Variations in diagnostic performances of dual-energy X-ray absorptiometry in the northwest of The Netherlands

Abstract

Between-center variation in bone densitometry may influence the frequency of the diagnosis of osteoporosis. To evaluate this problem, dual-energy X-ray absorptiometry (DXA) machines of the medical centers in the northwest of The Netherlands were evaluated. Four phantoms were used to test the 17 DXA machines of 16 participating centers. Each phantom was measured 10 times and the data were analyzed on the corresponding DXA machine using the software delivered by the manufacturer. The analyses were done with the reference population as used in daily practice. There were DXA devices of seven different brands and types, using four different reference populations for the lumbar spine and seven for the hip. The observed differences in bone mineral densities (BMD) were up to 0.20 g/cm2 for the lumbar spine, 0.15 g/cm2 for the femoral neck, and 0.12 g/cm2 for the total hip. The coefficients of variation (CV) of the repeated phantom measurements ranged between 0.3% and 1.3% for the lumbar spine, 1.6% and 4.6% for the femoral neck, and 0.3% and 0.9% for the total hip. The mean female T-scores of 10 phantom measurements differed up to 0.6 SD between the DXA machines for the lumbar spine and up to 0.8 SD for the total hip. Mathematically, replacing a Hologic 2000 DXA machine with a newer type of the same brand (a Hologic 4500) caused a shift in diagnosis from osteoporosis to osteopenia of +1.1% for the lumbar spine and −4.5% for the total hip. When the Hologic 2000 was replaced by a Hologic 4500 with NHANES reference values, the shift from osteoporosis to osteopenia was also +1.1% for the lumbar spine, and −13.4% for the total hip. The clinical impact of the observed differences is difficult to estimate. One may conclude that the differences of the tested DXA devices are partly based on differences in DXA machines, but for the most part on the use of different reference populations. It is recommended to standardize the reference population, although the consequent shift in diagnosis will be confusing for physicians and patients, and adaptation of the reference values on the DXA devices of different brands with different technical qualities and measurement specifications will be difficult.

This is a preview of subscription content, access via your institution.

Fig. 1
Fig. 2
Fig. 3A, B
Fig. 4
Fig. 5
Fig. 6A–C

References

  1. Consensus Development Conference (1991) Diagnosis, prophylaxis and treatment of osteoporosis. Am J Med 90:170–210

    Google Scholar 

  2. Blake GM, Fogelman I (2001) Bone densitometry and the diagnosis of osteoporosis. Semin Nucl Med 31:69–81

    CAS  PubMed  Google Scholar 

  3. Cummings SR, Black DM, Nevitt MC et al (1993) Bone density at various sites for prediction of hip fractures. Lancet 341:72–75

    CAS  PubMed  Google Scholar 

  4. WHO (1994) Assessment of fracture risk and its application to screening for postmenopausal osteoporosis. Technical Report Series, No. 843. World Health Organization, Geneva

  5. Marshall D, Johnell O, Wedel H (1996) Meta-analysis of how well measures of bone mineral of bone mineral density predict occurrence of osteoporotic fractures. Br Med J 312:1254–1259

    CAS  Google Scholar 

  6. Lees B, Garland SW, Walton C, Stevenson JC (1997) Evaluation of the European spine phantom in a multi center trial. Osteoporos Int 7:570–574

    CAS  PubMed  Google Scholar 

  7. Cawte SA, Pearson D, Green DJ, Maslanka WB, Miller CG, Rogers AT (1999) Cross-calibration, precision and patient dose measurements in preparation for clinical trials using dual X-ray absorptiometry of the lumbar spine. Br J Radiol 72:354–362

    CAS  PubMed  Google Scholar 

  8. Chen Z, Maricic M, Lund P, Tesser J, Gluck O (1998) How the new Hologic reference values affect the densitometric diagnosis of osteoporosis. Osteoporos Int 8:423–427

    CAS  PubMed  Google Scholar 

  9. Petley GW, Cotton AM, Murrils AJ, Taylor PA, Cooper C, Cawley MID, Wilkin TJ (1996) Reference ranges of bone mineral density for women in southern England: the impact of local data on the diagnosis of osteoporosis. Br J Radiol 69:655–660

    CAS  PubMed  Google Scholar 

  10. Kalender WA, Felsenberg D, Genant HK, Fischer M, Dequeker J, Reeve J (1995) The European Spine Phantom: a tool for standardization and quality control in spinal bone mineral measurements by DXA and QCT. Eur J Radiol 20:83–92

    Article  CAS  PubMed  Google Scholar 

  11. Looker AC, Wahner HW, Dunn WL, Calvo MS, Harris TB, Heyse SP, Johnston CC Jr, Lindsay RL (1995) Proximal femur bone mineral levels of US adults. Osteoporos Int 5:389–409

    CAS  PubMed  Google Scholar 

  12. Genant H, Grammp S, Gluer C et al (1994) Universal standardization for dual X-ray absorptiometry: patient and phantom cross-calibration results. J Bone Miner Res 9:1503–1514

    CAS  PubMed  Google Scholar 

  13. Pocock NA, Sambrook PN, Nguyen T, Kelly P, Freund J, Eisman JA (1992) Assessment of spinal and femoral bone density by dual X-ray absorptiometry: comparison of Lunar and Hologic instruments. J Bone Miner Res 7:1081–1084

    CAS  PubMed  Google Scholar 

  14. Barthe N, Braillon P, Ducassou, Basse-Cathilinat (1997) Comparison of two DXA systems (QDR 1000 and QDR 4500/A). Br J Radiol 70:728–739

    Google Scholar 

  15. Lu Y, Fuerst T, Hui S, Genant HK (2001) Standardization of bone mineral density at femoral neck, trochanter and Ward’s triangle. Osteoporos Int 12:438–444

    CAS  PubMed  Google Scholar 

  16. Simmons A. Barrington SF, O’Doherty MJ, Coakley AJ (1995) DEXA normal reference ranges on the assesment of bone density. Br J Radiol 68:809

    Google Scholar 

  17. Ahmed AIH, Blake GM, Rymer JM, Fogelman I (1997) Screening for osteopenia and osteoporosis: do the accepted normal ranges lead to overdiagnosis? Osteoporos Int 7:432–438

    Article  CAS  PubMed  Google Scholar 

  18. Laskey MA, Crisp AJ, Cole TJ, Compston JE (1992) Comparison of the effect of different reference data in Lunar DPX and Hologic QDR 1000 dual X-ray absorptiometers. Br J Radiol 65:1124–1129

    CAS  PubMed  Google Scholar 

Download references

Acknowledgements

The authors thank all radiologists, nuclear medicine specialists, internists, and technicians in the centers for their collaboration.

Author information

Affiliations

Authors

Consortia

Corresponding author

Correspondence to Paul Lips.

Appendix: Members of the Densitometry Study Group

Appendix: Members of the Densitometry Study Group

P.R. Algra, Medisch Centrum Alkmaar, Alkmaar; R.O. Boer, Westfries Gasthuis, Hoorn; C.B. Brouwer, Onze Lieve Vrouwe Gasthuis, Amsterdam; R.H. Cohen, Ziekenhuis Amstelveen, Amstelveen; B.L.F. van Eck, Academic Medical Centre, Amsterdam; A. Heiboer and W.F. Lems, Slotervaart Ziekenhuis, Amsterdam; Z. de Jong, Leids Universitair Medisch Centrum, Leiden; S.P.M. Mali, St. Gemini Ziekenhuis, Den Helder; P.A.R. Rombout, Spaarne Ziekenhuis, Haarlem; F.G. Scholten, Ziekenhuis Gooi Noord, Blaricum; J.M. Schut, Ziekenhuis Hilversum, Hilversum; J. Treurniet, Ziekenhuis Leyenburg, Den Haag; N.K. Valk, Rode Kruis Ziekenhuis, Beverwijk; L.H.L. Winter, Diagnostisch Centrum Amsterdam, Amsterdam; H.J. Wieringa, Jan van Bremen Instituut, Amsterdam.

Rights and permissions

Reprints and Permissions

About this article

Cite this article

Staal, K.P., Roos, J.C., Manoliu, R.A. et al. Variations in diagnostic performances of dual-energy X-ray absorptiometry in the northwest of The Netherlands. Osteoporos Int 15, 335–344 (2004). https://doi.org/10.1007/s00198-003-1541-x

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00198-003-1541-x

Keywords

  • Between-center variation
  • DXA
  • Osteoporosis
  • Phantom measurements