Total hip arthroplasty using an uncemented femoral component with taper design: outcome at 10-year follow-up

  • Original article
  • Published:
Archives of Orthopaedic and Trauma Surgery Aims and scope Submit manuscript

Abstract

The aim of this study was to assess the clinical and radiological outcome of the cementless-system (CLS) femoral component designed by Spotorno with a taper design. Ninety-four patients (107 hips) were operated on from January 1987 to December 1988. The female/male ratio was 2/1, the mean age was 51 years (range 20–77 years). Clinical follow-up was obtained in 89 hips (83%). Five patients (7 hips, 6.5%) could not be traced. Nine patients (11 hips, 10%) had died before the minimum time of follow-up required for this study (10 years). All these hips still had their stem in place at the time of the last intermediate inquiry. The mean follow-up was 10.3 ± 0.3 years. No stem required revision. According to the Harris score, 84% of hips were rated good or excellent, 14% fair, and 2% poor. The average Harris hip score was 88 at the time of the last follow-up. Fifteen patients (17%) reported occasional thigh pain. All patients reported complete relief of pain within the first 6 months after the operation. Radiologically, 95% of stems showed stable fixation by bony ingrowth, 5% by fibrous ingrowth. Seven (9%) uncemented acetabular components showed progressive migration. Three of those cups had been replaced in the meantime. Fifty-one (65%) of the CLS stems induced either no change in femoral bone density or only patchy loss of bone density localized to zone 1 or 7 according to Gruen, while 27 (35%) of the hips showed some reduction of bone density in the proximal diaphysis of the femur (zone 2 or 6). Severe progressive osteolysis of the femoral cortex underneath the lesser trochanter was found in 4 hips (5%) with coexistent loosening of the cup. In all of these hips, the Mecron cup had been used. At a mean follow-up of 10 years, the results of the CLS femoral component are comparable with those of modern techniques of cementing in primary total hip arthroplasty and with the long-term outcomes of other uncemented stems with tapered design. The long-term fixation of the cup remains an unsolved problem.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Author information

Authors and Affiliations

Authors

Additional information

Received: 14 August 1999

Rights and permissions

Reprints and permissions

About this article

Cite this article

Schramm, M., Keck, F., Hohmann, D. et al. Total hip arthroplasty using an uncemented femoral component with taper design: outcome at 10-year follow-up. Arch Orth Traum Surg 120, 407–412 (2000). https://doi.org/10.1007/PL00013771

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/PL00013771

Keywords

Navigation