Skip to main content

Advertisement

Log in

Clinical and functional outcomes of internal fixation with intertrochanteric antegrade nail in older patients with proximal extracapsular femoral fractures

  • Original Article
  • Published:
European Journal of Trauma and Emergency Surgery Aims and scope Submit manuscript

Abstract

Purpose

The intertrochanteric Trigen Intertan® nail (Smith & Nephew, Memphis, TN) is a popular fixation device for proximal extracapsular femoral fractures (PEFFs). We evaluated clinical and functional outcomes in patients with PEFFs treated with Trigen Intertan® nail.

Methods

In a single-site, prospective observational study, clinical and functional parameters were recorded for all patients admitted to the Emergency Department with PEFFs from June 2008 through June 2011. Patients with severe cognitive impairment, severe disability, neoplastic pathological fractures, or suffering from terminal illnesses were not eligible for the study. Fractures were classified according to the AO/OTA classification system. Preoperative physical fitness was assessed via the American Association of Anaesthetists (ASA) score. The Barthel index was used to quantify the level of physical function before fracture and at follow-up.

Results

One-hundred thirty-five patients with PEFFs were eligible for inclusion during the 3-year survey (mean age 83.2 ± 9.5 years; 82 % females). Fracture type distribution was as follows: A1.1 = 18 %, A1.2 = 7 %, A1.3 = 5 %, A2.1 = 44 %, A2.2 = 21 %, A2.3 = 5 %. All patients were treated with Trigen Intertan® nail. Two patients experienced a fracture of the femoral shaft during the insertion of a long nail for an A2.3 fracture. Weight-bearing was allowed between the third and tenth postoperative day depending on pain tolerance and general conditions. No loss of reduction, collapse of the femoral neck, nonunion or fixation failure were observed. Two patients died within 10 days postoperatively, and nine within 6 months after surgery. Functional status 1 month after surgery was lower than pre-fractural levels, and improved over follow-up. At 6 months, functional status was comparable to the pre-fractural level.

Conclusions

Trigen Intertan® produces highly satisfactory clinical and functional results in older patients with PEFFs. Complete functional recovery is obtained on average 6 months after surgery.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3

Similar content being viewed by others

References

  1. Senohradski K, Markovic-Denic L, Lesic A, Bumbasirevic V, Bumbasirevic M. Trends in the incidence of hip fractures. Osteoporos Int. 2013;24:1759–63. doi:10.1007/s00198-012-2244-y.

    Article  CAS  PubMed  Google Scholar 

  2. Ngobeni RS. Mortality in elderly patients with intertrochanteric fractures: three years’ experience. SA Orthop J. 2010;9:55–60.

    Google Scholar 

  3. Braithwaite RS, Col NF, Wong JB. Estimating hip fracture morbidity, mortality and costs. J Am Geriatr Soc. 2003;51:364–70.

    Article  PubMed  Google Scholar 

  4. Magaziner J, Fredman L, Hawkes W, Hebel JR, Zimmerman S, Orwig DL, Wehren L. Changes in functional status attributable to hip fracture: a comparison of hip fracture patients to community-dwelling aged. Am J Epidemiol. 2003;157:1023–31. doi:10.1093/aje/kwg081.

    Article  PubMed  Google Scholar 

  5. Hallberg I, Bachrach-Lindström M, Hammerby S, Toss G, Ek AC. Health-related quality of life after vertebral or hip fracture: a seven-year follow-up study. BMC Musculoskelet Disord. 2009;10:135. doi:10.1186/1471-2474-10-135.

    Article  PubMed Central  PubMed  Google Scholar 

  6. Zlowodzki M, Tornetta P 3rd, Haidukewych G, Hanson BP, Petrisor B, Swiontkowski MF, Schemitsch EH, Giannoudis PV, Bhandari M. Femoral neck fractures: evidence versus beliefs about predictors of outcome. Orthopedics. 2009;32(4). pii: orthosupersite.com/view.asp?rID = 38062.

  7. Moja L, Piatti A, Pecoraro V, Ricci C, Virgili G, Salanti G, Germagnoli L, Liberati A, Banfi G. Timing matters in hip fracture surgery: patients operated within 48 hours have better outcomes. A meta-analysis and meta-regression of over 190,000 patients. PLoS ONE. 2012;7:e46175. doi:10.1371/journal.pone.0046175.

    Article  CAS  PubMed Central  PubMed  Google Scholar 

  8. Rupprecht M, Grossterlinden L, Ruecker AH, de Oliveira AN, Sellenschloh K, Nüchtern J, Püschel K, Morlock M, Rueger JM, Lehmann W. A comparative biomechanical analysis of fixation devices for unstable femoral neck fractures: the Intertan versus cannulated screws or a dynamic hip screw. J Trauma. 2011;71:625–34. doi:10.1097/TA.0b013e31820e86e6.

    Article  PubMed  Google Scholar 

  9. Rupprecht M, Grossterlinden L, Sellenschloh K, Hoffmann M, Püschel K, Morlock M, Rueger JM, Lehmann W. Internal fixation of femoral neck fractures with posterior comminution: a biomechanical comparison of DHS® and Intertan nail®. Int Orthop. 2011;35:1695–701. doi:10.1007/s00264-010-1199-x.

    Article  PubMed Central  PubMed  Google Scholar 

  10. Muller M, Nazarian S, Koch P, Schatzker J. The comprehensive classification of fractures of long bones. Berlin: Springer-Verlag, 1990; doi:10.1007/978-3-642-61261-9.

  11. Mahoney FI, Barthel DW. Functional evaluation: the Barthel index. Md State Med J. 1965;14:61–5.

    CAS  PubMed  Google Scholar 

  12. Kraus M, Krischak G, Wiedmann K, Riepl C, Gebhard F, Jöckel JA, Scola A. Clinical evaluation of PFNA® and relationship between the tip-apex distance and mechanical failure. Unfallchirurg. 2011;114:470–8. doi:10.1007/s00113-011-1975-0.

    Article  CAS  PubMed  Google Scholar 

  13. Yaozeng X, Dechun G, Huilin Y, Guangming Z, Xianbin W. Comparative study of trochanteric fracture treated with the proximal femoral nail anti-rotation and the third generation of gamma nail. Injury. 2010;41:1234–8.

    Article  PubMed  Google Scholar 

  14. Singh M, Nagrath AR, Maini PS. Changes in trabecular pattern of the upper end of the femur as an index of osteoporosis. J Bone Joint Surg Am. 1970;52:457–67.

    CAS  PubMed  Google Scholar 

  15. Jongbloed L, Stacey S, Brighton C. Stroke rehabilitation: sensorimotor integrative treatment versus functional treatment. Am J Occup Ther. 1989;43:391–7.

    Article  CAS  PubMed  Google Scholar 

  16. Verhofstad MH, van der Werken C. DHS osteosynthesis for stable pertrochanteric femur fractures with a two-hole side plate. Injury. 2004;35:999–1002.

    Article  PubMed  Google Scholar 

  17. Ahrengart L, Törnkvist H, Fornander P, Thorngren KG, Pasanen L, Wahlström P, Honkonen S, Lindgren U. A randomized study of the compression hip screw and Gamma nail in 426 fractures. Clin Orthop Relat Res. 2002;401:209–22.

    Article  PubMed  Google Scholar 

  18. Utrilla AL, Reig JS, Muñoz FM, Tufanisco CB. Trochanteric gamma nail and compression hip screw for trochanteric fractures: a randomized, prospective, comparative study in 210 elderly patients with a new design of the gamma nail. J Orthop Trauma. 2005;19:229–33.

    Article  PubMed  Google Scholar 

  19. Schipper IB, Marti RK, van der Werken C. Unstable trochanteric femoral fractures: extramedullary or intramedullary fixation. Review of literature. Injury. 2004;35:142–51.

    Article  CAS  PubMed  Google Scholar 

  20. Wiss DA, Fleming CH, Matta JM, Clark D. Comminuted and rotationally unstable fractures of the femur treated with an interlocking nail. Clin Orthop Relat Res. 1986;212:35–47.

    PubMed  Google Scholar 

  21. Takigami I, Matsumoto K, Ohara A, Yamanaka K, Naganawa T, Ohashi M, Date K, Shimizu K. Treatment of trochanteric fractures with the PFNA (proximal femoral nail antirotation) nail system—report of early results. Bull NYU Hosp Jt Dis. 2008;66:276–9.

    PubMed  Google Scholar 

  22. Pires RE, Santana EO Jr, Santos LE, Giordano V, Balbachevsky D, Dos Reis FB. Failure of fixation of trochanteric femur fractures: clinical recommendations for avoiding Z-effect and reverse Z-effect type complications. Patient Saf Surg. 2011;5:17. doi:10.1186/1754-9493-5-17.

    Article  PubMed Central  PubMed  Google Scholar 

  23. Kouvidis GK, Sommers MB, Giannoudis PV, Katonis PG, Bottlang M. Comparison of migration behavior between single and dual lag screw implants for intertrochanteric fracture fixation. J Orthop Surg Res. 2009;4:16. doi:10.1186/1749-799X-4-16.

    Article  PubMed Central  PubMed  Google Scholar 

  24. Schipper IB, Bresina S, Wahl D, Linke B, Van Vugt AB, Schneider E. Biomechanical evaluation of the proximal femoral nail. Clin Orthop Relat Res. 2002;405:277–86.

    Article  PubMed  Google Scholar 

  25. Sahin S, Ertürer E, Oztürk I, Toker S, Seçkin F, Akman S. Radiographic and functional results of osteosynthesis using the proximal femoral nail antirotation (PFNA) in the treatment of unstable intertrochanteric femoral fractures. Acta Orthop Traumatol Turc. 2010;44:127–34. doi:10.3944/AOTT.2010.2237.

    Article  PubMed  Google Scholar 

Download references

Acknowledgments

E.M. is partly supported by the Centro Studi Achille e Linda Lorenzon at the Center for Geriatric Medicine.

Conflict of interest

M. Galli, V. Ciriello, L. Bocchino, N. M. Gangemi, M. Peruzzi and E. Marzetti declare that they have no conflict of interest.

Compliance with Ethics Guidelines

The study protocol was approved by the Catholic University’s Ethics Committee. Informed consent was obtained from all patients for being included in the study.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to E. Marzetti.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Galli, M., Ciriello, V., Bocchino, L. et al. Clinical and functional outcomes of internal fixation with intertrochanteric antegrade nail in older patients with proximal extracapsular femoral fractures. Eur J Trauma Emerg Surg 40, 495–500 (2014). https://doi.org/10.1007/s00068-013-0343-x

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00068-013-0343-x

Keywords

Navigation