Literatur
Ad-hoc-Arbeitsgruppe Innenraumrichtwerte der IRK/AOLG (2013) Richtwerte für Glykolether und Glykolester in der Innenraumluft. Bundesgesundheitsbl Gesundheitsforsch Gesundheitsschutz 56:286–320
EU-SCCS (2016) Opinion on 2-Phenoxyethanol. Final version of 6 October 2016. SCCS/1575/16. Scientific Committee on Consumer Safety. European Commission. Health and Food Safety. L-2920 Luxembourg. https://ec.europa.eu/health/sites/health/files/scientific_committees/consumer_safety/docs/sccs_o_195.pdf . Zugegriffen: 4. Dez. 2017
Hartwig A, MAK-Kommission (2017) 2-Phenoxyethanol. Nachtrag 2017. Abgeschlossen am 24.02.2016. MAK-Collection Occup Health Saf 2(2):836–871. https://doi.org/10.1002/3527600418.mb12299kskd0063/pdf
OECD (2004) Ethylene glycol phenyl ether (CAS N°: 122-99-6). Organization for Economic Co-operation and Development. SIDS Initial Assessment Report. Paris, France
Gabb HA, Blake C (2016) An informatics approach to evaluating combined chemical exposures from consumer products: A case study of asthma-associated chemicals and potential endocrine disruptors. Environ Health Perspect 124:1155–1165
Pastor-Nieto MA, Alcántara-Nicolás F, Melgar-Molero V et al (2017) Preservatives in personal hygiene and cosmetic products, topical medications, and household cleaners in Spain. Actas Dermosifiliogr 108:758–770
DFG (1998) 2-Phenoxyethanol. In: Deutsche Forschungsgemeinschaft: Gesundheitsschädliche Arbeitsstoffe. Toxikologisch-arbeitsmedizinische Begründungen von MAK-Werten, 26. Aufl. Wiley-VCH, Weinheim
Lux W, Mohr S, Heinzow B, Ostendorp G (2001) Belastung der Raumluft privater Neubauten mit flüchtigen organischen Substanzen. Bundesgesundheitsbl Gesundheitsforsch Gesundheitsschutz 44:619–624
UBA (2008) Vergleichswerte für flüchtige organische Verbindungen (VOC und Aldehyde) in der Innenraumluft von Haushalten in Deutschland. Umweltbundesamt. Bundesgesundheitsbl Gesundheitsforsch Gesundheitsschutz 51:109–112
Hofmann H, Erdmann G, Müller A (2014) Zielkonflikt energieeffiziente Bauweise und gute Raumluftqualität – Datenerhebung für flüchtige organische Verbindungen in der Innenraumluft von Wohn- und Bürogebäuden (Lösungswege). Anhang zum Abschlussbericht. http://www.agoef.de/fileadmin/user_upload/dokumente/forschung/AGOEF-Abschlussericht_VOCDB_II_Anhang-nicht-barrierefrei.pdf . Zugegriffen: 4. Dez. 2017
Schlechter N, Pohl K, Barig A et al (2004) Beurteilung der Raumluftqualität an Büroarbeitsplätzen. Gefahrstoffe – Reinhalt Luft 64:95–99
von Hahn N, van Gelder R, Breuer D et al (2011) Ableitung von Innenraumarbeitsplatz-Referenzwerten. Gefahrstoffe – Reinhalt Luft 71:314–322
Neumann HD, Buxtrup M, Benitez S, Breuer D (2014) VOC-Konzentrationen in Schulen. Gefahrstoffe – Reinhalt Luft 74:79–84
Fromme H, Heitmann D, Dietrich S et al (2008) Raumluftqualität in Schulen - Belastung von Klassenräumen mit Kohlendioxid (CO 2 ), flüchtigen organischen Verbindungen (VOC), Aldehyden, Endotoxinen und Katzenallergenen. Gesundheitswesen 70:88–97
Ostendorp G, Riemer D, Harmel K, Heinzow B (2009) Aktuelle Hintergrundwerte zur VOC-Belastung in Schulen und Kindergärten in Schleswig-Holstein. Umweltmed Forsch Prax 14:135–152
Fromme H, Lahrz T, Burkhardt R et al (2016) Luftqualität in Kindertagesstätten - Belastung mit Kohlendioxid (CO 2 ), flüchtigen organischen Verbindungen (VOC) und Feinstäuben – LUPE 3. Gefahrstoffe – Reinhalt Luft 76:55–61
Scognamiglio J, Jones L, Letizia CS, Api AM (2012) Fragrance material review on 2-phenoxyethanol. Food Chem Toxicol 50(Suppl 2):244–255
Multigner L, Brik BE, Arnaud I et al (2007) Glycol ethers and semen quality: a cross-sectional study among male workers in the Paris Municipality. Occup Environ Med 64:467–473
Labat L, Humbert L, Dehon B et al (2008) Determination of urinary metabolites of glycol ethers by gas chromatography mass spectrometry. Ann Toxicol Anal 20:227–232
Fromme H, Nitschke L, Boehmer S et al (2013) Exposure of German residents to ethylene and propylene glycol ethers in general and after cleaning scenarios. Chemosphere 90:2714–2721
Göen T, Dewes P, Aretz J, Lakemeyer M (2001) Internal exposure of the general population to phenoxyethanol. Int J Hyg Environ Health 204:277
Garlantézec R, Multigner L, Labat L et al (2012) Urinary biomarkers of exposure to glycol ethers and chlorinated solvents during pregnancy: determinations of exposure and comparison with indirect methods of exposure assessment. Occup Environ Med 69:62–70
Howes D (1989) Absorption and metabolism of 2-phenoxyethanol in rat and man. Unilever Environmental Laboratory, Sharnbrook
Breslin WJ, Phillips JE, Lomax LG et al (1991) Hemolytic activity of ethylene glycol phenyl ether (EGPE) in rabbits. Fund Appl Toxicol 17:466–481
Ma-Hock L et al (2007) Phenoxyethanol – Subacute 14-day inhalation study in Wistar rats – liquid aerosol exposure. BASF AG, Department of Experimental Toxicology and Ecology, Ludwigshafen
Wieslander G, Norbäck D (2010) Ocular symptoms, tear film stability, nasal patency, and biomarkers in nasal lavage in indoor painters in relation to emissions from water-based paint. Int Arch Occup Environ Health 83:733–741
Howes D (1988) Absorption and metabolism of 2-phenoxyethanol in rat and man. Cosmet Toilet 103:75
Heindel JJ, Gulati DK, Russell VS et al (1990) Assessment of ethylene glycol monbutyl and monophenyl ether reproductive toxicity using a continuous breeding protocol in Swiss CD-1 mice. Fund Appl Toxicol 15:683–696
Martinetz D, Hartwig R (1998) Taschenbuch der Riechstoffe. Verlag Harri Deutsch, Frankfurt am Main
Ad-hoc-Arbeitsgruppe Innenraumrichtwerte der IRK/AOLG (2012) Richtwerte für die Innenraumluft: erste Fortschreibung des Basisschemas. Bundesgesundheitsbl Gesundheitsforsch Gesundheitsschutz 55:279–290
Rights and permissions
About this article
Cite this article
Richtwerte für 2-Phenoxyethanol in der Innenraumluft. Bundesgesundheitsbl 61, 488–493 (2018). https://doi.org/10.1007/s00103-018-2707-1
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00103-018-2707-1