Accuracy of needle placement in ACJ injections

  • Shoulder
  • Published:
Knee Surgery, Sports Traumatology, Arthroscopy Aims and scope

Abstract

Localization of the Acromioclavicular joint (ACJ) even at arthroscopic surgery may be difficult because of its small size, osteophytes, variable anatomy of the joint and capsule. Therefore injection of the ACJ in the clinic may well be inaccurate. The aim of this study was to review the clinical accuracy of needle placement in ACJ injections, if performed without the aid of image intensification. Sixty patients with 66 shoulders were injected in the Day Unit in our department. The joint was palpated clinically, and the needle was placed in the site thought to be in the AC Joint. An image intensifier was then used to check the position of the needle in the AP and axillary views. The needle was considered correctly placed if between the bony boundaries of the acromion and clavicle. This was found in only 26 injections (39.4%). The remaining 40 injections (60.6%) were misplaced, either laterally in 21 injections (31.8%), medially in 13 (19.8%), anteriorly in 3 (4.5%) and inferiorly in 3 injections (4.5%). Theses were then reinserted under image intensifier guidance. The misplaced injections would have lead to inaccurate clinical outcomes, and decision making. This study is similar to other studies in that X-ray guidance improves the accuracy of injections and surgery. However the potential error rate for the small, anatomically variable AC joint is high. There is a 60% potential for ACJ injections to be out of the joint if performed by palpation alone, and we recommend the routine use of image intensification guidance.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1 
Fig. 2 
Fig. 3 
Fig. 4 

Similar content being viewed by others

References

  1. Fongemie AE, Buss DD, Rolnick SJ (1998) Management of shoulder impingement syndrome and rotator cuff tears Am Fam Phys 57(4):667–674, 680–682

    Google Scholar 

  2. Horvath F, Kerry L (1984) Degenerative deformations of the acromioclavicular joint in the elderly Arch Gerontol Geriatr 3:259–265

    Article  PubMed  CAS  Google Scholar 

  3. Jacob AK, Sallay PI (1997) Therapeutic efficacy of corticosteroid injections in the acromioclavicular joint Biomed Sci Instrum 34:380–385

    PubMed  CAS  Google Scholar 

  4. Needell SD, Zlatkin MB, Sher JS, Murphy BJ, Uribe JW (1996) MR imaging of the rotator cuff: Peritendinous and bony abnormalities in an asymptomatic population AJR Am J Roentgenol 166:863–867

    PubMed  CAS  Google Scholar 

  5. Neer CS II (1990) Shoulder reconstruction WB Saunders, Philadelphia, pp 433–436

    Google Scholar 

  6. Partington PF, Broome GH (1998) Diagnostic injection around the shoulder: hit and miss? A cadaveric study of injection accuracy J Shoulder Elbow Surg 7(2):147–150

    Article  PubMed  CAS  Google Scholar 

  7. Rowe CR (1988) Injection technique for the shoulder and elbow Orthop Clin North Am 19(4):773–777

    PubMed  CAS  Google Scholar 

  8. Shaffer BS (1999) Painful conditions of the acromioclavicular joint J Am Acad Orthop Surg 7(3):176–188

    PubMed  CAS  Google Scholar 

  9. Yamakado K (2002) The targeting accuracy of subacromial injection to the shoulder: An arthrographic evaluation Arthroscopy 18(8):887–891

    Article  PubMed  Google Scholar 

  10. Raza K, Lee CY, Pilling D, Heaton S, Situnayake RD, Carruthers DM, Buckley CD, Gordon C, Salmon M (2003) Ultrasound guidance allows accurate needle placement and aspiration from small joints in patients with early inflammatory arthritis Rheumato (Oxford) 42(8):976–9

    Article  CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to H.G. Said.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Bisbinas, I., Belthur, M., Said, H. et al. Accuracy of needle placement in ACJ injections. Knee Surg Sports Traumatol Arthr 14, 762–765 (2006). https://doi.org/10.1007/s00167-006-0038-5

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00167-006-0038-5

Keywords

Navigation