ICRU Publication 24,Determination of Absorbed Dose in a Patient Irradiated by Beams of X or Gamma Rays in Radiotherapy Procedures, 1976.
Kutcher, G.J., Coia, L. and Gillin, M.,Comprehensive QA for radiation oncology: Report of AAPM Radiation Therapy Committee Task Group 40. Med Phys; 21:581–618, 1994.
Article
CAS
PubMed
Google Scholar
Noel, A., Aletti, P. and Bey, P.,Detection of errors in individual patients in radiotherapy by systematic in vivo dosimetry. Radiother Oncol; 34:144–151, 1995.
Article
CAS
PubMed
Google Scholar
Akselrod, M.S., Kortov, V.S., Kravetsky, D.J., and Gotlib, V.I.,Highly sensitive thermoluminescent anion-defect α-Al
2
O
3:C single crystal detectors. Radiat. Prot. Dosim. 33, pp119–122, 1990.
CAS
Google Scholar
Aksekrod, M.S., Kortov, V.S. and Gorelova, E.A.,Preparation and properties of α-Al
2
O
3:C, Radiat. Prot. Dosim. 33, pp159–164, 1993.
Google Scholar
McKeever, S.W.W., Moscovitch, M. and Townsend, P.D.,Thermoluminescence Dosimetry Materials: Properties and Uses. Nuclear Technology Publishing, Ashford, UK. 1995.
Google Scholar
Botter-Jensen, L. and McKeever, S.W.S.,Optically stimulated luminescence dosimetry using natural and synthetic materials.Radiat. Prot. Dosi. Vol. 65, pp. 273–280, 1996.
CAS
Google Scholar
McKeever, S.W.S., Akselrod, M.S. and Markey, B.G.,Pulsed optically stimulated luminescence dosimetry using α-Al
2
O
3:C.
Radiat. Prot. Dosi. Vol. 65, pp. 267–272, 1996.
CAS
Google Scholar
Antonov-Romanovskii, V.V., Kcium-Marcus, I.F., Poroshina, M.S. and Trapeznikova, A.Z.,Conference of the Academy of Sciences if the USSR on the Peachful Uses of Atomic Energy, Moscow, 1955. USAEC Report AEC-tr-2435 (Pt. 1), 239, 1956.
Brăuulich, P., Schăfer, D. and Scharmann, A.,A simple model for thermoluminescence and thermalJly stimulated conductivity of inorganic photoconducting phosphors and experiments pertaining to infra-red stimulated luminescence. Proceedings of the First Internation Conference on Luminescene Dosimetry. Stanford, June 1965, USAEC, 57-73, 1967.
Sanboren, E.N. and Beard, E. L.,Sulfides of strontium, calcium, and magnesium in infra-red stimulated luminescence dosimetry. Proceedings of the First International Conference on Luminescence Dosimetry. Stanford, June, 1965. USAEC, 183-191, 1967.
Yukihara, E.G., and Mckeever, S.W.S.,Optically stimulated luminescence (OSL) dosimetry in medicine, Phys. Med. Biol. 53, R351-R379, 2008.
Article
CAS
PubMed
Google Scholar
Perks, CA., Roy, G.Le., and Prugnaud, B.,Introduction of the InLight Monitoring Service, Rad. Prot. Dosi., 220-223, 2007.
Jursinic, Paul A.,Characterization of optically stimulated luminescent dosimeters, OSLDs for clinical dosimetric measurement, Med. Phys. 34(12), 4594–4604, 2007.
Article
PubMed
Google Scholar
Viamonte, A., da Rosa, L.A.R., Buckley, L.A., Cherpak, A. and Cygler, J.E.,Radiotherapy dosimetry using a commercial OSL system, 1261–1266, Med. Phys. 35(4), April, 2008.
Article
CAS
PubMed
Google Scholar
Miller, S.D. and Murphy, M.K.,Technical performance of the Luxel Al
2
O
3:C Optically Stimulated Luminescence Dosemeter Element at Radiation Oncology and Nuclear Accident Dose Levels, Rad. Prot. Dosi., 123, 435–442, 2007.
Article
CAS
Google Scholar
Aznar, M.C., Andersen, C.E., Botter-Jensen, L., Back, S.A.J., Mattsson, S., Kjær-Kristoffersen, F. and Medin, J.,Real-time optical-fibre luminescence dosimetry for radiotherapy: physical characteristics and applications in photon beams. Phys. Med. Biol. 49, 1655–1669, 2004.
Article
PubMed
Google Scholar
Schembri, V. and Heijmen, B.J.M.,Optically stimulated luminescence (OSL) of carbon-doped aluminum oxide(Al
2
O
3:C) for film dosimetry in radiotherapy, Med. Phys. 34(6), 2113–2118, 2007.
Article
CAS
PubMed
Google Scholar
Yukihara, E.G., Whiletly, V.H., McKeever, S.W.S., Akselrod, A.E. and Akselrod, M.S.,Effect of high-dose irradiation on the optically stimulated luminescence of Al
2
O
3:C, Rad. Meas. 38, 317–330, 2004.
Article
CAS
Google Scholar
Edmund, J.M., Anderson, C.E., Marckmann, C.J., Aznar, M.C., Akselrod, M.S., and Bℝtter-Jensen, L.,CW-OSL Measurement protocols using optical fibre Al
2
O
3:C dosimeters, Rad. Prot. Dosi. 368-374, 2006.