 1998Google Scholar
  42. 42.
    Stebbins RD, Myers DS, Shkolnik AB (2003) Furanic compounds in dielectric liquid samples: review and update of diagnostic interpretation and estimation of insulation ageing. In: Proceedings of the 7th international conference on properties and applications of dielectric materials, 2003Google Scholar
  43. 43.
    Dervos CT et al (2006) Dielectric spectroscopy and gas chromatography methods applied on high-voltage transformer oils. IEEE Trans Dielectr Electr Insul 13(3):586–592CrossRefGoogle Scholar
  44. 44.
    Poniran Z, Malek ZA (2007) Life assessment of power transformers via paper ageing analysis. In: 2007 International conference on power engineering, energy and electrical drivesGoogle Scholar
  45. 45.
    McDermid W, Grant D (2008) Use of furan-in-oil analysis to determine the condition of oil filled power transformers. In: 2008 International conference on condition monitoring and diagnosisGoogle Scholar
  46. 46.
    Norazhar AB, Abu-Siada A, Islam SA (2013) Review on chemical diagnosis techniques for transformer paper insulation degradation. In: Power engineering conference (AUPEC), 2013 Australasian UniversitiesGoogle Scholar
  47. 47.
    Baird PJ et al (2006) Non-destructive measurement of the degradation of transformer insulating paper. IEEE Trans Dielectr Electr Insul 13(2):309–318CrossRefGoogle Scholar
  48. 48.
    Das N, Abu-Siada A, Islam S (2013) Impact of conducting materials on furan-spectral correlation of transformer oil. In: 2013 Australasian Universities power engineering conference (AUPEC)Google Scholar
  49. 49.
    Abu-Elanien AE, Salama M (2010) Asset management techniques for transformers. Electr Power Syst Res 80(4):456–464CrossRefGoogle Scholar
  50. 50.
    Saha TK (2003) Review of modern diagnostic techniques for assessing insulation condition in aged transformers. IEEE Trans Dielectr Electr Insul 10(5):903–917CrossRefGoogle Scholar
  51. 51.
    Ali M et al (1996) Measuring and understanding the ageing of kraft insulating paper in power transformers. IEEE Electr Insul Mag 12(3):28–34CrossRefGoogle Scholar
  52. 52.
    Yi C et al (2015) Understanding moisture dynamics and its effect on the dielectric response of transformer insulation. IEEE Trans Power Deliv 30(5):2195–2204CrossRefGoogle Scholar
  53. 53.
    Martin D, Perkasa C, Lelekakis N (2013) Measuring paper water content of transformers: a new approach using cellulose isotherms in nonequilibrium conditions. IEEE Trans Power Deliv 28(3):1433–1439CrossRefGoogle Scholar
  54. 54.
    Ekanayake C et al (2006) Frequency response of oil impregnated pressboard and paper samples for estimating moisture in transformer insulation. IEEE Trans Power Deliv 21(3):1309–1317CrossRefGoogle Scholar
  55. 55.
    Talib MA et al (2003) Diagnosis of transformer insulation condition using recovery voltage measurements. In: Power engineering conference, 2003. PECon 2003. Proceedings. National. IEEEGoogle Scholar
  56. 56.
    Bitam-Megherbi F, Mekious M, Megherbi M (2013) A recovery voltage as non-destructive tool for moisture appreciation of oil impregnated pressboard: an approach for power transformers testing. Int J Electr Eng Inform 5(4):422–432Google Scholar
  57. 57.
    Bognar A et al (1990) Diagnostic tests of high voltage oil-paper insulating systems (in particular transformer insulation) using DC dielectrometrics. Proc CIGRE 90:33-08Google Scholar
  58. 58.
    Gubanski SM, Boss P, Csépes G, Houhanessian VD (2003) Dielectric response methods for diagnostics of power transformers. IEEE Electr Insul Mag 19(3):12–18CrossRefGoogle Scholar
  59. 59.
    Saha TK, Purkait P (2004) Investigation of polarization and depolarization current measurements for the assessment of oil-paper insulation of aged transformers. IEEE Trans Dielectr Electr Insul 11(1):144–154CrossRefGoogle Scholar
  60. 60.
    Gafvert U et al (2000) Dielectric spectroscopy in time and frequency domain applied to diagnostics of power transformers. In: Proceedings of the 6th international conference on properties and applications of dielectric materials, 2000Google Scholar
  61. 61.
    Jamail NAM, Piah MAM, Muhamad NA (2011) Comparative study on conductivity using polarization and depolarization current (PDC) test for HV insulation. In: 2011 International conference on electrical engineering and informatics (ICEEI)Google Scholar
  62. 62.
    Silva HAP, Bassi W, Diogo ACT (2004) Noninvasive ageing assessment by means of polarization and depolarization currents analysis and its correlation with moisture content for power transformer life management. In: Transmission and distribution conference and exposition: Latin America, 2004 IEEE/PESGoogle Scholar
  63. 63.
    Yao ZT, Saha TK (2002) Analysis and modeling of dielectric responses of power transformer insulation. In: Power engineering society summer meeting, 2002 IEEE. IEEEGoogle Scholar
  64. 64.
    Jonscher AK (1999) Dielectric relaxation in solids. J Phys D Appl Phys 32(14):R57CrossRefGoogle Scholar
  65. 65.
    Jaya M, Leibfried T, Koch M (2010) Information within the dielectric response of power transformers for wide frequency ranges. In: Conference record of the 2010 IEEE international symposium on electrical insulation (ISEI). IEEEGoogle Scholar
  66. 66.
    Liao R et al (2015) Extraction of frequency domain dielectric characteristic parameter of oil-paper insulation for transformer condition assessment. Electr Power Compon Syst 43(5):578–587CrossRefGoogle Scholar
  67. 67.
    Koch M, Prevost T (2012) Analysis of dielectric response measurements for condition assessment of oil-paper transformer insulation. IEEE Trans Dielectr Electr Insul 19(6):1908–1915CrossRefGoogle Scholar
  68. 68.
    Santos E, Elms M, Jabiri Z (2013) End management of power transformers–operational perspective,” unpublished, presented at the Omicron Seminar, Perth, AustraliaGoogle Scholar
  69. 69.
    Liu J et al (2015) Condition evaluation for aging state of transformer oil-paper insulation based on time-frequency domain dielectric characteristics. Electr Power Compon Syst 43(7):759–769CrossRefGoogle Scholar
  70. 70.
    Hui W, Chengrong L, Huimin H (2010) Influence of temperature to developing processes of surface discharges in oil-paper insulation. In: Conference record of the 2010 IEEE international symposium on electrical insulation (ISEI)Google Scholar
  71. 71.
    Wang H et al (2009) Experimental study on the evolution of surface discharge for oil-paper insulation in transformers. In: IEEE conference on electrical insulation and dielectric phenomena, 2009. CEIDP ’09Google Scholar
  72. 72.
    Chen X, Cavallini A, Montanari GC (2008) Improving high voltage transformer reliability through recognition of pd in paper/oil systems. In: International conference on high voltage engineering and application, 2008. ICHVE 2008Google Scholar
  73. 73.
    Sarathi R et al (2014) Influence of harmonic AC voltage on surface discharge formation in transformer insulation. IEEE Trans Dielectr Electr Insul 21(5):2383–2393CrossRefGoogle Scholar
  74. 74.
    Pinpart T, Judd MD (2009) Experimental comparison of UHF sensor types for PD location applications. In: 2009 IEEE electrical insulation conferenceGoogle Scholar
  75. 75.
    Tenbohlen S et al (2008) Partial discharge measurement in the ultra high frequency (UHF) range. IEEE Trans Dielectr Electr Insul 15(6):1544–1552CrossRefGoogle Scholar
  76. 76.
    Yaacob MM, Alsaedi MA, Rashed JR, Dakhil AM, Atyah SF (2014) Review on partial discharge detection techniques related to high voltage power equipment using different sensors. Photonic Sens 4(4):325–337CrossRefGoogle Scholar
  77. 77.
    Boggs S (1990) Partial discharge: overview and signal generation. IEEE Electr Insul Mag 6(4):33–39CrossRefGoogle Scholar
  78. 78.
    Janus P (2012) Acoustic emission properties of partial discharges in the time-domain and their applications. School of Electrical Engineering, Kungliga Tekniska Hogskolan, StockholmGoogle Scholar
  79. 79.
    Howells E, Norton E (1978) Detection of partial discharges in transformers using acoustic emission techniques. IEEE Trans Power Appar Syst PAS–97(5):1538–1549CrossRefGoogle Scholar
  80. 80.
    Akbari A et al (2002) Transfer function-based partial discharge localization in power transformers: a feasibility study. IEEE Electr Insul Mag 18(5):22–32CrossRefGoogle Scholar
  81. 81.
    Niasar MG (2012) Partial discharge signatures of defects in insulation systems consisting of oil and oil-impregnated paper. Royal Institute of Technology (KTH), Stockholm, pp 33–35Google Scholar
  82. 82.
    Gautschi D, TW, Buchs G (2012) Ultra high frequency (UHF) partial discharge detection for power transformers: sensitivity check on 800 MVA power transformers and first field experience Cigre paperGoogle Scholar
  83. 83.
    Yaacob MM, Alsaedi MA, Rashed JR (2014) Review on partial discharge detection techniques related to high voltage power equipment using different sensors. Springer 4(4):325–337Google Scholar
  84. 84.
    Markalous SM, Tenbohlen S, Feser K (2008) Detection and location of partial discharges in power transformers using acoustic and electromagnetic signals. IEEE Trans Dielectr Electr Insul 15(6):1576–1583CrossRefGoogle Scholar
  85. 85.
    Schwarz R, Muhr M, Pack S (2005) Partial discharge detection in oil with optical methods. In: IEEE International conference on dielectric liquids, 2005. ICDL 2005Google Scholar
  86. 86.
    Karmakar S, Roy NK, Kumbhakar P (2009) Monitoring of high voltage power transformer using direct optical partial discharge detection technique. Springer 38(4):207–215Google Scholar
  87. 87.
    Ariastina WG et al (2009) Condition monitoring of power transformer: a field experience. In: IEEE 9th international conference on the properties and applications of dielectric materials, 2009. ICPADM 2009Google Scholar
  88. 88.
    Blackburn, TR et al (1998) On-line partial discharge measurement on instrument transformers. In: Proceedings of 1998 international symposium on electrical insulating materials, 1998Google Scholar
  89. 89.
    Akbari A et al (2001) High frequency transformer model for computation of sectional winding transfer functions used for partial discharge localization. In: Proceedings of the 12th international symposium on high voltage engineering, Bangalore, IndiaGoogle Scholar
  90. 90.
    Werle P et al (2001) Localisation and evaluation of partial discharges on power transformers using sectional winding transfer functions. In: 12th International symposium on high voltage engineering (ISH), Bangalore, IndiaGoogle Scholar
  91. 91.
    Gockenbach E, Borsi H (2008) Transfer function as tool for noise suppression and localization of partial discharges in transformers during on-site measurements. In: International conference on condition monitoring and diagnosis, 2008. CMD 2008Google Scholar
  92. 92.
    Tenbohlen S et al (2000) Enhanced diagnosis of power transformers using on-and off-line methods: results, examples and future trends. CIGRE paper: 12-204Google Scholar
  93. 93.
    IEEE guide for diagnostic field testing of electric power apparatus—part 1: oil filled power transformers, regulators, and reactors. IEEE Std 62-1995 (1995), pp 1–64Google Scholar
  94. 94.
    Transformers—part, 5: ability to withstand short circuit. IEC Standard, 2000: 60076-5Google Scholar
  95. 95.
    Jayasinghe JASB et al (2006) Winding movement in power transformers: a comparison of FRA measurement connection methods. IEEE Trans Dielectr Electr Insul 13(6):1342–1349CrossRefGoogle Scholar
  96. 96.
    Behjat V, Tamjidi V (2015) Leakage inductance behavior of power transformer windings under mechanical faults. In: Proceedings of the international conference on information technology and computer engineering (ITCE), ITCE’15Google Scholar
  97. 97.
    Bagheri M et al (2013) Frequency response analysis and short-circuit impedance measurement in detection of winding deformation within power transformers. IEEE Electr Insul Mag 29(3):33–40CrossRefGoogle Scholar
  98. 98.
    Secue JR, Mombello E (2008) Sweep frequency response analysis (SFRA) for the assessment of winding displacements and deformation in power transformers. Electr Power Syst Res 78(6):1119–1128CrossRefGoogle Scholar
  99. 99.
    Patel K et al (2013) Power transformer winding fault analysis using transfer function. In: 2013 Australasian Universities power engineering conference (AUPEC)Google Scholar
  100. 100.
    Rahimpour E et al (2000) Modellierung der Transformatorwicklung zur Berechnung der Ubertragungsfunktion fur die Diagnose von Transformatoren. Elektrie 54(1–2):18–30Google Scholar
  101. 101.
    Dick EP, Erven CC (1978) Transformer diagnostic testing by frequency response analysis. IEEE Trans Power Appar Syst PAS–97(6):2144–2153CrossRefGoogle Scholar
  102. 102.
    Pham DAK et al (2012) FRA-based transformer parameters at low frequencies. In: ICHVE 2012—2012 international conference on high voltage engineering and application 2012Google Scholar
  103. 103.
    Prevost T (2015) Power transformer insulation diagnostics, Omicron Seminar, Perth, WAGoogle Scholar
  104. 104.
    Birlasekaran S, Fetherston F (1999) Off/on-line FRA condition monitoring technique for power transformer. IEEE Power Eng Rev 19(8):54–56CrossRefGoogle Scholar
  105. 105.
    ANSI/IEEE C57.91, IEEE guide for loading mineral-oil-immersed transformers (1995)Google Scholar
  106. 106.
    John J, Winders J (2002) Allentown. Marcel Dekker Inc, PennsylvaniaGoogle Scholar
  107. 107.
    IEEE guide for loading mineral-oil-immersed transformers, IEEE Std C57.91 (1996)Google Scholar
  108. 108.
    Bai CF, Gao WS, Liu T (2013) Analyzing the impact of ambient temperature indicators on transformer life in different regions of Chinese Mainland. Sci World J 2013:125896Google Scholar
  109. 109.
    Schaut A, Autru S, Eeckhoudt S (2011) Applicability of methanol as new marker for paper degradation in power transformers. IEEE Trans Dielectr Electr Insul 18(2):533–540CrossRefGoogle Scholar
  110. 110.
    Wouters PAAF, Schijndel AV, Wetzer JM (2011) Remaining lifetime modeling of power transformers: individual assets and fleets. IEEE Electr Insul Mag 27(3):45–51CrossRefGoogle Scholar
  111. 111.
    Gorgan B et al (2012) Calculation of the remaining lifetime of power transformers paper insulation. In: 2012 13th International conference on optimization of electrical and electronic equipment (OPTIM)Google Scholar
  112. 112.
    Martin D et al (2015) An updated model to determine the life remaining of transformer insulation. IEEE Trans Power Deliv 30(1):395–402CrossRefGoogle Scholar
  113. 113.
    Emsley AM (2000) Degradation of cellulosic insulation in power transformers. Part 3: effects of oxygen and water on ageing in oil. IEE Proc Sci Meas Technol 147(3):115–119CrossRefGoogle Scholar
  114. 114.
    M E (2015) Life cycle management of power transformers: results and discussion of case studies. IEEE Trans Dielectr Electr Insul 22(4):2379–2389CrossRefGoogle Scholar
  115. 115.
    Oommen TV, Prevost TA (2006) Cellulose insulation in oil-filled power transformers: part II maintaining insulation integrity and life. IEEE Electr Insul Mag 22(2):5–14CrossRefGoogle Scholar
  116. 116.
    Gockenbach E et al (2012) Life time prediction of power transformers with condition monitoring. In: 44th International conference on large high voltage electric systems 2012Google Scholar
  117. 117.
    An international survey of failures in large power transformers in service, CIGRE Working Group 05, Electra, no. 88, 21–48 (1983)Google Scholar

Copyright information

© Springer-Verlag Berlin Heidelberg 2017

Authors and Affiliations

  • Md Mominul Islam
    • 1
  • Gareth Lee
    • 1
  • Sujeewa Nilendra Hettiwatte
    • 2
  1. 1.School of Engineering and Information TechnologyMurdoch UniversityMurdochAustralia
  2. 2.School of EngineeringNational School of Business ManagementColomboSri Lanka

Personalised recommendations