Accuracy of pulse oximetry in the intensive care unit
Download PDF
Your article has downloaded

Similar articles being viewed by others

Slider with three articles shown per slide. Use the Previous and Next buttons to navigate the slides or the slide controller buttons at the end to navigate through each slide.

A multicentre prospective observational study comparing arterial blood gas values to those obtained by pulse oximeters used in adult patients attending Australian and New Zealand hospitals

09 January 2020

Janine Pilcher, Laura Ploen, … Richard Beasley

Accuracy of two pulse-oximetry measurements for INTELLiVENT-ASV in mechanically ventilated patients: a prospective observational study

26 April 2021

Shinshu Katayama, Jun Shima, … Shin Nunomiya

Agreement between pulse oximetry and arterial oxygen saturation measurement in critical care patients during COVID-19: a cross-sectional study

21 January 2023

Arthur James, Matthieu Petit, … Jean-Michel Constantin

Facing SpO2 and SaO2 discrepancies in ICU patients: is the perfusion index helpful?

07 August 2019

Mark Thijssen, Loes Janssen, … Norbert Foudraine

Determination of oxygen saturation compared to a prescribed target range using continuous pulse oximetry in acutely unwell medical patients

26 October 2021

James C. P. Harper, Ruth Semprini, … Richard Beasley

Clinical evaluation for the pharyngeal oxygen saturation measurements in shocked patients

01 November 2022

Eman Arafa Hassan, Sherouk Nasser Mohamed, … Nadia Taha Ahmed

The ability of Oxygen Reserve Index® to detect hyperoxia in critically ill patients

16 May 2022

Hugues de Courson, Thomas Julien-Laferrière, … Matthieu Biais

Impact of COVID-19 on the association between pulse oximetry and arterial oxygenation in patients with acute respiratory distress syndrome

27 January 2022

Lee S. Nguyen, Marion Helias, … Mathieu Jozwiak

Evaluation of time courses of agreement between minutely obtained transcutaneous blood gas data and the gold standard arterial data from spontaneously breathing Asian adults, and various subgroup analyses

29 May 2020

Akira Umeda, Masahiro Ishizaka, … Sarah Kesler

Download PDF
  • Original
  • Published: 21 April 2014

Accuracy of pulse oximetry in the intensive care unit

  • A. Louw1,
  • C. Cracco2,
  • C. Cerf1,
  • A. Harf3,
  • P. Duvaldestin1,
  • F. Lemaire2 &
  • …
  • L. Brochard2 

Intensive Care Medicine volume 27, pages 1606–1613 (2001)Cite this article

  • 2771 Accesses

  • 187 Citations

  • 14 Altmetric

  • Metrics details

Abstract.

Objective: Pulse oximetry (SpO2) is a standard monitoring device in intensive care units (ICUs), currently used to guide therapeutic interventions. Few studies have evaluated the accuracy of SpO2 in critically ill patients. Our objective was to compare pulse oximetry with arterial oxygen saturation (SaO2) in such patients, and to examine the effect of several factors on this relationship. Design: Observational prospective study. Setting: A 26-bed medical ICU in a university hospital. Patients: One hundred two consecutive patients admitted to the ICU in whom one or serial arterial blood gas analyses (ABGs) were performed and a reliable pulse oximeter signal was present. Interventions: For each ABG, we collected SaO2, SpO2, the type of pulse oximeter, the mode of ventilation and requirement for vasoactive drugs. Measurements and results: Three hundred twenty-three data points were collected. The mean difference between SpO2 and SaO2 was –0.02% and standard deviation of the differences was 2.1%. From one sample to another, the fluctuations in SpO2 to arterial saturation difference indicated that SaO2 could not be reliably predicted from SpO2 after a single ABG. Subgroup analysis showed that the accuracy of SpO2 appeared to be influenced by the type of oximeter, the presence of hypoxemia and the requirement for vasoactive drugs. Finally, high SpO2 thresholds were necessary to detect significant hypoxemia with good sensitivity. Conclusion: Large SpO2 to SaO2 differences may occur in critically ill patients with poor reproducibility of SpO2. A SpO2 above 94% appears necessary to ensure a SaO2 of 90%.

Download to read the full article text

Working on a manuscript?

Avoid the common mistakes

Author information

Authors and Affiliations

  1. Anesthesiology Department and Surgical Intensive Care Unit, Henri Mondor Hospital, Assistance Publique-Hôpitaux de Paris, University Paris XII, Créteil, France, France

    A. Louw, C. Cerf & P. Duvaldestin

  2. Medical Intensive Care Unit, Henri Mondor Hospital, Assistance Publique-Hôpitaux de Paris, University Paris XII, Créteil, France, France

    C. Cracco, F. Lemaire & L. Brochard

  3. Physiology Department, Henri Mondor Hospital, Assistance Publique-Hôpitaux de Paris, University Paris XII, Créteil, France, France

    A. Harf

Authors
  1. A. Louw
    View author publications

    You can also search for this author in PubMed Google Scholar

  2. C. Cracco
    View author publications

    You can also search for this author in PubMed Google Scholar

  3. C. Cerf
    View author publications

    You can also search for this author in PubMed Google Scholar

  4. A. Harf
    View author publications

    You can also search for this author in PubMed Google Scholar

  5. P. Duvaldestin
    View author publications

    You can also search for this author in PubMed Google Scholar

  6. F. Lemaire
    View author publications

    You can also search for this author in PubMed Google Scholar

  7. L. Brochard
    View author publications

    You can also search for this author in PubMed Google Scholar

Additional information

Final revision received: 5 July 2001

Electronic Publication

Rights and permissions

Reprints and Permissions

About this article

Verify currency and authenticity via CrossMark

Cite this article

Louw, A., Cracco, C., Cerf, C. et al. Accuracy of pulse oximetry in the intensive care unit. Intensive Care Med 27, 1606–1613 (2001). https://doi.org/10.1007/s001340101064

Download citation

  • Received: 16 November 2000

  • Accepted: 19 July 2001

  • Published: 21 April 2014

  • Issue Date: October 2001

  • DOI: https://doi.org/10.1007/s001340101064

Share this article

Anyone you share the following link with will be able to read this content:

Sorry, a shareable link is not currently available for this article.

Provided by the Springer Nature SharedIt content-sharing initiative

  • Pulse oximetry Monitoring Oxygen saturation Intensive care
Download PDF

Working on a manuscript?

Avoid the common mistakes

Advertisement

Over 10 million scientific documents at your fingertips

Switch Edition
  • Academic Edition
  • Corporate Edition
  • Home
  • Impressum
  • Legal information
  • Privacy statement
  • California Privacy Statement
  • How we use cookies
  • Manage cookies/Do not sell my data
  • Accessibility
  • FAQ
  • Contact us
  • Affiliate program

Not logged in - 3.239.117.1

Not affiliated

Springer Nature

© 2023 Springer Nature Switzerland AG. Part of Springer Nature.