Abstract
Purpose
To investigate the feasibility and safety of a less invasive surgical approach to the distal medial aspect of the femur in supracondylar medial closing wedge osteotomy for the treatment of lateral compartment osteoarthritis of the knee. The aim of a less invasive approach is to minimize soft tissue disruption, reduce damage to neurovascular structures and thereby prevent muscle atrophy and optimize bone healing potential.
Methods
A human cadaver dissection study on the vascular and neural structures of the medial side of the distal femur was conducted. Surgical dissection (n = 4), cryomicrotomy and subsequent 3D reconstruction of the anatomy (n = 1), and surgical dissection after performance of a supracondylar osteotomy through a less invasive approach (n = 1) were performed in 6 legs in total.
Results
The surgical dissection and 3D reconstruction showed that a branch of the femoral artery, the distal genicular artery, supplies the distal area of the vastus medialis (VM) muscle. This artery has several branching patterns; crucial in the presented less invasive approach is its musculo-articular branch, which has an oblique course through the VM to the superomedial pole of the patella. The femoral nerve and saphenous nerve innervate the VM. These structures are at risk in the traditional subvastus approach, whereas no major damage was observed in the leg in which a less invasive approach was performed.
Conclusions
In this cadaveric dissection study, a less invasive approach to the medial side of the distal femur proved to be feasible and safe. Damage to the VM and its neurovascular structures is minimized as compared to the traditional subvastus approach.
Similar content being viewed by others
References
Basarir K, Erdemli B, Tuccar E, Esmer AF (2006) Safe zone for the descending genicular artery in the midvastus approach to the knee. Clin Orthop Relat Res 451:96–100
Brinkman JM, Hurschler C, Agneskirchner JD, Freiling D, van Heerwaarden RJ (2011) Axial and torsional stability of supracondylar femur osteotomies: biomechanical comparison of the stability of five different plate and osteotomy configurations. Knee Surg Sports Traumatol Arthrosc 19:579–587
Brinkman JM, Hurschler C, Staubli AE, van Heerwaarden RJ (2011) Axial and torsional stability of an improved single-plane and a new bi-plane osteotomy technique for supracondylar femur osteotomies. Knee Surg Sports Traumatol Arthrosc 19:1090–1098
Dubois G, Lopez R, Puwanarajah P, Noyelles L, Lauwers F (2010) The corticoperiosteal medial femoral supracondylar flap: anatomical study for clinical evaluation in mandibular osteoradionecrosis. Surg Radiol Anat 32(10):971–977
Farouk O, Krettek C, Miclau T, Schandelmaier P, Guy P, Tscherne H (1999) Minimally invasive plate osteosynthesis: does percutaneous plating disrupt femoral blood supply less than the traditional technique? J Orthop Trauma 13(6):401–406
Farouk O, Krettek C, Miclau T, Schandelmaier P, Tscherne H (1998) Effects of percutaneous and conventional plating techniques on the blood supply to the femur. Arch Orthop Trauma Surg 117(8):438–441
Freiling D, van HR, Staubli A, Lobenhoffer P (2010) The medial closed-wedge osteotomy of the distal femur for the treatment of unicompartmental lateral osteoarthritis of the knee. Oper Orthop Traumatol 22(3):317–334
Gunal I, Arac S, Sahinoglu K, Birvar K (1992) The innervation of vastus medialis obliquus. J Bone Joint Surg Br 74(4):624
Huang D, Wang HW, Xu DC, Wang HG, Wu WZ, Zhang HR (2011) An anatomic and clinical study of the adductor magnus tendon-descending genicular artery bone flap. Clin Anat 24(1):77–83
Jacobi M, Wahl P, Bouaicha S, Jakob RP, Gautier E (2010) Distal femoral varus osteotomy: problems associated with the lateral open-wedge technique. Arch Orthop Trauma Surg 131:725–728
Jojima H, Whiteside LA, Ogata K (2004) Anatomic consideration of nerve supply to the vastus medialis in knee surgery. Clin Orthop Relat Res 423:157–160
Kao FC, Tu YK, Su JY, Hsu KY, Wu CH, Chou MC (2009) Treatment of distal femoral fracture by minimally invasive percutaneous plate osteosynthesis: comparison between the dynamic condylar screw and the less invasive stabilization system. J Trauma 67(4):719–726
Kolb W, Guhlmann H, Windisch C, Marx F, Kolb K, Koller H (2008) Fixation of distal femoral fractures with the Less Invasive Stabilization System: a minimally invasive treatment with locked fixed-angle screws. J Trauma 65(6):1425–1434
Krettek C, Muller M, Miclau T (2001) Evolution of minimally invasive plate osteosynthesis (MIPO) in the femur. Injury 32 Suppl 3:SC14–SC23
Learmonth ID (1990) A simple technique for varus supracondylar osteotomy in genu valgum. J Bone Joint Surg Br 72(2):235–237
Marti RK, Schroder J, Witteveen A (2000) The closed wedge varus supracondylar osteotomy. Oper Tech Sports Med 8(1):48–55
McDermott AG, Finklestein JA, Farine I, Boynton EL, MacIntosh DL, Gross A (1988) Distal femoral varus osteotomy for valgus deformity of the knee. J Bone Joint Surg Am 70(1):110–116
Miniaci A, Grossmann SP, Jakob RP (1990) Supracondylar femoral varus osteotomy in the treatment of valgus knee deformity. Am J Knee Surg 3(2):65–73
Moayeri N, Bigeleisen PE, Groen GJ (2008) Quantitative architecture of the brachial plexus and surrounding compartments, and their possible significance for plexus blocks. Anesthesiology 108(2):299–304
Puddu G, Cipolla M, Cerullo G, Franco V, Gianni E (2007) Osteotomies: the surgical treatment of the valgus knee. Sports Med Arthrosc 15(1):15–22
Puddu G, Cipolla M, Cerullo G, Franco V, Gianni E (2010) Which osteotomy for a valgus knee? Int Orthop 34(2):239–247
Scheibel MT, Schmidt W, Thomas M, von Salis-Soglio G (2002) A detailed anatomical description of the subvastus region and its clinical relevance for the subvastus approach in total knee arthroplasty. Surg Radiol Anat 24(1):6–12
Schuurman JP, Go PM, Bleys RL (2009) Anatomical branches of the superior rectal artery in the distal rectum. Colorectal Dis 11(9):967–971
Smith TO, Nichols R, Harle D, Donell ST (2009) Do the vastus medialis obliquus and vastus medialis longus really exist? A systematic review. Clin Anat 22(2):183–199
Stahelin T, Hardegger F (2004) Incomplete, supracondylar femur osteotomy. A minimally invasive compression osteosynthesis with soft implant. Orthopade 33(2):178–184
Stahelin T, Hardegger F, Ward JC (2000) Supracondylar osteotomy of the femur with use of compression. Osteosynthesis with a malleable implant. J Bone Joint Surg Am 82(5):712–722
Thiranagama R (1990) Nerve supply of the human vastus medialis muscle. J Anat 170:193–198
van Heerwaarden RJ, Hurschler C, Brinkman J-M (2010) Superior axial stability of a new biplane osteotomy technique for supracondylar femur osteotomies fixed with an angular stable plate. Knee Surg Sports Traumatol Arthrosc 18 (suppl 1) (SCP10–1068):S101
Van Heerwaarden RJ, Wymenga AB, Freiling D, Lobenhoffer P (2007) Distal medial closed wedge varus femur osteotomy Stabilized with the tomofix plate fixator. Oper Tech Orthop 17:12–21
Yamamoto H, Jones DB Jr, Moran SL, Bishop AT, Shin AY (2010) The arterial anatomy of the medial femoral condyle and its clinical implications. J Hand Surg Eur 35(7):569–574
Ziran BH, Rohde RH, Wharton AR (2002) Lateral and anterior plating of intra-articular distal femoral fractures treated via an anterior approach. Int Orthop 26(6):370–373
Acknowledgments
The authors would like to thank Nizar Moayeri for his help with the 3D cryomicrotome analysis and Willem van Wolferen, Jan-Willem de Groot and Frank de Graaff for their help with the preparation of the legs. J.M. Brinkman would like to thank the Marti-Keuning Eckhardt Foundation for their support of his scientific work.
Conflict of interest
None declared by all authors.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Visser, J., Brinkman, J.M., Bleys, R.L.A.W. et al. The safety and feasibility of a less invasive distal femur closing wedge osteotomy technique: a cadaveric dissection study of the medial aspect of the distal femur. Knee Surg Sports Traumatol Arthrosc 21, 220–227 (2013). https://doi.org/10.1007/s00167-012-2133-0
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00167-012-2133-0