Abstract
The interleaved-spiral magnetic resonance imaging (MRI) technique was implemented and optimized on a Bruker Biospec 47/30 scanner. The method gives rise to high-resolution images with a time saving factor of up to 8, as compared to the conventional approach. A multifunctional pulse sequence for the fast interleaved-spiral MRI was composed. These functions include spin intensity imaging, transverse relaxation timeT 2 and apparent diffusion-weighted imaging. The method was used to obtain the dynamic responses of a rat brain during ischemia.
Similar content being viewed by others
References
Haase A., Frahm J., Matthaei D., Hanicke W., Merboldt K.D.: J. Magn. Reson.67, 258–266 (1986)
Hennig J., Nauerth A., Friedburg H.: Magn. Reson. Med.3, 823–833 (1986)
Mansfield P.: J. Phys. C Solid State Phys.10, L55 (1997)
Ljunggren S.: J. Magn. Reson.54, 338–343 (1983)
Ahn C.B., Kim J.H., Cho Z.H.: IEEE Trans. Med. Imaging5, 2–7 (1986)
Meyer C.H., Hu B.S., Nishimura D.G., Macoski A.: Magn. Reson. Med.28, 202–213 (1992)
Keegan J., Gatehouse P., Yang G.Z., Firmin D.: Magn. Reson. Med.43, 787–792 (2000)
Hardy C.J., Zhao L., Zong X., Saranathan M., Yucel E.K.: Magn. Reson. Imaging17, 170–176 (2003)
Oesterle C., Hennel F., Hennig J.: Magn. Reson. Imaging19, 1333–1337 (2001)
Stafford R.J., Hazle J.D., Glover G.H.: Magn. Reson. Med.43, 909–912 (2000)
Meyer C.H., Hu B.S., Nishmura D.G., Macovski A.: Magn. Reson. Med.28, 202–213 (1992)
Foltz W.D., Al-Kwifi O., Sussman M.S., Stainsby J.A., Wright G.A.: Magn. Reson. Med.49, 1089–1097 (2003)
Lai S., Glover G.H.: Magn. Reson. Med.39, 68–78 (1998)
Nayak K.S., Tsai C.M., Meyer C.H., Nishimura D.G.: Magn. Reson. Med.45, 521–524 (2001)
Ahunbay E.: Magn. Reson. Med.44, 491 (2000)
Lu G., Liu M.L., Li L.Y., Ye C.H.: Chin. Phys. Lett.19, 1385–1388 (2002)
Lu G., Liu M.L., Li L.Y., Ye C.H.: Prog. Nat. Sci.12, 691–696 (2002)
Lu G., Liu M.L., Ye C.H.: Chin. J. Magn. Reson. (in press)
Hardy C.J., Cline H.E.: J. Appl. Phys.66, 1513–1516 (1989)
Bornert P., Aldefeld B., Eggers H.: Magn. Reson. Med.44, 479–484 (2000)
Noll D.C., Pauly J.M., Meyer C.H., Nishimura D.G., Macovski A.: Magn. Reson. Med.25, 319–333 (1992)
Man Lai-Chee, Pauly J.M., Macovski A.: Magn. Reson. Med.37, 906–913 (1997)
Ahunbay E., Pipe J.G.: Magn. Reson. Med.44, 491–494 (2000)
O’Sullivan J.D.: IEEE Trans. Med. Imaging4, 200–207 (1985)
Jackson J.I., Meyer C.H., Nishimura D.G., Macovski A.: IEEE Trans. Med. Imaging10, 473–478 (1991)
Longa E.Z., Weinstein P.R., Carlson S., Cummin R.: Stroke20, 84 (1989)
Kohno K., Back T., Hoehn-Berlage M., Hossmann K.-A.: Magn. Reson. Imaging13, 65–71 (1995)
Besselmann M., Liu M., Diedenhofen M., Franke C., Hoehn M.: NMR Biomed.14, 289–296 (2001)
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Lu, G., Liu, M.L. & Ye, C.H. Fast and high-resolution MRI on the basis of interleaved-spiral technique at 4.7 T and its application for imaging of ischemic rat brain. Appl. Magn. Reson. 25, 313–321 (2003). https://doi.org/10.1007/BF03166692
Received:
Revised:
Issue Date:
DOI: https://doi.org/10.1007/BF03166692