Abstract
Introduction and hypothesis
We present three cases of transvaginal removal of mesh exposure involving the bladder, including patient follow-up. Mesh exposure occurred secondary to placement of transvaginal mesh for management of pelvic organ prolapse.
Methods
A pure transvaginal technique was performed to remove mesh exposure involving the bladder. Patient follow-ups were carefully recorded.
Results
All operative steps were completed transvaginally. The duration of follow-up for the three cases was 6, 11, and 19 months. One patient experienced recurrence of mesh exposure during follow-up. The other two patients were symptom-free after surgery. There were no major postoperative complications and no recurrence of cystocele.
Conclusions
Transvaginal removal of mesh exposure involving the bladder is feasible. The pure transvaginal approach is applicable to various conditions with good outcomes, yet it cannot guarantee that exposure of residual fibers within the bladder will not recur.
References
Firoozi F, Goldman HB (2010) Transvaginal excision of mesh erosion involving the bladder after mesh placement using a prolapse kit: a novel technique. Urology 75(1):203–206. doi:10.1016/j.urology.2009.08.052
Haylen BT, Freeman RM, Swift SE et al (2011) An International Urogynecological Association (IUGA)/International Continence Society (ICS) joint terminology and classification of the complications related directly to the insertion of prostheses (meshes, implants, tapes) & grafts in female pelvic floor surgery. Int Urogynecol J 22(1):3–15. doi:10.1007/s00192-010-1324-9
Firoozi F, Goldman H (2013) Pure transvaginal excision of mesh erosion involving the bladder. Int Urogynecol J 24(6):925–926. doi:10.1007/s00192-013-2082-2
Bieniek JM, Holste TL, Platte RO et al (2012) Cystoscopic removal of intravesical synthetic mesh extrusion with the aid of Endoloop sutures and endoscopic scissors. Int Urogynecol J 23(8):1137–1139. doi:10.1007/s00192-012-1668-4
Doumouchtsis SK, Lee FY, Bramwell D et al (2011) Evaluation of holmium laser for managing mesh/suture complications of continence surgery. BJU Int 108(9):1472–1478. doi:10.1111/j.1464-410X.2010.10012.x
Consent
Written informed consent was obtained from the patient for publication of this case report and any accompanying images.
Conflicts of interest
None.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Yang, TX., Dai, Y. & Shen, H. Transvaginal removal of mesh exposure involving the bladder. Int Urogynecol J 25, 847–849 (2014). https://doi.org/10.1007/s00192-013-2251-3
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00192-013-2251-3