Abstract
Accurate reconstruction of leg alignment is one important factor for long-term survival in total knee arthroplasty (TKA). Recent developments in computer-assisted surgery focused on systems improving TKA. The aim of the study is to compare the results of computer-assisted revision TKA with the conventional technique. We hypothize that a significantly better leg alignment and component orientation is achieved when using a navigation system for revision TKA. In a prospective study, two groups of 25 revision TKAs each were operated on using either a CT-free navigation system or the classical surgeon-controlled technique. The postoperative leg alignment was analysed on long-leg coronal and lateral X-rays. The mechanical limb axis was significantly better in the navigation-based group. Twenty-three patients (92%) in the computer-assisted group had a postoperative leg axis between 3° varus/valgus deviation, while 19 patients (76%) in the conventional group had a comparable result (p<0.05). Further, significant differences were seen for the coronal orientation of the femoral component. Computer-assisted revision TKA leads to a superior restoration of leg alignment compared with the conventional technique. Particularly the real-time presentation of the actual leg axis and the flexion and extension gaps is useful in revision TKA. Potential benefits in long-term outcome and functional improvement require additional investigation.
Similar content being viewed by others
References
Laskin RS (1976) Modular total knee-replacement arthroplasty: a review of eighty-nine patients. J Bone Joint Surg Am 58:766–773
Riley LH, Hungerford DS (1978) Geometric total knee replacement for treatment of the rheumatoid knee. J Bone Joint Surg Am 60:523–527
Scott WN, Rubinstein M, Scuderi G (1988) Results after knee replacement with a posterior cruciate-substituting prosthesis. J Bone Joint Surg Am 70:1163–1173
Bourne RB, Crawford HA (1998) Principles of revision total knee arthroplasty. Orthop Clin North Am 29:331–337
Gofton WT, Tsigaras H, Butler RA, Patterson JJ, Barrack RL, Rorabeck CH (2002) Revision total knee arthroplasty: fixation with modular stems. Clin Orthop 404:158–168
Dorr LD, Boiardo RA (1986) Technical considerations in total knee arthroplasty. Clin Orthop 205:5–11
Hofmann AA, Bachus KN, Wyatt RW (1991) Effect of the tibial cut on subsidence following total knee arthroplasty. Clin Orthop 269:63–69
Lotke PA, Ecker ML (1977) Influence of positioning of prosthesis in total knee replacement. J Bone Joint Surg Am 59:77–79
Ritter MA, Montgomery TJ, Zhou H, Keating ME, Faris PM, Meding JB (1999) The clinical significance of proximal tibial resection level in total knee arthroplasty. Clin Orthop 360:174–181
Dorr LD (2002) Session V: revision total knee replacement: an overview. Clin Orthop 404:143–144
Sharkey PF, Hozack WJ, Rothman RH, Shastri S, Jacoby SM (2002) Insall award paper. Why are total knee arthroplasties failing today? Clin Orthop 404:7–13
Figgie HE, Goldberg VM, Heiple KG, Moller HS, Gordon NH (1986) The influence of tibial-patellofemoral location on function of the knee in patients with the posterior stabilized condylar knee prosthesis. J Bone Joint Surg Am 68:1035–1040
Laskin RS (2002) Joint line position restoration during revision total knee replacement. Clin Orthop 404:169–171
Partington PF, Sawhney J, Rorabeck CH, Barrack RL, Moore J (1999) Joint line restoration after revision total knee arthroplasty. Clin Orthop 367:165–171
Jenny JY, Boeri C (2001) Navigated implantation of total knee endoprostheses: a comparative study with conventional instrumentation. Z Orthop Ihre Grenzgeb 139:117–119
Mielke RK, Clemens U, Jens JH, Kershally S (2001) Navigation in knee endoprosthesis implantation: preliminary experiences and prospective comparative study with conventional implantation technique. Z Orthop Ihre Grenzgeb 139:109–116
Sparmann M, Wolke B, Czupalla H, Banzer D, Zink A (2003) Positioning of total knee arthroplasty with and without navigation support: a prospective, randomised study. J Bone Joint Surg Br 85:830–835
Engh GA, Ammeen DJ (1999) Bone loss with revision total knee arthroplasty: defect classification and alternatives for reconstruction. Instr Course Lect 48:167–175
Buechel FF, Pappas MJ (1986) The New Jersey low-contact-stress knee replacement system: biomechanical rationale and review of the first 123 cemented cases. Arch Orthop Trauma Surg 105:197–204
Mahaluxmivala J, Bankes MJ, Nicolai P, Aldam CH, Allen PW (2001) The effect of surgeon experience on component positioning in 673 press fit condylar posterior cruciate-sacrificing total knee arthroplasties. J Arthroplasty 16:635–640
Rand JA, Coventry MB (1988) Ten-year evaluation of geometric total knee arthroplasty. Clin Orthop 232:168–173
Jeffery RS, Morris RW, Denham RA (1991) Coronal alignment after total knee replacement. J Bone Joint Surg Br 73:709–714
Hvid I, Nielsen S (1984) Total condylar knee arthroplasty. Prosthetic component positioning and radiolucent lines. Acta Orthop Scand 55:160–165
Ritter MA, Faris PM, Keating EM, Meding JB (1994) Postoperative alignment of total knee replacement: its effect on survival. Clin Orthop 309:153–156
Petersen TL, Engh GA (1988) Radiographic assessment of knee alignment after total knee arthroplasty. J Arthroplasty 3:67–72
Jenny JY, Mielke RK, Kohler S, Kiefer H, Konermann K, Boeri C, Clemens U, Ratayski H (2003) Total knee prosthesis implantation with a non image based navigation system: a multicentric analysis. In: Proceedings of the 70th annual meeting AAOS, American Academy of Orthopedic Surgeons, New Orleans, p 96
Plaskos C, Hodgson AJ, Inkpen K, McGraw RW (2002) Bone cutting errors in total knee arthroplasty. J Arthroplasty 17:698–705
Rand JA (1998) Modular augments in revision total knee arthroplasty. Orthop Clin North Am 29:347–353
Noda T, Yasuda S, Nagano K, Takahara Y, Namba Y, Inoue H (2000) Clinico-radiological study of total knee arthroplasty after high tibial osteotomy. J Orthop Sci 5:25–36
Griffin FM, Math K, Scuderi GR, Insall JN, Poilvache PL (2000) Anatomy of the epicondyles of the distal femur: MRI analysis of normal knees. J Arthroplasty 15:354–359
Stiehl JB, Abbott BD (1995) Morphology of the transepicondylar axis and its application in primary and revision total knee arthroplasty. J Arthroplasty 10:785–789
Scuderi GR, Insall JN (1992) Total knee arthroplasty: current clinical perspectives. Clin Orthop 276:26–32
Insall JN, Lachiewicz PF, Burstein AH (1982) The posterior stabilized condylar prosthesis: a modification of the total condylar design. Two to four-year clinical experience. J Bone Joint Surg Am 64:1317–1323
Cope MR, O’Brien BS, Nanu AM (2002) The influence of the posterior cruciate ligament in the maintenance of joint line in primary total knee arthroplasty: a radiologic study. J Arthroplasty 17:206–208
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Perlick, L., Bäthis, H., Perlick, C. et al. Revision total knee arthroplasty: a comparison of postoperative leg alignment after computer-assisted implantation versus the conventional technique. Knee Surg Sports Traumatol Arthrosc 13, 167–173 (2005). https://doi.org/10.1007/s00167-004-0507-7
Received:
Accepted:
Published:
Issue Date: