Abstract
Due to more various power disturbances occurring in a power system involving a HVDC link, the turbine generator shafts and/or blades are more prone to damage than in general HVAC systems. In this paper, a new mechanical damper scheme based on participation factor approach is proposed to damp torsional torque and prolong the life of turbine mechanism. Two types of torsional damping couplings, inertia damping coupling and elastic damping coupling, are adopted and examined. The optimal type and the optimal location of the damping coupling will be identified and installed to the turbine generator shaft section. The results demonstrate that the best damper may not be installed at the location with the most onerous vibrations but provides satisfactory damping performance on shafts and blades following severe power disturbances in a HVDC link.
Similar content being viewed by others
References
Hammons TJ, Bremmer JJ (1994) Stressing of turbine-generator-exciter shafts by variable-frequency currents superimposed on DC currents in asynchronous HVDC links and following disturbances at converter stations. IEEE Trans. Energy Conver 9(3):503–513
Hammons TJ, Bremmer JJ (1997) Torque in turbine-generator-exciter shafts due to DC currents in asynchronous HVDC Links. Electric Mach Power Syst 25:87–105
Hammons TJ, Bremner JJ (1995) Analysis of variable-frequency currents superimposed on DC currents in asynchronous HVDC links in stressing turbine-generator-exciter shafts. IEEE Trans Energy Conver 10(1):95–104
Tsai JI, Lin CH, Tsao TP (2004) Assessment of long-term life expenditure for steam turbine shafts due to noncharacteristic subharmonic currents in asynchronous links. IEEE Trans Power Syst 19(1):507–516
Tsai JI, Lin CH, Tsao TP (2003) Long-term fatigue life loss of turbine blades owing to noncharacteristic harmonic currents in asynchronous HVDC links. J Electric Power Syst Res 65(2):135–147
Faried SO, El-Serafi AM (1997) Effect of HVDC converter station faults on turbine-generator shaft torsional torques. IEEE Trans Power Syst 12(2):875–881
Shi W, Iravani MR (1994) Effect of HVDC line faults on transient torsional torques of turbine-generator shafts. IEEE Trans Power Syst 9(3):1457–1462
Lin CH, Tsao TP (2001) Suppress vibrations on turbine blades by high temperature super-conductive fault current limiter. IEE Proc Generation Transm Distrib 148(2):97–103
Gonzalez AJ, Kung GC, Raczkowski C, Taylor CW, Thonn D (1984) Effects of single- and three-pole switching and high-speed reclosing on turbogenerator shafts and blades. IEEE Trans Power App Syst PAS-103(11):3218–3228
Lambrecht D, Kulig T (1982) Torsional performance of turbine generator shafts especially under resonant excitation. IEEE Trans Power App Syst PAS-101:3689–3697
Liang CC (1993) Torsional response of rotor system in steam turbine-generator. Taipower Eng J 538(6):35–52
Power system blockset for use with simulink user’s guide. June 2001
Chyn C, Wu RC, Tsao TP (1996) Torsional fatigue of turbine-generator shafts owing to network faults. IEE Proc Generation Transm Distrib 143(5):479–486
Tsao TP, Lin CH (2000) Long term effect of power system unbalance on the corrosion fatigue life expenditure of low pressure turbine blades. IEE Proc Sci, Meas Technol 147(5):229–236
Placek RJ, Williams RA, Adams SL, Klufas O (1984) Determination of torsional fatigue life of large turbine generator shafts. EPRI EL-3083, Project 1531–1, Final Report
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Tsai, JI. A New Damper Scheme to Restrict Torsional Torques on the Turbine Generator Shafts and Blades near a HVDC Link. Electr Eng 89, 377–387 (2007). https://doi.org/10.1007/s00202-006-0015-5
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00202-006-0015-5