Wie sicher sind Blutzuckermesssysteme?

Erfahrungen des Bundesinstitutes für Arzneimittel und Medizinprodukte mit den dort bis Ende 2005 eingegangenen Meldungen

Are blood glucose analyzers safe? Experiences of the BfArM based on all notifications received until end of 2005

  • Originalien und Übersichtsarbeiten
  • Published:
Bundesgesundheitsblatt - Gesundheitsforschung - Gesundheitsschutz Aims and scope

Zusammenfassung

Seit Implementierung der Richtlinie 98/79/ EG des Europäischen Parlaments und des Rates vom 27. Oktober 1998 über In-vitro-Diagnostika (IVD-Richtlinie) müssen Vorkommnisse und im Feld durchgeführte korrektive Maßnahmen in Verbindung mit In-vitro-Diagnostika (IVD) den zuständigen nationalen Behörden gemeldet werden. In Deutschland sind dies das Bundesinstitut für Arzneimittel und Medizinprodukte (BfArM) und das Paul-Ehrlich-Institut (PEI), wobei Letzteres jedoch ausschließlich für immunhämatologische (einschließlich Gewebetypisierung) und infektiologische Tests zu den in Anhang II der Richtlinie aufgeführten Produkten zuständig ist. Zwischen Anfang 1999 und Ende 2005 sind beim BfArM 653 Meldungen zu IVD eingegangen. Von diesen betreffen 128 die Geräte und Sensoren (Teststreifen) zur Blutzuckerselbstmessung. Die beim BfArM zu diesen Produkten eingegangenen Meldungen kamen gleich häufig von Anwendern und Herstellern (jeweils 44,5 %). Die von den Herstellern durchgeführten Untersuchungen konnten in 31 Fällen einen Produktfehler aus schließen bzw. in 35 Fällen nicht anwenderbedingte Produktfehler nachweisen. Von den übrigen Fällen beruhten 29 auf Anwenderfehlern oder konnten, da die Produkte den Herstellern nicht oder nur teilweise zur Überprüfung zur Verfügung standen, nicht abschließend aufgeklärt werden (n=33). Die nachgewiesenen Produktfehler betrafen in 24 Fällen die Teststreifen und nur in 11 Fällen die Messgeräte. Korrektive Maßnahmen wurden von den Herstellern in 34 Fällen durchgeführt. Diese erfolgten in 27 Fällen in Verbindung mit einem zuvor nachgewiesenen Produktmangel. In 7 weiteren Fällen erfolgten jedoch präventive Maßnahmen aufgrund zusätzlicher, bei der Überprüfung durch den Hersteller gewonnener Erkenntnisse. Die erhaltenen Ergebnisse und die seit 1999 gewonnene Erfahrung zeigen, dass das behördliche System zur Marktüberwachung ein etabliertes Verfahren zur Gewährleistung der Sicherheit in Verkehr befindlicher Blutzuckermesssysteme darstellt. Der hohe Anteil an Meldungen in Verbindung mit Produkten zur Selbstmessung der Blutglukose zeigt weiterhin, dass so genannte Over-the-counter-(OTC-)Produkte, zu denen Blutzuckermesssysteme zu rechnen sind, einen nicht unerheblichen Schwerpunkt im Gesamtsystem der behördlichen Marktüberwachung bilden.

Abstract

Since implementation of the Directive 98/79/EC of the European Parliament and of the Council on in vitro Diagnostic Medical Devices (IVD Directive), issues and field corrective actions on in vitro diagnostic medical devices (IVDMD) have to be reported to the national competent authorities. In Germany these are the BfArM and the Paul Ehrlich Institute; the latter is responsible for Annex II products used for immune hematology, tissue typing and infectiology testing. Between the beginning of 1999 and the end of 2005 BfArM received n=653 notifications on IVDMD. From these n=128 concerned analyzers and sensors (test strips) for self monitoring of blood glucose. A similar quantity of cases was reported by users and manufacturers (44.5 %). In n=31 of these cases a product defect was not confirmed after the investigation of the products by the manufacturers. Product failures were confirmed in n=35 cases. The remaining cases were caused by user errors (n= 29) or the data were inconclusive (n=33), predominantly because the products were not or only partly available for investigation by the manufacturers. In those cases where product failure had been verified n=24 affected the sensors (test strips) and n=11 the analyzers. Corrective actions were performed by the manufacturers in n=34 cases. From these n=27 were cases in which a product failure had been detected. However, in n=7 cases the investigations of the manufacturers were followed by preventive corrective actions because the manufacturers became aware of potential causes of future product failures. The obtained results and experiences since 1999 show that the governmental system for post-marketing surveillance of products for self testing of blood glucose is an established tool to ensure product safety. Regarding the proportion of notifications concerning these over the counter (OTC) products, it becomes obvious that they are a focus for action for the competent surveillance authorities.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Literatur

  1. Permutt MA, Wasson J, Cox N (2005) Genetic epidemiology of diabetes. J Clin Invest 115:1431–1439

    Article  PubMed  CAS  Google Scholar 

  2. Skyler JS, Oddo C (2002) Diabetes. Metab Res Rev 18(Suppl 3):S21–S26

    Article  Google Scholar 

  3. Passa P (2002) Diabetes. Metab Res Rev 18(Suppl 3):S3–S8

    Article  Google Scholar 

  4. Zimmet P, Alberti KG, Shaw J (2001) Global and social implications of the diabetes epidemic. Nature 414:782–787

    Article  PubMed  CAS  Google Scholar 

  5. Winkelmann BR, März W, Boehm BO et al. (2001) Rationale and design of the LURIC study—a resource for functional genomics, pharmacogenomics and long term prognosis of cardiovascular disease. Pharmacogenomics 2(Suppl 1):S1–73

    Article  PubMed  CAS  Google Scholar 

  6. Deutsche Diabetesgesellschaft (2006) Diabetes—Eine Volkskrankheit im Schattendasein? Internet: http://www:deutsche-diabetes-gesellschaft.de/redaktion/patienten/umfrage.html

  7. Directive 98/79/EC of the European Parliament and of the Council of 27 October 1998 on In Vitro Diagnostic Medical Devices (Official Journal L 331, pp 1–37/http://www.europa.eu.int/eur-lex/en/index.html)

  8. Medizinproduktegesetz (MPG) in der Fassung der Bekanntmachung vom 7. August 2002 (BGBl. I S. 3146/http://www.bfarm.de/de/Medizinprodukte/mp_recht/index.php)

  9. Guidelines on a Medical Devices Vigilance System (MEDDEV 2.12-1 rev.4/http://www.europa.eu.int/comm/enterprise/medical_devices/guidelinesmed/baseguidelines.htm)

  10. Medical Devices Post Market Surveillance: National Competent Authority Report Exchange Criteria (GHTF/SG2/N20R10:2002/http://www.ghtf.org)

  11. Medizinprodukte-Sicherheitsplanverordnung (MPSV) vom 24. Juni 2002 (BGBl. I S. 2131/http://www.bfarm.de/de/Medizinprodukte/mp_recht/index.php)

  12. Die Anforderungen der Medizinprodukte-Sicherheitsplanverordnung für In-vitro-Diagnostika im Rahmen des Medizinproduktegesetzes Medizin Produkte Recht 4, 2002: 120–133/http://www.vdgh.de

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to R. Siekmeier.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Siekmeier, R., Lütz, J. Wie sicher sind Blutzuckermesssysteme?. Bundesgesundheitsbl. 49, 1212–1218 (2006). https://doi.org/10.1007/s00103-006-0091-8

Download citation

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00103-006-0091-8

Schlüsselwörter

Keywords

Navigation