The influence of non-contact ultrasonic vibration on the solidification of gray and ductile irons has been evaluated with and without inoculation. Conventional instrumented cooling curve analysis samples were cast under a wide range of non-contact acoustic stimulation conditions. Ultrasonic frequencies between 17 and 18 kHz were evaluated at transducer power ratings of 1800–3600 Watts with various horn designs. The air gap between the ultrasonic actuator and the surface of the solidifying metal was varied from 11–38 mm. The resultant solidification cooling curves as well as the microstructure after solidification were evaluated. Ultrasonic treatment of gray irons resulted in only slight changes in graphite morphology. However, in some cases, ultrasonic treatment of uninoculated gray iron changed the graphite shape from undercooled type D graphite to type A graphite. Ductile irons subjected to ultrasonic treatment showed a slight increase in nodule count and nodularity. Also, ultrasonic treatments resulted in a minor increase in overall solidification time. Further work is needed to identify the specific non-contact acoustic conditions that will have a significant effect on cast iron solidification behavior.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Campbell J., “Effects of Vibration During Solidification,” International Metals Reviews, vol. 26, pp 71–108 (1981).

    Article  Google Scholar 

  2. Abramov V., Abramov O., Bulgakov V., and Sommer F., “Solidification of Aluminum Alloys under Ultrasonic Irradiation Using Water-Cooled Resonator,” Materials Letters, vol. 37, pp 27–34 (1998).

    Article  Google Scholar 

  3. Abromov O.V., “Action of High Intensity Ultrasound on Solidifying Metal,” Ultrasonics, vol. 25, pp 73–82 (Mar. 1987).

    Article  Google Scholar 

  4. Chernyshova N.V., Etelfes L.S., Zolotereva R.S., Yanovskaya E.I., “Influence of Vibration Treatment of Cast Iron on Glass Mold Performance,” Soviet Casting Technology, vol. 6, pp 14–15 (1989).

    Google Scholar 

  5. Gittus J.H., “Inoculation of Solidifying Iron and Steel Casting by Means of Vibration,” Journal of the Iron and Steel nstitute, vol. 192, pp 118–131 (June 1959).

    Google Scholar 

  6. Ohsawa Y., “Effect of Ultrasonic Vibration on Solidification Structures of Cast Irons,” NRIM Research Activities, vol. 67, pp 5–6 (1995).

    Google Scholar 

  7. ASM, “Cast Irons,” in Metals Handbook, vol. 1, Properties and Selection: Irons, Steels and High Performance Alloys, K. Mills, Ed., 9th ed. Metals Park, OH: ASM (2002).

    Google Scholar 

  8. Abramov O.V., Ultrasound in Liquid and Solid Metals. Boca Raton, FL: CRC Press, Inc. (1994).

    Google Scholar 

  9. Lynch P.C., “The Effects of Non-Contact Acoustic Vibrations on the Solidification and Microstructure of Aluminum Casting Alloy A356” (MS Thesis, Pennsylvania State University, 2007).

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Voigt, R., Lynch, P. & Grenko, T. Cast Iron Solidification with Non-Contact Acoustic Stimulation. Inter Metalcast 3, 79–86 (2009). https://doi.org/10.1007/BF03355461

Download citation

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF03355461

Keywords

Navigation