Skip to main content

Advertisement

Log in

A randomized controlled trial of the NEAT expandable tip continence device

  • Original Article
  • Published:
International Urogynecology Journal Aims and scope Submit manuscript

Abstract

Urethral devices are one conservative management option for stress and mixed urinary incontinence, but there is little published data about their use. The aims of this study were to assess the safety and efficacy of a new urethral device (NEAT) and compare it with the Reliance Insert. The ease of use of both devices was then evaluated. Twenty-four women with mixed or stress urinary incontinence, patients at our tertiary care urogynecology unit and who met the inclusion and exclusion criteria, were enrolled in the study. Study subjects were blinded and randomly assigned to a device group. Device efficacy was assessed by pad weighing at 0 and 4 months. Success was defined as a 50% or greater reduction in urine loss using the formula 100[(pad weight without device −pad weight with device)/pad weight with device]. Safety was evaluated using urinalysis and urine cultures. Ease of use assessment scales were also completed. Eleven patients were randomized to the Reliance Insert and 13 to the NEAT device. There were no significant differences between the two groups in age, height, weight, duration of incontinence, pad weight, leakage score, parity or quality of life score. Based on the pad weight success formula, there was no significant difference in device success between the two groups at 4 months. Women who were postmenopausal had a trend towards a higher level of success in reduction of their pad weight. Previous treatment, diagnosis and hormone replacement therapy all had no relationship to device success. Leakage score data showed that subjects had a significant decrease in urine leakage when using either device. There was no statistically significant difference in ease of use between the two devices. Adverse symptoms most commonly noted were awareness of the device (62.5%), urgency (29.2%), and urethral discomfort or pain (20.8%). One urinary tract infection (UTI) was observed. The most common finding on urinalysis was trace hematuria (15.8%). Our conclusions are that the NEAT device appears to be at least as effective and safe as the Reliance Insert. Both devices are effective at decreasing urine leakage in patients with stress or mixed urinary incontinence. The risk of UTI is low, but these devices may cause trace hematuria.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1.
Fig. 2.
Fig. 3.
Fig. 4.

Similar content being viewed by others

Abbreviations

UTI:

urinary tract infection

References

  1. Angus Reid Group Inc (1997) Population survey: urinary incontinence in the Canadian adult population. Released through Canadian Continence Foundation. Oct 1997

    Google Scholar 

  2. Diokno A (1996) The benefits of conservative management for stress urinary incontinence. Contemp Urol 8:36–41

    Google Scholar 

  3. Sand PK, Staskin D, Miller J et al (1999) Effect of a urinary control insert on quality of life in incontinent women. Int Urogynecol J 10:100–105

    CAS  Google Scholar 

  4. Miller JL, Bavendam T (1996) Treatment with the reliance urinary control insert: one-year experience. J Endourol 10:287–292

    CAS  PubMed  Google Scholar 

Download references

Acknowledgments

The authors would like to thank Craig Hiltz for performing the statistical analyses for this study.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to H. Robinson.

Additional information

Editorial Comment: Devices for treatment of urinary incontinence must be safe and effective. This small study was originally part of a much larger study that could address safety and efficacy. Although the number of patients presented in this report is small, the device may be of interest for readers of this journal.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Robinson, H., Schulz, J., Flood, C. et al. A randomized controlled trial of the NEAT expandable tip continence device. Int Urogynecol J 14, 199–203 (2003). https://doi.org/10.1007/s00192-002-1021-4

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00192-002-1021-4

Keywords

Navigation