Skip to main content

Advertisement

Log in

The effect of anterior cruciate ligament graft orientation on rotational knee kinematics

  • Knee
  • Published:
Knee Surgery, Sports Traumatology, Arthroscopy Aims and scope

Abstract

Purpose

To determine whether coronal graft orientation and tunnel placement for single-bundle anterior cruciate ligament (ACL) reconstruction is associated with tibial rotation excursion during functional activities.

Methods

Eighty-four patients who had undergone ACL reconstruction over a ten-year time span had tibial rotation measured during level walking, using a three-dimensional motion analysis system. Fifty-two patients also had measures taken during the more dynamic task of single-limb landing. During the 10-year period, the position of the graft was deliberately changed from a vertical to more horizontal orientation in the coronal plane. Post-operative radiographs were analysed for the coronal graft orientation and femoral and tibial tunnel positions. Radiographic measurements of graft orientation and tunnel position were then correlated with the amount of tibial rotational excursion recorded during the walking and landing tasks.

Results

For the single-limb landing task, a significant positive correlation was observed between the coronal graft angle and rotational excursion (R = 0.35, R 2 = 0.12, p = 0.01). This indicated greater rotational excursion was associated with vertical graft orientation, but only explained 12 % of the variance. No correlations were found between coronal graft angle and tibial rotation during level walking.

Conclusions

These findings support the notion that ACL graft orientation may play a role in rotational kinematics of the ACL-reconstructed knee, particularly during higher impact activities.

Level of evidence

IV.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4

Similar content being viewed by others

References

  1. Andriacchi TP, Briant PL, Bevill SL, Koo S (2006) Rotational changes at the knee after ACL injury cause cartilage thinning. Clin Orthop Relat Res 442:39–44

    Article  PubMed  Google Scholar 

  2. Davis RB, Ounpuu S, Tyburski D, Gage JR (1991) A gait analysis data collection and reduction technique. Hum Mov Sci 10:575–587

    Article  Google Scholar 

  3. Gao B, Zheng NN (2010) Alterations in three-dimensional joint kinematics of anterior cruciate ligament-deficient and -reconstructed knees during walking. Clin Biomech 25(3):222–229

    Article  Google Scholar 

  4. Georgoulis AD, Ristanis S, Chouliaras V, Moraiti C, Stergiou N (2007) Tibial rotation is not restored after ACL reconstruction with a hamstring graft. Clin Orthop Relat Res 454:89–94

    Article  PubMed  Google Scholar 

  5. Hui C, Salmon LJ, Kok A, Maeno S, Linklater J, Pinczewski LA (2011) Fifteen-year outcome of endoscopic anterior cruciate ligament reconstruction with patellar tendon autograft for “isolated” anterior cruciate ligament tear. Am J Sports Med 39(1):89–98

    Article  PubMed  Google Scholar 

  6. Irrgang JJ, Anderson AF, Boland AL, Harner CD, Kurosaka M, Neyret P, Richmond JC, Shelbourne KD (2001) Development and validation of the international knee documentation committee subjective knee form. Am J Sports Med 29(5):600–613

    PubMed  CAS  Google Scholar 

  7. Jepsen C, Lundberg-Jensen A, Faunoe P (2007) Does the position of the femoral tunnel affect the laxity or clinical outcome of the anterior cruciate ligament-reconstructed knee? A clinical, prospective, randomized, double-blind study. Arthroscopy 23(12):1326–1333

    Article  PubMed  Google Scholar 

  8. Kadaba M, Ramakrishnan H, Wootten M, Gainey J, Gorton G, Cochran G (1989) Repeatability of kinematic, kinetic, and electromyographic data in normal adult gait. J Orthop Res 7(6):849–860

    Article  PubMed  CAS  Google Scholar 

  9. Kadaba MP, Ramakrishnan HK, Wootten ME (1990) Measurement of lower extremity kinematics during level walking. J Orthop Res 8(3):383–392

    Article  PubMed  CAS  Google Scholar 

  10. Lee M, Seong S, Lee S, Chang C, Park Y, Jo H, Kim C (2007) Vertical femoral tunnel placement results in rotational knee laxity after anterior cruciate ligament reconstruction. Arthroscopy 23(7):771–778

    Article  PubMed  Google Scholar 

  11. Loh JC, Fukuda Y, Tsuda E, Steadman RJ, Fu FH, Woo SL (2003) Knee stability and graft function following anterior cruciate ligament reconstruction: comparison between 11 o’clock and 10 o’clock femoral tunnel placement. Arthroscopy 19(3):297–304

    Article  PubMed  Google Scholar 

  12. Misonoo G, Kanamori A, Ida H, Miyakawa S, Ochiai N (2012) Evaluation of tibial rotational stability of single-bundle versus anatomical double-bundle anterior cruciate ligament reconstruction during a high-demand activity—A quasi-randomized trial. Knee 19(2):87–93

    Article  PubMed  Google Scholar 

  13. Pinczewski LA, Salmon LJ, Jackson WF, von Bormann RB, Haslam PG, Tashiro S (2008) Radiological landmarks for placement of the tunnels in single-bundle reconstruction of the anterior cruciate ligament. J Bone Joint Surg Br 90(2):172–179

    PubMed  CAS  Google Scholar 

  14. Ristanis S, Giakas G, Papageorgiou CD, Moraiti T, Stergiou N, Georgoulis AD (2003) The effects of anterior cruciate ligament reconstruction on tibial rotation during pivoting after descending stairs. Knee Surg Sports Traumatol Arthrosc 11(6):360–365

    Article  PubMed  CAS  Google Scholar 

  15. Ristanis S, Stergiou N, Patras K, Tsepis E, Moraiti C, Georgoulis AD (2006) Follow-up evaluation 2 years after ACL reconstruction with bone-patellar tendon-bone graft shows that excessive tibial rotation persists. Clin J Sport Med 16(2):111–116

    Article  PubMed  Google Scholar 

  16. Ristanis S, Stergiou N, Patras K, Vasiliadis HS, Giakas G, Georgoulis AD (2005) Excessive tibial rotation during high-demand activities is not restored by anterior cruciate ligament reconstruction. Arthroscopy 21(11):1323–1329

    Article  PubMed  Google Scholar 

  17. Ristanis S, Stergiou N, Siarava E, Ntoulia A, Mitsionis G, Georgoulis AD (2009) Effect of femoral tunnel placement for reconstruction of the anterior cruciate ligament on tibial rotation. J Bone Joint Surg Am 91(9):2151–2158

    Article  PubMed  Google Scholar 

  18. Scanlan SF, Blazek K, Chaudhari AM, Safran MR, Andriacchi TP (2009) Graft orientation influences the knee flexion moment during walking in patients with anterior cruciate ligament reconstruction. Am J Sports Med 37(11):2173–2178

    Article  PubMed  Google Scholar 

  19. Scanlan SF, Chaudhari AM, Dyrby CO, Andriacchi TP (2010) Differences in tibial rotation during walking in ACL reconstructed and healthy contralateral knees. J Biomech 43(9):1817–1822

    Article  PubMed  Google Scholar 

  20. Scopp JM, Jasper LE, Belkoff SM, Moorman CTr (2004) The effect of oblique femoral tunnel placement on rotational constraint of the knee reconstructed using patellar tendon autografts. Arthroscopy 20:294–299

    Article  PubMed  Google Scholar 

  21. Stergiou N, Ristanis S, Moraiti C, Georgoulis A (2007) Tibial rotation in anterior cruciate ligament (ACL)-deficient and ACL-reconstructed knees: a theoretical proposition for the development of osteoarthritis. Sports Med 37:601–613

    Article  PubMed  Google Scholar 

  22. Tsarouhas A, Iosifidis M, Kotzamitelos D, Spyropoulos G, Tsatalas T, Giakas G (2010) Three-dimensional kinematic and kinetic analysis of knee rotational stability after single- and double-bundle anterior cruciate ligament reconstruction. Arthroscopy 26(7):885–893

    Article  PubMed  Google Scholar 

  23. Webster KE, Feller JA (2012) Tibial rotation in anterior cruciate ligament reconstructed knees during single limb hop and drop landings. Clin Biomech 27(5):475–479

    Article  Google Scholar 

  24. Webster KE, Palazzolo SE, McClelland JA, Feller JA (2012) Tibial rotation during pivoting in anterior cruciate ligament reconstructed knees using a single bundle technique. Clin Biomech 27(5):480–484

    Article  Google Scholar 

  25. Webster KE, Feller JA (2011) Alterations in joint kinematics during walking following hamstring and patellar tendon anterior cruciate ligament reconstruction surgery. Clin Biomech 26(2):175–185

    Article  Google Scholar 

  26. Webster KE, Gonzalez-Adrio R, Feller JA (2004) Dynamic joint loading following hamstring and patellar tendon anterior cruciate ligament reconstruction. Knee Surg Sports Traumatol Arthrosc 12(1):15–21

    Article  PubMed  Google Scholar 

  27. Webster KE, McClelland JA, Wittwer JE, Tecklenburg K, Feller JA (2010) Three dimensional motion analysis of within and between day repeatability of tibial rotation during pivoting. Knee 17:329–333

    Article  PubMed  Google Scholar 

  28. Webster KE, Wittwer JE, O’Brien J, Feller JA (2005) Gait patterns after anterior cruciate ligament reconstruction are related to graft type. Am J Sports Med 33(2):247–254

    Article  PubMed  Google Scholar 

  29. Zampeli F, Ntoulia A, Giotis D, Tsiaras V, Argyropoulou M, Pappas E, Georgoulis A (2012) Correlation between anterior cruciate ligament graft obliquity and tibial rotation during dynamic pivoting activities in patients with anatomic anterior cruciate ligament reconstruction: an in vivo examination. Arthroscopy 28(2):234–246

    Article  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Kate E. Webster.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Webster, K.E., Wotherspoon, S., Feller, J.A. et al. The effect of anterior cruciate ligament graft orientation on rotational knee kinematics. Knee Surg Sports Traumatol Arthrosc 21, 2113–2120 (2013). https://doi.org/10.1007/s00167-012-2310-1

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00167-012-2310-1

Keywords

Navigation