Skip to main content
Log in

Investigation of Watergas Welded Joints for Future Decisions Concerning Old Hydropower Stations

  • Peer-Reviewed Section
  • Published:
Welding in the World Aims and scope Submit manuscript

Abstract

After 60 years of service the watergas welded shaft of Kaprun hydropower plant was dismantled. In this work the results of the investigation of this weld are presented. Additionally to strength, hardness and toughness values obtained from standard small scale samples, some integral samples including welding flaws and inhomogenities were tested to verify the fracture mechanical assessment of the shaft. As an overall result it can be reported that the joint itself shows excellent behaviour similar to the base material as long as it is free of defects.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Die Verfahren der Schweißtechnik (Processes in Welding Technique), Fachbuchreihe Schweißtechnik, DVS -Verlag, Band 55, Düsseldorf, 1974, p. 1.12.

  2. Cerjak H.: Vorgehen bei der Sicherheitsbeurteilung älterer Druckrohrleitungen aus Stahl von Wasserkraftanlagen (Safety assessment of old steel shafts of hydropower plants), ÖZE, Jg. 44, Heft 2, 1991, pp. 34–43.

    Google Scholar 

  3. Enzinger N., Heber S.J., Gubeljak N., Mayrhuber J., Cerjak H.: Properties of a watergas welded hydropower shaft: a look in the past for a easier life in future, SAIW’s 60th Anniversary Conference — Gold Reef City, Johannesburg, 28th and 29th May 2008.

  4. Bergmann U., Böhmert J., Viehring H.W.: Bestimmung bruchmechanischer Kennwerte an Reaktordruckbehälterstählen mit der Einproben-Compliance-Methode und Korrelation zur Kerbschlagarbeit (Determination of fracture mechanics properties on steels for nuclear pressure vessels by one sample compliance method and correlation with impact toughness values), Herg.: Forschungszentrum Rossendorf e.V., Dresden, 1995.

  5. ASTM E1820–99a: Standard test method for measurement of fracture toughness, American Society for Testing and Materials, Philadelphia, 1999.

  6. Roos E., Eisele U., Silcher H.: Effect of stress state on the ductile fracture behavior of large scale specimens, in: E.M. Hackett, K.H. Schwalbe, R.H. Dodds (Eds.): ASTM STP 1171, American Society for Testing and Materials, Philadelphia, 1993, pp. 41–63.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Enzinger, N., Heber, S.J., Cerjak, H. et al. Investigation of Watergas Welded Joints for Future Decisions Concerning Old Hydropower Stations. Weld World 53, R52–R56 (2009). https://doi.org/10.1007/BF03266703

Download citation

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF03266703

IIW-Thesaurus keywords

Navigation