Skip to main content
Log in

Effect of pulse current in manufacturing of cardiovascular stent using EDM die-sinking

  • ORIGINAL ARTICLE
  • Published:
The International Journal of Advanced Manufacturing Technology Aims and scope Submit manuscript

This article has been updated

Abstract

This paper proves that die-sinking electrical discharge machining (EDM) is an alternative and attractive manufacturing method of producing cardiovascular stent. This study investigates the effect of pulse currents on the material removal rate (MRR), the surface of EDM, and the upper surface of the strut stent. The observed surface characteristics of the strut were surface roughness, recast layer, and the diameter of the crater. The recast layer and crater were analyzed by an optical microscope, and the surface roughness was measured by a surface profilometer. The pulse currents which were used in the manufacturing of stent by die-sinking EDM were 1.5 A/45 μs, 3.0 A/90 μs, 4.5 A/120 μs, and 6 A/150 μs. The experiment shows that the stent is successfully manufactured from minitube AISI 316L by die-sinking EDM. The diameter, length, and thickness of the stent are 4 mm, 20 mm, and 0.3 mm, respectively. The results show that increasing of pulse current will cause the increase of MRR, the thickness of recast layer, the surface roughness, and the crater diameter. The MRR, thickness of the recast layer, surface roughness, and crater diameter are also influenced by the pulse on time. The EDM surface roughness, the average thickness of recast layer, and the diameter of crater are in the range of 3.49–9.53 μm, 17.6–97 μm, and 75.84–276.5 μm, respectively, and the upper surface roughness of the strut is 0.5534 μm. The best quality of the strut is generated from the pulse current 1.5 A/45 μs.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8
Fig. 9

Similar content being viewed by others

Data availability

(Not applicable)

Change history

  • 02 February 2021

    Springer Nature’s version of this paper was updated to present the correct affiliation 1, Sumetra should be changed Sumatera.

Abbreviations

E e :

energy spark

U e :

voltage

I e :

pulse current

t e :

discharge time

References

  1. Suryawan D, Suyitno (2017) Design and modeling balloon-expandable coronary stent for manufacturability. IOP Conf Mater Sci Eng 172:1–7

    Google Scholar 

  2. Saraf AR, Yadaf AP (2018) Fundamental of bare metal stent. In: Functionalized Cardiovascular Stent. Woodhead Publishing, America

    Google Scholar 

  3. Ratner BR (2004) Biomaterial science: an introduction to materials in medicine. Elsevier Academic Press, America

    Google Scholar 

  4. Gourlay T, Black RA (2010) Biomaterials and devices for the circulatory system, 1st edn. Woodhead Publishing

  5. Moravej M, Mantovani D (2011) Biodegradable metals for cardiovascular stent application: interests and new opportunities. Int J Mol Sci 12:4250–4270

    Article  Google Scholar 

  6. Bowen PK, Shearier ER, Zhao S, Guillory RJ II, Zhao F, Goldman J, Drelich JW (2016) Biodegradable metals for cardiovascular stents: from clinical concerns to recent Zn-alloys. Adv Healthc Mater 2016(5):1121–1140

    Article  Google Scholar 

  7. Zheng H, Xu Y, Xu X, Wang Z, Cai J (2017) Metallic biomaterials:new directions and technologies. Wiley-VCH Verleg GmbH, Germany

    Book  Google Scholar 

  8. Hanada K, Matsuzaki K, Huang X, Chino Y (2013) Fabrication of Mg alloy tubes for biodegradable stent application. Mater Sci Eng 50:4746–4750

    Article  Google Scholar 

  9. Hermawan H, Mantovani D (2013) Process of prototyping coronary stents from biodegradable Fe – Mn alloys. Acta Biomater 9:8585–8592

    Article  Google Scholar 

  10. Catalano G, Gokhan A, Furlan V, Previteli B (2017) Use of sheet material for rapid prototyping of cardiovascular stents. in Procedia Engineering: 17th International Confrence on Sheet Metal SHEMET 17, 183:194–199

  11. Takahata K, Gianchandani YB (2004) A planar approach for manufacturing cardiac stents : design , fabrication , and mechanical evaluation. J Microelectromech Syst 13:933–999

    Article  Google Scholar 

  12. Zou Q, Xue W, Lin J, Fu Y (2016) Mechanical characteristics of novel polyester / NiTi wires braided composite stent for the medical application. Results Phys 6:440–446

    Article  Google Scholar 

  13. Mahardika M, Tsujimoto T, Mitsui K (2008) A new method for monitoring micro-electric discharge machining processes. Int J Mach Tools Manuf 48:446–458

    Article  Google Scholar 

  14. Shabgard MR, Seyedzavvar M, Oliaei SNB (2011) Influence of input parameters on characteristics of EDM process. J Mech Eng 57:689–696

    Article  Google Scholar 

  15. Randhawa KS (2015) Effect of process parameters on surface roughness and material removal rate in EDM. Int J Res Mech Eng Technol 5:78–81

    Google Scholar 

  16. Klocke F, Schneider S, Ehle L, Meyer H, Hensgen L, Klink A (2016) Investigations on surface integrity of heat treated 42CrMo4 (AISI 4140) processed by sinking EDM. 18th CIRP Confrence Electro Phys Chamical Mach (ISEM XVIII). 42: 580–585

  17. Rizvi SAH, Agarwal S (2016) An investigation on surface integrity in EDM process with a cooper tungsten electrode. in 18th CIRP Confrence on Electro Physical and Chamical Machining (ISEM XVIII). 42:612–617.

  18. http://www.camtechnologiesinc.com/wire-edm-cutting-vs-laser-cutters/ (accessed 2020.10.25)

  19. Oberg E, Jones FD, Horton HL, Ryffel HF (2000) Electrical Discharge Machining. Industrial Press Inc., New York

    Google Scholar 

  20. Kalpakjian S, Schmid SR (2009) Manufacturing Engineering and Technology. Person Longman Press, America

    Google Scholar 

  21. Klocke F, Schwade M, Klink A (2013) Veselovec, D.: Analysis of material removal rate and electrode wear in sinking EDM roughing strategies using different graphite grades. Procedia CIRP 6:163–167

    Article  Google Scholar 

  22. Khan AA, Adesta EYT, Ali MY (2010) Influence of process parameters on surface integrity during EDM of mild steel. Proceedings of the 22nd United Kingdom-Malaysia Engineering Conference. CE-11:1–7

  23. Goswami A, Kumar J (2014) Investigation of surface integrity , material removal rate and wire wear ratio for WEDM of Nimonic 80A alloy using GRA and Taguchi method. Eng Sci Technol Int J 17:173–184

    Google Scholar 

  24. Das AK, Kumar P, Sethi A, Singh PK, Hussain M (2016) Influence of Process parameters on the surface integrity of micro-holes of SS304 obtained by micro-EDM. Braz Soc Mech Sci Eng 38:2029–2037

    Article  Google Scholar 

  25. Antar M, Hayward P, Dunleavy J, Butler-Smith P (2018) Surface integrity evaluation of modified EDM surface structure. 19th CIRP Confr on Electro Phys Chem Machin. 68:308–312

  26. Petropoulos GP, Vaxevanidis NM, Radovanovi M (2009) Morphological - functional aspects of electro-discharge machined surface textures. J Mech Eng 55:95–103

    Google Scholar 

  27. Arooj S, Shah M, Sadiq S, Jaffery SHI, Khushnood S (2014) Effect of current in the EDM machining of aluminum 6061 T6 and its effect on the surface morphology. Arab J Sci Eng 39:4187–4199

    Article  Google Scholar 

  28. Pujari SR, Koona R, Beela S (2018) Surface integrity of wire EDMed aluminum alloy: a comprehensive experimental investigation. J King Saud Univ - Eng Sci 30:368–376

    Google Scholar 

  29. Sonawane SA, Kulkarni ML (2018) Optimization of machining parameters of WEDM for Nimonic-75 alloy using principal component analysis integrated with Taguchi method. J King Saud Univ - Eng Sci 30:250–258

    Article  Google Scholar 

  30. Gotimirovic M, Kovac P, Sekulic M, Skoric B (2010) Influence of discharge energy on machining characteristics in EDM. J Mech Sci Technol 26:173–179

    Article  Google Scholar 

  31. Gocke C, Grabow N, Schultze C, Sternberg K, Schmidt W, Schmitz KP (2008) Coating homogeneity in the manufacture of drug-eluting stents. IFMBE Proc 22:2240–2243

    Article  Google Scholar 

Download references

Funding

This work is supported by the Centre for Innovation of Medical Equipment and Devices (CIMEDs), Department of Mechanical and Industrial Engineering, Faculty of Engineering, Gadjah Mada University, Indonesia.

Author information

Authors and Affiliations

Authors

Contributions

All authors have participated in (a) conception and design, or analysis and interpretation of the data; (b) drafting the article or revising it critically for important intellectual content; and (c) approval of the final version.

Corresponding authors

Correspondence to Eko Pujiyulianto or Suyitno.

Ethics declarations

Conflict of interest

The authors declare that they have no conflict of interest.

Ethics approval

(Not applicable)

Consent to participate

(Not applicable)

Consent for publication

(Not applicable)

Code availability

(Not applicable)

Additional information

Publisher’s note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Pujiyulianto, E., Suyitno Effect of pulse current in manufacturing of cardiovascular stent using EDM die-sinking. Int J Adv Manuf Technol 112, 3031–3039 (2021). https://doi.org/10.1007/s00170-020-06484-3

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00170-020-06484-3

Keywords

Navigation