Abstract
The paper presents a summary of investigations, which were performed with two mediumsize Plasma-Focus (PF) facilities, operated at IPJ in Swierk, Poland, during the recent few years. Attention is paid to experiments performed with MAJA-PF and PF-360 devices. which were run within the energy range from 37 kJ to 170 kJ. To analyze the emitted electron beams (e-beams) and X-rays, the use was made of different time-integrated and time-resolved diagnostic techniques, e.g. Cerenkov detectors, magnetic analyzers, vacuum X-ray pinhole cameras and scintillation detectors. A qualitative and quantitative analysis of the obtained results has been performed. The correlation of relativistic e-beams and X-ray pulses with other PF phenomena has also been discussed.
Similar content being viewed by others
References
M. J. Bernstein: Phys. Fluids13 (1970) 2858.
J. W. Mather:Methods of Experimental Physics. (Ed: H. Griem, R. Lovberg), Academic Press, New York, Vol. 9, Pt.B, (1971) 187.
W. H. Bostick, V. Nardi, W. Prior: J. Plasma Phys.8 (1972) 7.
P. Choi: inProc. 3rd Int. Conf. Dense Z-Pinches, London, 1993, AIP, New York, 1994, 288.
L. Jakubowski, M. J. Sadowski: Brazilian J. Phys.,32 (2002) 187.
R. Lebert et al.: inProc. 4th Int. Conf. Dense Z-Pinches, Vancouver, Canada, 1997, (Ed: N. R. Pereira, J. Davis, P. E. Pulsifer) AIP, New York, 1997, vol.409, 291.
S. Lee et al.: in Proc. 1998 ICPP and 25th EPS CCF-PP, Prague, Czech Rep., 1998, ECA, 1998, Vol. 22C, 2591.
L. Jakubowski, M. Sadowski, J. Zebrowski: Nuclear Fusion41, No 6 (2001) 755.
M. Sadowski: J. Moscow Phys. Soc.8 (1998) 197.
L. Jakubowski, M. Sadowski, J. Zebrowski: J. Technics Phys.38 (1997) 141.
M. Sadowski, J. Zebrowski: High Temp. Material Processes6 (2002) 1.
M. Scholz et al.: Czech. J. Phys. 52, Suppl. D (2002) D100.
J. Zebrowski, J. Baranowski, L. Jakubowski, M. J. Sadowski, J. Stanislawski: Probl. of Atomic Sci. and Techn., Series: Plasma Physics6 (2000) 91.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Zebrowski, J., Sadowski, M.J. & Jakubowski, L. Studies of electron beams and X-Rays within different plasma-focus devices. Czech. J. Phys. 54 (Suppl 3), C256 (2004). https://doi.org/10.1007/BF03166410
Received: