Abstract
Inaccurate coronal plane realignment is a common problem after high tibial osteotomy. It has been shown that lower limb rotation has an effect on the two-dimensional measurement of lower limb alignment. Although alignment errors are known to occur due to limb rotation, the magnitude of this effect is unknown. Navigation systems allow for the measurments of coronal plane alignment and dynamically rotational and sagittal plane. Our study evaluated the effect of rotational leg movements on coronal plane alignment as determined by image-free navigation. We hypothesized that a linear relationship exists between rotation and angular measurements. Eight cadavers were used, while three test conditions of the complete lower limbs were established: (1) solid knee arthrodesis, (2) provisional knee arthrodesis and (3) unconstrained knee conditions. Navigated measurements of coronal and sagittal lower limb axis were done initially without knee flexion for defined internal/external rotations of 5°, 10° and maximal values for all test series. Repeated test for the unconstrained knee included stepwise knee flexion of 5°, 10° and 20°. Statistical analysis comparing the test conditions 1, 2 and 3 and comparison between flexion movements of the unconstrained knee were done. Results revealed no significant differences between the different rotations of test condition 1 (mean 0.34°, SD 0.23, range, 0°–0.8°). Condition 2 similarly did not result in significant deviations (mean 0.51°, SD 0.24, range 0.1°–0.9°). Measurement deviations ranging from 0.4° to 4.3° were found for condition 3, the unconstrained knee. However, no statistically different testings from the arthrodesed knee were found (P = 0.099–0.410). Knee flexion from 5°, 10° or 20°, showed significant deviations (P < 0.05) for all rotations at all degrees of flexion. Rotation and flexion of 5° led to significant alignment errors of 3.4° and 2.8°, respectively, for internal and external rotations. Measurement failures due to the rotational movements of 1°–4° might add to additional sources of errors causing relevant under- or overcorrections of the mechanical leg axis. Discrepancies of the axis due to rotational movements as well as flexion of the knee joint can be avoided and corrected immediately with the help of navigation.
Similar content being viewed by others
References
Hankemeier S, Hufner T, Wang G, Kendoff D, Zheng G, Richter M, Gosling T, Nolte L, Krettek C (2005): Navigated intraoperative analysis of lower limb alignment. Arch Orthop Trauma Surg 125:531–535
Hankemeier S, Zheng G, Wang G, Zeichen J, Hüfner T, Krettek C (2005) Navigated open wedge high tibia osteotomy: advantages and disadvantages in comparison to the conventional technique in a cadaver study. Knee Surg Sports Traumatol Arthrosc accepted
Hsu RW, Himeno S, Coventry MB, Chao EY (1990) Normal axial alignment of the lower extremity and load-bearing distribution at the knee. Clin Orthop Relat Res 255:215–227
Kawakami H, Sugano N, Yonenobu K, Yoshikawa H, Ochi T, Hattori A, Suzuki N (2004) Effects of rotation on measurement of lower limb alignment for knee osteotomy. J Orthop Res 22:1248–1253
Keppler P, Gebhard F, Grutzner PA, Wang G, Zheng G, Hufner T, Hankemeier S, Nolte LP (2004) Computer aided high tibial open wedge osteotomy. Injury 35(Suppl 1):S-A68–S-A78
Keppler P, Suger G, Kinzl L, Strecker W (2002) Osteotomies in malalignments of the lower extremities. Chirurg 73:982–989
Khadem R, Yeh CC, Sadeghi-Tehrani M, Bax MR, Johnson JA, Welch JN, Wilkinson EP, Shahidi R (2000) Comparative tracking error analysis of five different optical tracking systems. Comput Aided Surg 5:98–107
Krettek C, Miclau T, Grun O, Schandelmaier P, Tscherne H (1998) Intraoperative control of axes, rotation and length in femoral and tibial fractures. Technical note. Injury 29(Suppl 3):C29–C39
Li Q, Zamorano L, Jiang Z, Gong JX, Pandya A, Perez R, Diaz F (1999) Effect of optical digitizer selection on the application accuracy of a surgical localization system—a quantitative comparison between the OPTOTRAK and flashpoint tracking systems. Comput Aided Surg 4:314–321
Marti CB, Gautier E, Wachtl SW, Jakob RP (2004) Accuracy of frontal and sagittal plane correction in open-wedge high tibial osteotomy. Arthroscopy 20:366–372
Matthews LS, Goldstein SA, Malvitz TA, Katz BP, Kaufer H (1988) Proximal tibial osteotomy. Factors that influence the duration of satisfactory function. Clin Orthop Relat Res 229:193–200
Paley D, Herzenberg JE, Tetsworth K, McKie J, Bhave A (1994) Deformity planning for frontal and sagittal plane corrective osteotomies. Orthop Clin North Am 25:425–465
Paley D, Maar DC, Herzenberg JE (1994) New concepts in high tibial osteotomy for medial compartment osteoarthritis. Orthop Clin North Am 25:483–498
Paley D, Tetsworth K (1992) Mechanical axis deviation of the lower limbs. Preoperative planning of multiapical frontal plane angular and bowing deformities of the femur and tibia. Clin Orthop Relat Res 280:65–71
Papachristou G (2004) Photoelastic study of the internal and contact stresses on the knee joint before and after osteotomy. Arch Orthop Trauma Surg 124:288–297
Pape D, Seil R, Adam F, Rupp S, Kohn D, Lobenhoffer P (2004) Imaging and preoperative planning of osteotomy of tibial head osteotomy. Orthopade 33:122–134
Prix R (2005) Opening-wedge osteotomy of the proximal tibia. Acta Chir Orthop Traumatol Cech 72:308–312
Saleh M, Harriman P, Edwards DJ (1991) A radiological method for producing precise limb alignment. J Bone Joint Surg Br 73:515–516
Saragaglia D, Roberts J (2005) Navigated osteotomies around the knee in 170 patients with osteoarthritis secondary to genu varum. Orthopedics 28:s1269–s1274
Sprenger TR, Doerzbacher JF (2003) Tibial osteotomy for the treatment of varus gonarthrosis. Survival and failure analysis to twenty-two years. J Bone Joint Surg Am 85–A:469–474
Wang G, Zheng G, Gruetzner PA, Mueller-Alsbach U, von Recum J, Staubli A, Nolte LP (2005) A fluoroscopy-based surgical navigation system for high tibial osteotomy. Technol Health Care 13:469–483
Wang G, Zheng G, Keppler P, Gebhard F, Staubli A, Mueller U, Schmucki D, Fluetsch S, Nolte LP (2005) Implementation, accuracy evaluation, and preliminary clinical trial of a CT-free navigation system for high tibial opening wedge osteotomy. Comput Aided Surg 10:73–86
Conflict of interest statement
No professional or private funding was received for this study. There were no conflicts of interest of any author of our manuscript.
Author information
Authors and Affiliations
Corresponding author
Additional information
Ethical statement: All experiments of our study have been approved by the Ethical Committee of the Hannover Medical School.
Rights and permissions
About this article
Cite this article
Kendoff, D., Citak, M., Pearle, A. et al. Influence of lower limb rotation in navigated alignment analysis: implications for high tibial osteotomies. Knee Surg Sports Traumatol Arthr 15, 1003–1008 (2007). https://doi.org/10.1007/s00167-007-0308-x
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00167-007-0308-x