Restoration of normal knee joint function is the goal of total knee replacement (TKR) surgery. However, due to the various size and shapes of human knee joint of every individual, a ready-made commercial implant may not conform to a patient anatomy for meeting specific patient needs. Since mismatched implants often cause a severe balancing problem and a short-term durability, customizing an implant is a unique solution for patients with a deformity or an abnormal anatomy. This paper presents a methodology that creates a customized knee implant model by extracting typical 3-dimensional (3D) geometrical parameters of the knee. All of the derived parameters are directly used to define the geometry of implant. Software system was developed to extract knee parameters and determine implants for individual. Surgeons are also able to simulate the whole process of surgery with the system, so that they know what the custom-made implant should be for the patient prior to surgery. The feasibility and verification of a custom-made knee implant is described with case study. It indicates that the proposed system is applicable in the early stage of implant design process.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Werner A, Lechniak Z, Skalski K, Kedzior K (2000) Design and manufacture of anatomical hip joint endostems using CAD/CAM systems. J Mater Process Technol 107:181–186

    Article  Google Scholar 

  2. Götzea C, Vieth V, Meier N, Böttner F, Steinbeck J, Hackenberg L (2005) CT-based accuracy of implanting custom-made endoprostheses. Clin Biomech 20(8):856–862

    Article  Google Scholar 

  3. Ruyu M, Wendong X, Dongmei W, Kerong D, Chengtao W (2005) Design and manufacture of custom hip prostheses based on standard X-ray films. Int J Adv Manuf Technol 27:70–74

    Article  Google Scholar 

  4. Jun Y, Choi K (2009) Design of patient-specific hip implants based on the 3D geometry of the human femur. Adv Eng Softw.; doi:10.1016/j.advengsoft.2009.10.016.

  5. Barrett WP (2006) The need for gender-specific prostheses in TKA: does size make a difference? Orthopedics 29:S53–S55

    Google Scholar 

  6. Greene KA (2007) Gender-specific design in total knee arthroplasty. J Arthroplasty 22:27–31

    Article  Google Scholar 

  7. Conley S, Rosenberg A, Crowninshield R (2007) The female knee: anatomic variations. J Am Acad Orthop Surg 15(Suppl 1):S31–S36

    Google Scholar 

  8. Mahfouz MR, Merkl BC, Fatah EA, Booth R, Argenson JN (2007) Automatic methods for characterization of sexual dimorphism of adult femora: distal femur. Comput Meth Biomech Biomed Eng 10:447–456

    Article  Google Scholar 

  9. Klatt BA, Goyal N, Austin MS, Hozack WJ (2008) Custom-fit total knee arthroplasty (OtisKnee) results in malalignment. J Arthroplast 23(1):26–29

    Article  Google Scholar 

  10. Liska WD, Marcellin-little DJ, Eskelinen EV, Sidebotham CG, Harrysson OLA, Hielm-björkman AK (2007) Custom total knee replacement in a dog with femoral condylar bone loss. Vet Surg 36:293–301

    Article  Google Scholar 

  11. Feng Z, Ziv I, Rho J (1996) The accuracy of computed tomography-based linear measurements of human femora and titanium stem. Invest Radiol 31(6):333–337

    Article  Google Scholar 

  12. Laine HJ, Pajamaki KJ, Moilanen T, Lehto MU (2001) The femoral canal fill of two different cementless stem designs. The accuracy of radiographs compared to computed tomographic scanning. Int Orthop 25(4):209–213

    Article  Google Scholar 

  13. Park S, Yoon YS, Kim LH, Lee SH, Han M (2007) Virtual knee joint replacement surgery system, GMAI 2007: Proceedings of the Geometric Modeling and Imaging; 2007 July 4–6; Zurich, Switzerland. p. 79–84.

  14. Iesaka K, Tsumura H, Sonoda H, Sawatari T, Takasita M, Torisu T (2002) The effects of tibial component inclination on bone stress after unicompartmental knee arthroplasty. J Biomech 35:969–974

    Article  Google Scholar 

  15. Ahn SJ (2004) Least squares orthogonal distance fitting of curves and surfaces in space [PhD dissertation]: the University of Stuttgart.

  16. http://www.rapidform.com/.

  17. Wehmoller M, Warnke PH, Zilian C, Eufinger H (2005) Implant design and production—a new approach by selective laser melting. CARS 2005: Computer Assisted Radiology and Surgery; 2005 June 22–25. Elsevier, Berlin, pp 690–695

    Google Scholar 

  18. Sathasivam S, Walker PS, Pinder IM, Cannon SR, Briggs TWR (1999) Custom constrained condylar total knees using CAD-CAM. Knee 6:49–53

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Yongtae Jun.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Jun, Y. Morphological analysis of the human knee joint for creating custom-made implant models. Int J Adv Manuf Technol 52, 841–853 (2011). https://doi.org/10.1007/s00170-010-2785-1

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00170-010-2785-1

Keywords

Navigation