Skip to main content
Log in

Intra-articular pull out of an interference screw after anterior cruciate ligament reconstruction

  • Sports Medicine
  • Published:
Knee Surgery, Sports Traumatology, Arthroscopy Aims and scope

Abstract

We report a rare case of late femoral interference screw migration in the posterior compartment of the knee after anterior cruciate ligament reconstruction. The graft was intact with no signs of damage. The screw was successfully removed through the posteromedial portal site and the patient regained full function of the knee

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3

Similar content being viewed by others

References

  1. Bach BR Jr (1989) Pitfalls of Kurousaka screw interference fixation for ACL surgery. Am J Knee Surg 2:76–82

    Google Scholar 

  2. Cooper DE, Wilson TW (1996) Clinical failure of tibial interference screw fixation after anterior cruciate ligament reconstruction. A case report of two cases. Am J Sports Med 24:693–697

    CAS  Google Scholar 

  3. Dworsky BD, Jewell BF, Bach BR Jr (1996) Interference screw divergence in endoscopic anterior cruciate ligament reconstruction. Arthroscopy 12:45–49

    Article  PubMed  CAS  Google Scholar 

  4. Feller JA, Webster KE (2003) A randomised comparison of patellar tendon and hamstring tendon anterior cruciate ligament reconstruction. Am J Sports Med 31:564–573

    PubMed  Google Scholar 

  5. Hallett A, Mohammed A (2003) Displaced femoral interference screw causing locked knee. Injury 34:797–798

    Article  PubMed  Google Scholar 

  6. Joseph BR (1998) Migration of femoral interference screw after anterior cruciate ligament reconstruction. Am J Knee Surg 11:32–34

    PubMed  Google Scholar 

  7. Karlakki SL, Downes ME (2003) Intraarticular migration of femoral interference screw: open or arthroscopic removal. Arthroscopy 19:19–21

    Article  Google Scholar 

  8. Mathews LS, Parks BG, Sabbagh RC (1998) Determination of fixation strength of large diameter interference screws. Arthroscopy 14:70–74

    Article  PubMed  Google Scholar 

  9. McGuire DA, Wolchok JC (1997) Consistent and accurate graft passage and interference screw guide wire placement during single incision anterior cruciate ligament reconstruction. Arthroscopy 13:526–529

    Article  PubMed  CAS  Google Scholar 

  10. Sidhu DS, Wroble RR (1997) Intraarticular migration of a femoral interference fit screw—a complication of anterior cruciate ligament reconstruction. Am J Sports Med 25:268–271

    PubMed  CAS  Google Scholar 

  11. Spindler KP, Bergfeld JA, Andrish JT (1993) Intraoperative complications of ACL surgery: avoidance and management. Orthopedics 6:425–430

    Google Scholar 

Download references

Acknowledgements

We would like to acknowledge the help rendered by Mr. M. A. Fazal, consultant orthopaedic surgeon in preparing the manuscript.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to P. Moonot.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Moonot, P., Allen, P. Intra-articular pull out of an interference screw after anterior cruciate ligament reconstruction. Knee Surg Sports Traumatol Arthrosc 14, 1004–1006 (2006). https://doi.org/10.1007/s00167-005-0010-9