Setting safe and effective suction pressure: the effect of using a manometer in the suction circuit

  • ORIGINAL
  • Published:
Intensive Care Medicine Aims and scope Submit manuscript

Abstract

Objectives: To establish the levels of pressure used to perform tracheal suction (TS) and if they are affected by having a manometer visible in the suction circuit.¶Design: A bench test evaluation of simulated tracheal suction.¶Setting: Physiotherapy department of a major teaching hospital in Melbourne, Australia.¶Participants: Sixty-four nurses and physiotherapists who regularly apply TS to patients in the intensive care units of this hospital.¶Interventions: All subjects used both circuit A (without a visible manometer) and B (with a visible manometer) in a predetermined random order. For both, subjects adjusted the suction control tap to where they said a safe and effective pressure (set pressure) was delivered and then occluded the suction catheter as though suctioning (applied pressure). Subjects then completed a questionnaire on their current TS practise.¶Measurements and results: All set pressures (mean = 228.57 mmHg) and all applied pressures (mean = 359.52 mmHg) were significantly higher (P < .001) when compared to the expected pressures (mean = 135 mmHg). Pressures set without a visible manometer (circuit A) were significantly higher (P < .05) than those using a visible manometer (circuit B) but the applied pressures were not significantly different (P = .166). Neither the investigator (P = .618) or the test order (P = .167) had a significant effect on the outcome. Questionnaire results showed 31 % of subjects considered 100–170 mmHg a safe and effective suction pressure whilst none reported using an objective means of measuring pressure.¶Conclusion: All pressures in both circuits were significantly higher than those recommended as safe in the literature. In addition, pressures were unaffected by the inclusion of a visible manometer in the suction circuit.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Author information

Authors and Affiliations

Authors

Additional information

Received: 31 May 1999 Final revision received: 12 November 1999 Accepted: 15 November 1999

Rights and permissions

Reprints and permissions

About this article

Cite this article

Donald, K., Robertson, V. & Tsebelis, K. Setting safe and effective suction pressure: the effect of using a manometer in the suction circuit. Intensive Care Med 26, 15–19 (2000). https://doi.org/10.1007/s001340050006

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/s001340050006

Keywords

Navigation