Abstract

This paper presents a new intelligent numerical algorithm for analysis of transmission lines disturbance records. The algorithm improves the existing methodologies for fault location, adaptive autoreclosure, detailed disturbance records analysis, and fault data management. It is based on the processing of voltages and currents recorded at both of the line terminals. The algorithm does not require synchronized sampling of data from the line terminals. The proposed algorithm is derived in the spectral domain and is based on the application of the discrete Fourier transform. In the algorithm development, the fault arc is included in the complete fault model. One of advanced algorithm features is ability to determine both the arc and the fault/tower-footing resistance. The algorithm is thoroughly tested using EMTP simulation and real data records.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Sidhu TS (2006). Bibliography of relay literature, 2003 IEEE committee report. IEEE Trans Power Deliv 21: 56–65

    Article  Google Scholar 

  2. Johns AT and Jamali S (1990). Accurate fault location technique for power transmission line. IEE Proc 137: 395–402

    Google Scholar 

  3. Novosel D, Hart DG, Udren E and Garitty J (1992). Unsynchronized two-terminal fault location estimation. IEEE Trans Power Deliv 7(1): 98–107

    Article  Google Scholar 

  4. Girgis AA, Hart DG and Peterson WL (1992). A new fault location technique for two-and three-terminal lines. IEEE Trans Power Deliv 7(1): 98–107

    Article  Google Scholar 

  5. Silveira EG and Pereira C (2007). Transmission line fault location using two-terminal data without time synchronization. IEEE Trans Power Syst 22(1): 498–499

    Article  Google Scholar 

  6. Djurić M and Terzija V (1995). A new approach to the arcing faults detection for autoreclosure in transmission systems. IEEE Trans Power Deliv 10(4): 1793–1798

    Article  Google Scholar 

  7. Lönard D, Simon R, Terzija V (1992) Simulation von Netzmodellen mit zweiseitiger Einspeisung zum Test von Netzschutzeinrichtungen. TB-157/92 Univ. Kaiserslautern (in German)

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Vladimir Terzija.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Radojević, Z., Terzija, V. Intelligent two-port numerical algorithm for transmission lines disturbance records analysis. Electr Eng 90, 323–330 (2008). https://doi.org/10.1007/s00202-007-0088-9

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00202-007-0088-9

Keywords

Navigation