Skip to main content
Log in

Ergometry for estimation of mechanical power output in sprinting in humans using a newly developed self-driven treadmill

  • ORIGINAL ARTICLE
  • Published:
European Journal of Applied Physiology Aims and scope Submit manuscript

Abstract

An evaluation of mechanical power during walking and running in humans was undertaken after developing a specially designed running ergometer (RE) in which the subjects gripped the handlebar in front of them keeping both arms straight and in a horizontal position. Ten subjects participated in comparisons of the mean horizontal pushing force (MF am) on the handlebar with the mean horizontal ground reaction force (MF fp) recorded by force platform under the RE during five different constant speeds of walking or running and sprint running with maximal effort. Mechanical power developed during sprint running on the RE was compared with a 50 m sprint. Mean linear velocity (Mv) of the RE belt was recorded by the rotary encoder attached to the axis of the belt. Mean mechanical power calculated from the handlebar setting (MP am=MF am × Mv) was compared to that calculated from force platform recordings (MP fp=MF fp × Mv). A high test-retest reproducibility was observed for both MF fp (r=0.889) and MF am (r=0.783). Larger values for the coefficient of variation for MF am (11.3%–15.8%) were observed than for MF fp (3.3%–8.2%). The MP am, which were obtained from five different constant speeds of walking, running and sprint running were closely correlated to those of MP fp (y=0.98x − 19.10,r=0.982, P < 0.001). In sprint running, MP am was 521.7 W (7.67 W · kg−1) and was correlated to the 50 m sprint time (r=−0.683, P < 0.01). It is concluded that the newly developed RE was useful in the estimation of mechanical power output during human locomotion such as when walking, jogging and sprinting.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Author information

Authors and Affiliations

Authors

Additional information

Accepted: 10 October 2000

Rights and permissions

Reprints and permissions

About this article

Cite this article

Funato, K., Yanagiya, T. & Fukunaga, T. Ergometry for estimation of mechanical power output in sprinting in humans using a newly developed self-driven treadmill. Eur J Appl Physiol 84, 169–173 (2001). https://doi.org/10.1007/PL00007955

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/PL00007955

Navigation