Skip to main content
Log in

The newly developed three-dimensional (3D) and two-dimensional (2D) thyroid ultrasound are strongly correlated, but 2D overestimates thyroid volume in the presence of nodules

  • Original Articles
  • Published:
Journal of Endocrinological Investigation Aims and scope Submit manuscript

Abstract

The newly developed three-dimensional (3D) and two-dimensional (2D) thyroid ultrasound (US) were compared in assessing thyroid volume (TV) in 104 patients: 53 had an isolated thyroid nodule, 32 toxic diffuse goiter, 17 non-toxic multi-nodular goiter, 1 toxic multinodular goiter and 1 a toxic adenoma. A real-time Technos apparatus (Esaote SpA, Italy) with a 7,5 MHz linear transducer was used. The volume of thyroid lobes by 2D was calculated according to the ellipsoid formula. In the same session, TV by 3D US was calculated using a probe tracking system (in vivo ScanNT Esaote 3.4 MedCom. Darmasdt) and software to reconstruct 3D images, directly giving the lobe volume. There was a very good agreement between 2D and 3D, but in 94/208 lobes with nodular lesions 2D showed a 10% systematic overestimation compared to 3D, the percentage error being higher in lobes with lower volumes. A possible explanation for this result is the inadequacy of the ellipsoid formula in forecasting the correct lobe profile in the presence of nodules. This intrinsic defect of 2D US should be taken into account when evaluating TV in patients with nodular goiter.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Subscribe and save

Springer+ Basic
$34.99 /Month
  • Get 10 units per month
  • Download Article/Chapter or eBook
  • 1 Unit = 1 Article or 1 Chapter
  • Cancel anytime
Subscribe now

Buy Now

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Fujimoto Y, Oka A, Omoto R, Hirose M. Ultrasound scanning of the thyroid gland as a new diagnostic approach. Ultrasonics 1967, 5: 177–80.

    Article  CAS  PubMed  Google Scholar 

  2. Marcocci C, Vitti P, Cetani F, Catalano F, Concetti R, Pinchera A. Thyroid ultrasonography helps to identify patients with diffuse lymphocytic thyroiditis who are prone to develop hypothyroidism. J Clin Endocrinol Metab 1991, 72: 209–13.

    Article  CAS  PubMed  Google Scholar 

  3. Vitti P, Rago T, Mancusi F, et al. Thyroid hypoechogenic pattern at ultrasonography as a tool for predicting recurrence of hyperthyroidism after medical treatment in patients with Graves’ disease. Acta Endocrinol (Copenh) 1992, 126: 128.

    CAS  Google Scholar 

  4. Rago T, Chiovato L, Grasso L, Pinchera A, Vitti P. Thyroid ultrasonography as a tool for detecting thyroid autoimmune diseases and predicting thyroid dysfunction in apparently healthy subjects. J Endocrinol Invest 2001, 24: 763–9.

    CAS  PubMed  Google Scholar 

  5. Gutenkust R, Hafermann W, Mansky T, Scriba PC. Ultrasonography related to clinical and laboratory findings in lymphocitic thyroiditis. Acta Endocrinol (Copenh) 1989, 121: 129.

    Google Scholar 

  6. Vitti P, Rago T, Mazzeo S, et al. Thyroid blood flow evaluation by color-flow doppler sonography distinguishes Graves’ disease from Hashimoto’s thyroiditis. J Endocrinol Invest 1995, 18: 857.

    CAS  PubMed  Google Scholar 

  7. Bogazzi F, Bartalena L, Brogioni S, et al. Color flow Doppler sonography rapidly differentiates type I and type II amiodar-one-induced thyrotoxicosis. Thyroid 1997, 7: 541.

    Article  CAS  PubMed  Google Scholar 

  8. Rago T, Vitti P, Chiovato L, et al. Role of conventional ultrasonography and color flow-Doppler sonography in predicting malignancy in “cold” thyroid nodules. Eur J Endocrinol 1998, 138: 41.

    Article  CAS  PubMed  Google Scholar 

  9. Tan GH, Gharib H. Thyroid incidentalomas: management approchesto non palpable nodules discovered incidentally on thyroid imaging. Ann Intern Med 1997, 126: 226.

    Article  CAS  PubMed  Google Scholar 

  10. Rago T, Chiovato L, Aghini-Lombardi F, Grasso L, Pinchera A, Vitti P. Non-palpable thyroid nodules in a borderline iodine-sufficient area: Detection by ultrasonography and follow-up. J Endocrinol Invest 2001, 24: 770–6.

    CAS  PubMed  Google Scholar 

  11. Vitti P, Rago T. Thyroid ultrasound as a predictor of thyroid disease. J Endocrinol Invest 2003, 26: 686–9.

    CAS  PubMed  Google Scholar 

  12. Brunn J, Blocjk U, Ruf J, Bos I, Kunze WP, Scriba PC. Volumetrie der schilddrusenlappen mittels eal-time-sonographie. Dtsch Med J 1986, 186: 1338–40.

    Google Scholar 

  13. Gutekunst R, Smolarek, Hasenpusch U, et al. Goitre epidemiology: thyroid volume, iodine excretion, thyroglobulin and thyrotropin in Germany and Sweden. Acta Endocrinol (Copenh) 1986, 11: 494–501.

    Google Scholar 

  14. Berghout A, Wiersinga WM, Smits NJ, Touber JL. The value of thyroid volume measured by ultrasonography in the diagnosis of goitre. Clin Endocrinol (Oxf) 1988, 28: 409–14.

    Article  CAS  Google Scholar 

  15. Tannahill AJ, Hooper MJ, England M, Ferriss JB, Wilson GM. Measurement of thyroid size by ultrasound, palpation and scintiscan. Clin Endocrinol (Oxf) 1978, 8: 483–6.

    Article  CAS  Google Scholar 

  16. Fenster A, Downey DB. Three-dimensional ultrasound imaging and its use in quantifying organ and pathology volumes. Anal Bioanal Chem 2003, 377: 982–9.

    Article  CAS  PubMed  Google Scholar 

  17. Sehgal CM, Broderick GA, Whittington R, Gornaik RJT, Arger PH. Three-dimensional US and volumetric assessment of the prostate. Radiology 1994, 192: 274–8.

    CAS  PubMed  Google Scholar 

  18. Tong S, Downey DB, Cardinal HN, Fenster A. A three-dimensional ultrasound prostate imaging system. Ultrasound Med Biol 1996, 22: 735–46.

    Article  CAS  PubMed  Google Scholar 

  19. Lyshchik A, Drozd V, Reiners C. Accuracy of three-dimensional ultrasound for thyroid volume measurement in children and adolescents. Thyroid 2004, 14: 2113–20.

    Article  Google Scholar 

  20. Hegedus L, Perrild H, Poulsen LR, et al. The determination ofthyroid volume by ultrasound and its relationship to body weight, age and sex in normal subjects. J Clin Endocrinol Metab 1983, 56: 260–3.

    Article  CAS  PubMed  Google Scholar 

  21. Rasmussen SN, Hjiorth L. Determination of thyroid volume by ultrasonic scanning. J Clin Ultrasound 1974, 2: 142–7.

    Article  Google Scholar 

  22. Altman DG, Goodman SN, Schroter S. How statistical expertise is used in medical research. JAMA 2002, 287: 2817–20.

    Article  PubMed  Google Scholar 

  23. Vitti P, Martino E, Aghini-Lombardi F, et al. Thyroid volume measurement by ultrasound in children as a tool for the assessment of mild iodine deficiency. J Clin Endocrinol Metab 1994, 79: 600–3.

    CAS  PubMed  Google Scholar 

  24. Bland MJ, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986, 8: 307–10.

    Article  Google Scholar 

  25. Aghini-Lombardi F, Antonangeli L, Pinchera A, et al. Effect of iodized salt on thyroid volume of children living in an area previously characterized by moderate iodine deficiency. J Clin Endocrinol Metab 1997, 82: 1136–9.

    CAS  PubMed  Google Scholar 

  26. Vitti P, Rago T. Thyroid volume in children: role of iodine intake. J Endocrinol Invest 2002, 25: 666–7.

    CAS  PubMed  Google Scholar 

  27. Delange F, Benker G, Caron PH, et al. Thyroid volume and urinary iodine in European schoolchildren: standardization of values for assessment of iodine deficiency. Eur J Endocrinol 1997, 136: 180–7.

    Article  CAS  PubMed  Google Scholar 

  28. Zimmermann MB, Hess S. Molinari L, et al. New reference values for thyroid volume by ultrasound in iodine sufficient schoolchildren: a World Health Organization and Nutrition for Health and Development Iodine Deficiency study Group Report. Am J Clin Nutr 2004, 79: 213–7.

    Google Scholar 

  29. Zimmermann MB. New WHO reference criteria for thyroid volume by ultrasound. American Society for nutritional science. 2004, 1675.

  30. WHO, UNICEF and ICCIDD. Indicators for assessing iodine deficiency disorders and their control through salt iodization. WHO/NUT/94.6 1994. Geneve.

  31. Elliot TL, Downey DB, Tong S, McLean CA, Fenster A. Accuracy of prostate volume measurements in vitro using three-dimensional ultrasound. Acad Radiol 1996, 3: 401–6.

    Article  CAS  PubMed  Google Scholar 

  32. Tong S, Cardinal HN, McLoughlin RF, Downey DB, Fenster A. Intra- and inter-observer variability and reliability of prostate volume measurement via two-dimensional and three-dimensional ultrasound imaging. Ultrasound Med Biol 1998, 24: 673–81.

    Article  CAS  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to P. Vitti.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Rago, T., Bencivelli, W., Scutari, M. et al. The newly developed three-dimensional (3D) and two-dimensional (2D) thyroid ultrasound are strongly correlated, but 2D overestimates thyroid volume in the presence of nodules. J Endocrinol Invest 29, 423–426 (2006). https://doi.org/10.1007/BF03344125

Download citation

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF03344125

Key-words

Navigation