As presentation of medical radiographic images on soft-copy displays (cathode ray tubes) becomes increasingly prevalent in electronic radiography, methods of quality assurance must be developed to ensure that radiologists can effectively transfer film-based reading skills. Luminance measurements provide the basis for evaluating the state of soft-copy displays. An integrated approach has been implemented at Mallinckrodt Institute of Radiology (MIR, Washington University, St Louis, MO) that facilitates measurement of geographically distributed soft-copy displays with centralized data logging, performance tracking, and calibration. MIR's central radiology image manager exercises the display station that drives the monitor, harvests the measurement data, stores the results, and submits the resulting data for additional processing. The luminance measurements are collected by a small, portable, photometric instrument designed at MIR that includes a serial port that is accessed via local area terminal service supported by the radiology image manager. The design details of the photometric instrument and example luminance characteristics of several soft-copy displays used at MIR are presented in this report.
Article PDF
Similar content being viewed by others
Avoid common mistakes on your manuscript.
References
Cox JR, Muka E. Blaine GJ, et al: Considerations in Moving Electronic Radiography into Routine Use. IEEE J Selected Areas in Comm, 1992 (in press)
Cox JR, Moore SM, Whitman RA, et al: Rapid display of radiographic IMAGES. SPIE 1446:40–51, 1991
Davros WJ, Gaskil JW, Mun SK: Quality assurance for image display devices in a hospital-wide IMACS network. SPIE 1091:301–304, 1989
Blume H, Roehrig H, Browne M, et al: Comparison of the physical performance of high resolution CRT displays and films recorded by laser image printers and displayed on light-boxes and the need for a display standard. SPIE 1232:11–28, 1990
Roehrig H, Ji TL, Browne M, et al: Signal-to-noise ratio and maximum information control images displayed by a CRT. SPIE 1232:115–133, 1990
Roehrig H, Dallas WJ, Ji TL, et al: Physical evaluation of CRT's for use in digital radiography. SPIE 1091:262–278, 1989
Texas Instruments: Optoelectronics and Image Sensors. Data book, 1990
Watson J: Optoelectronics. England, Van Nostrand Reinhold, 1988
Seippel RG: Optoelectronics for Technology and Engineering. New Jersey, Prentice Hall, 1989
United Detector Technology: PIN Series-Planar Diffused Silicon Photodiodes. Data sheets, 1989
Oriel Corporation: Light Sources, Monochromators, Detection Systems, Catalog, 1989
Tannas LE: Flat Panel Displays and CRTs. England, Van Nostrand Reinhold, 1985
RCA, Electro-Optics Handbook. New Jersey, RCA, 1974
Bloom S, Wayne S: High-resolution A/D applications and methods proliferate, Electronics Products Magazine, December 12, 1984
Author information
Authors and Affiliations
Additional information
Supported in part by the Kodak Health Sciences Division.
Reprinted with permission from Medical Imaging VI: Picture Archiving and Communications Systems, Society of Photo-Optical Instrumentation Engineers, 1992.
Rights and permissions
About this article
Cite this article
Reiker, G.G., Gohel, N., Muka, E. et al. Quality monitoring of soft-copy displays for medical radiography. J Digit Imaging 5, 161–167 (1992). https://doi.org/10.1007/BF03167765
Issue Date:
DOI: https://doi.org/10.1007/BF03167765