Abstract
Plasma biochemistry parameters of 32 bluefin tuna were analyzed on two blood analyzer systems, VetTest 8008 and Olympus AU2700, and the results compared and correlated. Statistically significant differences (p<0.0001) between the two analyzers were found for the total cholesterol, triglyceride, and aspartate aminotransferase analytes, but not for those of glucose and total proteins, which demonstrated almost identical values and ranges on both analyzers (p = 0.383 and 0.188, respectively). The coefficients of variation were high for most parameters on both analyzers. Overall, we conclude that data obtained with both analyzers have the same clinical significance. In routine investigations on tuna blood, due to the relatively small numbers of available samples and small sample volumes, it is more likely that the bench-top dry-slide analyzer (VetTest 8008) will be the preferred analytical system to a high-volume primary analyzer (Olympus AU2700).
Similar content being viewed by others
References
Coz-Rakovac R, Strunjak-Perovic I, Topic Popovic N, Hacmanjek M, Simpraga M, Teskeredzic E (2002) Health status of wild and cultured sea bass in the northern Adriatic Sea. Vet Med Czech 47:222–226
Coz-Rakovac R, Strunjak-Perovic I, Hacmanjek M, Topic Popovic N, Lipej Z, Sostaric B (2005) Blood chemistry and histological properties of wild and cultured sea bass (Dicentrarchus labrax) in the North Adriatic Sea. Vet Res Commun 29:677–687
DiMagno EP, Corle D, Oȁ9Brien JF, Masnyk IJ, Go VL, Aamodt R (1989) Effect of long-term freezer storage, thawing, and refreezing on selected constituents of serum. Mayo Clin Proc 64:1226–1234
Edsall CC (1999) A blood chemistry profile for lake trout. J Aquat Anim Health 11:81–86
Horney B (1993) Clinical pathology of cold-water marine fishes. In: Stoskopf MK (ed) Fish medicine. WB Saunders, Philapelphia, pp 685–687
Little CJ, Gettinby G, Downs J, Marshall CB (1992) Consistency of results from the VetTest 8008 clinical biochemistry analyzer. Vet Rec 130:419–424
Tschudi PR (1995) Evaluation of the dry chemical analysis system VetTest 8008. Schweiz Arch Tierheilkd 136:381–385
Velisek J, Svobodova Z (2004a) Anaesthesia of rainbow trout (Oncorhynchus mykiss) with 2-phenoxyethanol: acute toxicity and biochemical blood profile. Acta Vet Brno 73:379–384
Velisek J, Svobodova Z (2004b) Anaesthesia of common carp (Cyprinus carpio L.) with 2-phenoxyethanol: acute toxicity and biochemical blood profile. Acta Vet Brno 73:247–252
Velisek J, Svobodova Z, Piackova V (2005) Effects of clove oil anaesthesia on rainbow trout (Oncorhynchus mykiss). Acta Vet Brno 74:139–146
Wells RMG, McIntyre RH, Morgan AK, Davie PS (1986) Physiological stress responses in big gamefish after capture: observations on plasma chemistry and blood factors. Comp Biochem Physiol 84:565–571
Acknowledgements
The authors wish to thank Mr. Mladen Milakovic, the owner of the tuna farm, and Mr. Goran Brstilo, the principal diver, for their help and assistance in providing tuna blood for this investigation.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Topic Popovic, N., Strunjak-Perovic, I., Coz-Rakovac, R. et al. Comparison of five tuna plasma analytes measured on two automated blood analyzers. Fish Physiol Biochem 32, 99–103 (2006). https://doi.org/10.1007/PL00021847
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/PL00021847