Skip to main content

Advertisement

Log in

Study on double-sided impedance matching of spherical focusing transducer in ultrasonic abrasive flow polishing system

  • ORIGINAL ARTICLE
  • Published:
The International Journal of Advanced Manufacturing Technology Aims and scope Submit manuscript

Abstract

The impedance matching of spherical focused ultrasonic transducer is one of the primary factors affecting the energy utilization efficiency in focused ultrasonic flow polishing system. To realize the efficient utilization of the vibration energy of the transducer, the front matching layer structure is design to achieve the impedance matching of the transducer and the abrasive flow liquid, thereby improving the transmittance of the transducer vibration energy in the liquid, and the back-matching layer structure is used to reflect the radiated vibration energy on the back of the transducer to reduce dissipation of radiated vibration energy on the back of the transducer. Based on the acoustic impedance matching theory and Kirchhoff’s theory, the influence of the front and back impedance matching structure of spherical focused ultrasonic transducer on the focal point sound pressure is studied theoretically, and experimentally, a novel impedance matching structure for spherical focused ultrasonic transducer is proposed. The experimental results showed that the focal point sound pressure was increased by 72.03% compared with that of the traditional structure.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8
Fig. 9
Fig. 10
Fig. 11
Fig. 12
Fig. 13
Fig. 14
Fig. 15
Fig. 16
Fig. 17
Fig. 18
Fig. 19

Similar content being viewed by others

References

  1. Zhou Y, Ji X, Niu JM, Sun TT, Qian ZX, Li YH, Yuan JJ, Fan Q, Huang QW, Bai JF, Wang YD (2021) Ultrasound-guided high-intensity focused ultrasound for devascularization of uterine fibroid: a feasibility study. Ultrasound Med Biol 47:2622–2635

    Article  Google Scholar 

  2. Rachidi E, Delaunois D (2019) Effectiveness of phased array focused ultrasound and active infrared thermography methods as a nondestructive testing of Ni-WC coating adhesion. Nondestruct Test Eval 34:205–220

    Article  Google Scholar 

  3. Cao HQ, Guo SF, Zhang SX, Xie YF, Feng W (2021) Ray tracing method for ultrasonic array imaging of CFRP corner part using homogenization method. NDT E Int 122:102493

  4. Li H, Ren K, Yin Z, Dai CW, Wang ZW, Wei L, Wei D (2021) Review of ultrasonic vibration-assisted abrasive flow polishing technology. J Mech Eng 57:233–253

    Google Scholar 

  5. Wu Y, Fei CL, Yang XY, Chen J, Zhou QF (2019) Research status and development of focused ultrasonic transducers. Piezoelectrics Acoustooptic 41:904–909

    Google Scholar 

  6. Toda M, Thompson M (2012) Detailed investigations of polymer/metal multilayer matching layer and backing absorber structures for wideband ultrasonic transducers. IEEE T Ultrason Ferroelectr 59:231–242

    Article  Google Scholar 

  7. Fu L, Gao YL, Gao JM (2019) Study on the influence of backing on radiation efficiency of ultrasonic transducer. Acta Acustica 44:251–257

    Google Scholar 

  8. Zhang JY, Yin GJ, Guo JZ (2019) Study on the influence of backing on radiation efficiency of ultrasonic transducer. 2019 Shanghai-Xi 'an Acoustical Society 6th Acoustics Academic Exchange Conference Proceedings 4

  9. Liu K, Wang G, Guo JZ (2019) Optimum design of matching layer of concave spherical ultrasonic focusing transducer. 2019 National Acoustics Conference. Shenzhen, Guangdong, China 2

  10. Cheng JZ, Zhou YL, Mao YX, Zhang DJ (2008) Sound fields in a concave spherical transducer with linear superposition of Rayleigh integrals. Chin J Comput Phys 4:493–498

    Google Scholar 

  11. Wang ZW, Li H, Wang BF, Xie O, Ren K (2019) Numerical simulation and measurement of acoustic pressure of focused ultrasonic vibration spherical shell. J Mech Electr Eng 36:949–953

    Google Scholar 

  12. Tan B, Chen Y, Li PC, Huang R, Chen H (2012) Study on the acoustic energy characteristic of PZT based backing structure on thickness vibration mode. Chinese J Appl Mech 29:32–37

    Google Scholar 

  13. Rathod VT (2020) A review of acoustic impedance matching techniques for piezoelectric sensors and transducers. Sensors 20:1–65

    Article  Google Scholar 

  14. Zhang JC, Yang SP, Hao LJ, Gu XH (2018) A study on sound pressure transmission coefficient of elastic wave propagation to acoustic emission sensors. J Vib Shock 37:153–158

    Google Scholar 

  15. He YB, Gao TW, Guo A, Qiao TX, He CX, Wang GS, Liu XN, Yang XT (2021) Lubricant film thickness measurement based on ultrasonic reflection coefficient phase shift. Tribology 41:1–8

    Google Scholar 

Download references

Funding

This work was supported by the National Natural Science Foundation of China [51905363], the Natural Science Foundation of Jiangsu Province [BK20190940], the and Master Research Startup Project of Suzhou University of Science and Technology.

Author information

Authors and Affiliations

Authors

Contributions

Li Wei: conceptualization, investigation, methodology, and writing original draft preparation. Hua Li: investigation and writing original draft preparation. Dong Wei: validation.

Corresponding author

Correspondence to Hua Li.

Ethics declarations

Ethics approval

Not applicable.

Consent for publication

All authors have read and agreed to the published version of the manuscript.

Competing interests

The authors declare no competing interests.

Additional information

Publisher's note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Wei, L., Li, H. & Wei, D. Study on double-sided impedance matching of spherical focusing transducer in ultrasonic abrasive flow polishing system. Int J Adv Manuf Technol 120, 3287–3297 (2022). https://doi.org/10.1007/s00170-022-08972-0

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00170-022-08972-0

Keywords

Navigation