Abstract
A high-field continuous-wave (CW) and pulse electron paramagnetic resonance spectrometer operating at 122 and 244 GHz is described. The instrument is based on a millimeter-wave bridge built from quasi-optical components. To improve the sensitivity, a cryo-cooled detector/mixer is used. The magnetic field is generated using a cryogen-free superconducting 12 T magnet (warm bore, 88 mm) equipped with a helium-flow cryostat for sample cooling. The advantages of this spectrometer are described and first results (obtained in CW mode) on different types of samples at 122 and 244 GHz are presented. The extensions to pulse operation as well as double resonance techniques (electron-electron and electron-nuclear) are briefly discussed.
Similar content being viewed by others
References
Eaton S.S., Eaton G.R.: Appl. Magn Reson.16, 159–160 (1999)
Möbius K.: Appl. Magn. Reson.21, 255 (2001)
Grinberg O.Y., Berliner L.J. (eds.): Very High Frequency (VHF) ESR/EPR. Biological Magnetic Resonance, vol. 22. New York: Kluwer Academic Plenum 2004.
Lubitz W., Möbius K., Dinse K.P.: Magn. Reson. Chem.43, S2-S3 (2005)
Smith G.M., Riedi P.C. in: Electron Paramagnetic Resonance, vol. 17, pp. 164–204. Specialist Perodical Reports. London: Royal Society of Chemistry 2000.
Smirnov A.I., Smirnova T.I., MacArthur R.L., Good J.A., Hall R.: Rev. Sci. Instrum.77, 035108 (2006)
Mansoorabadi S.O., Seravalli J., Furdui C., Krymov V., Gerfen G.J., Begley T.P., Melnick J., Ragsdale S.W., Reed G.H.: Biochemistry45, 7122–7131 (2006)
Bennati M., Farrar C.T., Bryant J.A., Inati S.J., Weis V., Gerfen G.J., Riggs-Gelasco P., Stubbe J., Griffin R.G.: J. Magn. Reson.138, 232–243 (1999)
Weis V., Bennati M., Rosay M., Bryant J.A., Griffin R.G.: J. Magn. Reson.140, 293–299 (1999)
Hertel M.M., Denysenkov V.P., Bennati M., Prisner T.F.: Magn. Reson. Chem.43, S248-S255 (2005)
Blok H., Disselhorst J.A.J.M., Orlinskii S.B., Schmidt J.: J. Magn. Reson.166, 92–99 (2004)
Blok H., Disselhorst J.A.J.M., van der Meer H., Orlinskii S.B., Schmidt J.: J. Magn. Reson.173, 49–53 (2005)
Fuchs M.R., Prisner T.F., Möbius K.: Rev. Sci. Instrum.70, 3681–3683 (1999)
Grishin Y.A., Fuchs M.R., Schnegg A., Dubinskii A.A., Dumesh B.S., Rusin F.S., Bratman V.L., Möbius K.: Rev. Sci. Instrum.75, 2926–2936 (2004)
Feher G.: Phys. Rev.103, 834–835 (1956)
Schweiger A., Jeschke G.: Principles of Pulse Electron Paramagnetic Resonance. New York: Oxford University Press 2001.
Epel B., Gromov I., Stoll S., Schweiger A., Goldfarb D.: Concepts Magn. Reson. Part B: Magn. Reson. Eng.26, 36–45 (2005)
Feher E.R.: Phys. Rev. A: Gen. Phys.136, A145-A157 (1964)
Chiesa M., Paganini M.C., Giamello E., Murphy D.M.: Res. Chem. Intermed.28, 205–214 (2002)
Burghaus O., Rohrer M., Gotzinger T., Plato M., Möbius K.: Meas. Sci. Technol.3 765–774 (1992)
Lebedev Y.S. in: Modern Pulsed and Continuous-Wave Electron Spin Resonance (Kevan L., Bowman M.K., eds.), pp. 365–404. New York: Wiley 1989.
Eklund H., Uhlin U., Farnegardh M., Logan D.T., Nordlund P.: Prog. Biophys. Mol. Biol.77, 177–268 (2001)
Sjöberg B.M.: Struct. Bonding88, 139–173 (1997)
Schmidt P.P., Rova U., Katterle B., Thelander L., Gräslund A.: J. Biol. Chem.273, 21463–21472 (1998)
Andersson K.K., Schmidt P.P., Katterle B., Strand K.R., Palmer A.E., Lee S.K., Solomon E.I., Gräslund A., Barra A.L.: J. Biol. Inorg. Chem.8, 235–247 (2003)
Hanson M.A., Schmidt P.P., Strand K.R., Gräslund A., Solomon E.I., Andersson K.K.: J. Am. Chem. Soc.121, 6755–6756 (1999)
Schmidt P.P., Andersson K.K., Barra A.L., Thelander L., Gräslund A.: J. Biol. Chem.271, 23615–23618 (1996)
van Dam P.J., Willems J.P., Schmidt P.P., Potsch S., Barra A.L., Hagen W.R., Hoffman B.M., Andersson K.K., Gräslund A.: J. Am. Chem. Soc.120, 5080–5085 (1998)
Un S.: Magn. Reson. Chem.43, S229-S236 (2005)
Gerfen G.J., Bellew B.F., Un S., Bollinger J.M., Stubbe J., Griffin R.G., Singel D.J.: J. Am. Chem. Soc.115, 6420–6421 (1993)
Hoganson C.W., Sahlin M., Sjöberg B.M., Babcock G.T.: J. Am. Chem. Soc.118, 4672–4679 (1996)
Hogbom M., Galander M., Andersson M., Kolberg M., Hofbauer W., Lassmann G. Nordlund P., Lendzian F.: Proc. Natl. Acad. Sci. USA100, 3209–3214 (2003)
Hagedoorn P.L., Schmidt P.P., Andersson K.K., Hagen W.R., Flatmark T., Martinez A.: J. Biol. Chem.276, 22850–22856 (2001)
Brausam A., van Eldik R.: Inorg. Chem.43, 5351–5359 (2004)
Neese F., Solomon E.I.: J. Am. Chem. Soc.120, 12829–12848 (1998)
Meier R., Heinemann F.W.: Inorg. Chim. Acta337, 317–327 (2002)
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Reijerse, E., Schmidt, P.P., Klihm, G. et al. A CW and pulse EPR spectrometer operating at 122 and 244 GHz using a quasi-optical bridge and a cryogen-free 12 T superconducting magnet. Appl. Magn. Reson. 31, 611–626 (2007). https://doi.org/10.1007/BF03166606
Received:
Revised:
Issue Date:
DOI: https://doi.org/10.1007/BF03166606